Class Ⅰ Electronic Analytical Balance 120g 0.1mg ATOMFAIR®

$934.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Class Ⅰ analytical balance with 120 g capacity, 0.1 mg readability, isoCAL internal calibration, ±0.2 mg repeatability and RS232 output. Order now.

SKU: AF-EI-B-ANLB-120A-IR52
Category:
Tags:
Brands:

ATOMFAIR® EB120G-0.1MG-I-02 ELECTRONIC ANALYTICAL BALANCE

(Class Ⅰ Metrology Grade | isoCAL Auto Internal Calibration)

CLASS Ⅰ PRECISION METROLOGY

Product Overview

The ATOMFAIR® EB120G-0.1MG-I-02 is a Class Ⅰ certified precision metrology analytical balance, purpose-built for formal laboratory metrology verification, traceable quality inspection and micro-powder quantitative analysis. Equipped with a built-in isoCAL fully automatic internal calibration system and high-precision electromagnetic force restoration sensor, it delivers 120 g maximum weighing capacity, 0.1 mg readability and ±0.2 mg typical repeatability, with strict linearity control within ±0.2 mg. It integrates proprietary thermal temperature compensation algorithms to suppress ambient temperature drift, features a dedicated filter membrane weighing mode optimized for trace sample detection, and comes with a 210 mm high internal weighing chamber and standard RS232 communication interface for data transmission. This model complies with official metrology inspection specifications and is widely deployed in national metrology institutes, third-party testing laboratories and research facilities requiring formal calibration traceability.

EB120G-0.1MG-I-02 Detailed Technical Parameters

PARAMETER ITEM UNIT TECHNICAL SPECIFICATION DETAILS
Product Model EB120G-0.1MG-I-02
Product Classification Electronic Analytical Balance
Readability (d) mg 0.1
Maximum Capacity (Max) g 120
Typical Repeatability Error mg ±0.2
Typical Linearity Error mg ±0.2
Average Response Time s ≤2.5
Initial Warm-up Duration min 30~60
Accuracy Class Class Ⅰ
Physical Dimensions (L × W × H) mm 210 × 310 × 315
Weighing Pan Dimensions mm Φ90
Chamber Internal Height mm 210
Operating Ambient Temp °C 18~23
Operating Ambient Humidity 20%~80% RH (Non-condensing Matrix)
Power Supply Configuration Input: 220V AC / 50Hz; Output: 12V/2A
Communication Baud Rate 300, 600, 1200, 2400, 4800, 9600

ES-J Series Comprehensive Model Parameter Family

PARAMETER ITEM UNIT EB120G-0.1MG-I-02 EB220G-0.1MG-I-03 EB120G-0.1MG-I-03 EB220G-0.1MG-I-04
Readability (d) mg 0.1 0.1 0.1 0.1
Maximum Capacity (Max) g 120 220 120 220
Typical Repeatability Error mg ±0.2 ±0.2 ±0.2 ±0.2
Typical Linearity Error mg ±0.2 ±0.2 ±0.2 ±0.2
Average Response Time s ≤2.5
Initial Warm-up Duration min 30~60
Accuracy Class Class Ⅰ
Physical Form Dimensions mm 210 × 310 × 315 (L × W × H)
Pan Size / Chamber Height mm Φ90 Spatial Platform / 210mm Internal Chamber Vertical Height
Operating Atmospheric Matrix 18~23°C Thermal Scope / 20%~80% RH Non-condensing Conditions
Power Supply Profile Input: 220V AC / 50Hz; Output: 12V/2A Stable Direct Current
Communication Interface Standard Protocol Baud Rates: 300, 600, 1200, 2400, 4800, 9600

Universal Optional Accessories Catalog

ACCESSORY DESCRIPTION COMPATIBILITY SUPPORT STATUS
Portable Micro Dot-Matrix Printer Fully Supported (Optional Configuration Link)
USB to Serial Port Adapter Cable Fully Supported (Optional Configuration Link)
Under-hook Weighing Mechanism Device Fully Supported (Optional Configuration Link)
Solid & Liquid Dual-use Density Metrology Kit Fully Supported (Optional Configuration Link)

Key Features & Core Advantages

  • Advanced isoCAL Auto-Calibration: Integrates a fully automated internal calibration alignment system (available for internal calibration specific models) executing seamless calibration loops for reliable accuracy.
  • Standardized RS232 Data Pipeline: Equipped with industrial standard RS232 interaction protocol nodes for direct PC peripheral connectivity and automatic matched printer synchronization.
  • Thermal Temperature Compensation: Built-in proprietary environmental thermal balance algorithms, eliminating background drift triggered by temperature variants to maintain validation purity.
  • Filter Membrane Weighing Mode: Specialized internal electronic filtering parameters optimized for ultra-precise mass detection regarding low-mass or trace membrane samples.
  • High-Definition Lucid LCD Screen: Minimalist and responsive operating control deck combined with deep visibility segments for quick data extraction.

APPLICATION SCOPE: Premium laboratory metrology, micro-powder analysis, dual-density evaluation, and peripheral system data logging.
PACKAGING: Shockproof industrial grade dual-layer foam protection inserts with sealed structural enclosures and customized universal adapter assemblies.
IMPORTANT NOTICE: To sustain ideal Class Ⅰ performance parameters, preheat the assembly for 30~60 minutes within the 18~23°C regulated workspace. Prevent fluid condensations inside the non-condensing 20%~80% RH atmospheric matrix during data capture loops.
TAILORED METROLOGY FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This balance requires a 30-60 minute warm-up period and operation within 18-23°C and 20-80% RH non-condensing to maintain Class I accuracy. The isoCAL auto-calibration system must be regularly utilized to ensure traceable measurement compliance.

  • Operating Temperature Range: Maintain ambient temperature between 18°C and 23°C during all measurement operations.
  • Operating Humidity Range: Maintain relative humidity between 20% and 80% in a non-condensing environment.
  • Warm-up Duration: Allow the balance to warm up for 30 to 60 minutes after powering on before conducting measurements.
  • Calibration Requirement: Perform calibration using the integrated isoCAL system at regular intervals to sustain metrological accuracy.
  • Power Supply Stability: Connect the balance to a stable 220V AC/50Hz power source through the provided adapter.

Follow these steps to ensure accurate and reliable weighing results with the EB120G balance. Proper warm-up, environmental control, and calibration are critical for Class I metrology.

Required Equipment: Electronic analytical balance, isoCAL auto-calibration system, Power adapter and RS232 cable (optional)

  1. Warm Up the Balance
    Warm up the balance for 30 to 60 minutes after connecting the power supply to stabilize internal components.
  2. Confirm Environmental Conditions
    Confirm that the ambient temperature is 18-23°C and relative humidity is 20%-80% non-condensing before starting measurements.
  3. Initiate isoCAL Calibration
    Initiate the isoCAL auto-calibration sequence to verify and adjust the balance's accuracy.
  4. Select Weighing Mode
    Select the filter membrane weighing mode from the interface when measuring low-mass or trace samples.

How does the isoCAL auto-internal calibration system on the EB120G-0.1MG-I-02 maintain Class I accuracy under ambient temperature drift?

The built-in isoCAL system executes seamless automated calibration loops using a high-precision electromagnetic force restoration sensor, eliminating the need for external mass standards. This is reinforced by proprietary thermal temperature compensation algorithms that suppress background drift caused by temperature variants within the specified 18–23°C operating range, ensuring the ±0.2 mg repeatability and linearity are maintained without manual intervention.

Can the EB120G-0.1MG-I-02 be integrated with a printer or PC for traceable data logging in a regulated laboratory?

Yes, the balance includes a standard RS232 communication interface supporting baud rates from 300 to 9600, enabling direct connection to a PC or an optional portable micro dot-matrix printer. This allows automated data transmission for formal metrology verification and traceable quality inspection workflows, as required in national metrology institutes and third-party testing labs.

What are the critical preheating and environmental requirements to achieve the specified 0.1 mg readability on the EB120G-0.1MG-I-02?

To sustain Class I performance, the balance requires an initial warm-up of 30–60 minutes in a regulated workspace maintained at 18–23°C with non-condensing humidity between 20% and 80% RH. The 210 mm internal chamber height and Φ90 mm weighing pan support stable micro-powder analysis, but fluid condensation must be prevented during data capture loops to avoid compromising the ±0.2 mg repeatability.

The ATOMFAIR EB120G-0.1MG-I-02 is a Class I analytical balance with 120g capacity and 0.1mg readability, featuring isoCAL auto internal calibration and thermal compensation for stable laboratory metrology.

Positive

  • isoCAL auto internal calibration: Fully automated internal calibration system eliminates dependence on external calibration weights, simplifying routine accuracy verification and reducing operator intervention.
  • Thermal temperature compensation: Proprietary ambient drift suppression algorithms maintain measurement stability across fluctuating thermal conditions, enhancing reproducibility in unregulated lab environments.

Trade-offs

  • Extended warm-up and environmental limits: Requires 30–60 minute preheat and strict 18–23°C, 20–80% RH non-condensing conditions to achieve Class I metrology performance, limiting quick-start utility in unconditioned spaces.
  • Legacy RS232 interface: Standard RS232 communication port may require optional USB adapter for direct connectivity with modern laboratory PCs and data systems lacking serial ports.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).