Analytical Semi-Micro Balance 31/120g 0.01mg ATOMFAIR®

$1,058.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Dual-range analytical semi-micro balance with 31/120 g capacity, 0.01/0.1 mg readability, internal isbl calibration, RS232, and ≤5 s stabilization. Order now.

SKU: AF-EI-B-SMBL-120U-IR04
Category:
Brands:

ATOMFAIR® EB31G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB31G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The ATOMFAIR® EB31G-01MG-R-02 is a high-performance analytical & semi-micro balance configured for High-accuracy industrial laboratory analysis, analytical chemistry, with 31 g maximum capacity and 0.01 mg readability. It delivers ±0.02 mg repeatability, ±0.02 mg linearity, isbl fully automatic internal calibration.
Built with a rear-mounted electromagnetic force restoration sensor, it supports precision weighing control for the stated measurement range. Its calibration configuration is isbl fully automatic internal calibration, supporting the calibration workflow for this model. The stated stabilization performance is ≤5 seconds, giving the operator a defined response-time reference before recording measurements.
Its split-body structural architecture and panoramic transparent glass draft shield help support stable weighing performance. Built-in operating functions include multi-unit conversion. The communication configuration includes a standard RS232 communication interface. The stated application scope covers High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.

EB31G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 31 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

This balance requires a 30 to 60 minute warm-up after power-on to achieve thermal stability before zeroing or calibration. Operation must be within 10°C to 33°C and 20% to 80% RH to maintain specified repeatability and linearity.

  • Warm-Up Requirement: Allow the balance to warm up for 30 to 60 minutes following power engagement before performing any operational zeroing, calibration, or sample addition.
  • Environmental Conditions: Maintain the operating environment within 10°C to 33°C temperature and 20% to 80% relative humidity.
  • Calibration Trigger: The isbl internal calibration executes automatically when ambient temperature fluctuates by ≥1.5°C or after 2 hours of use.
  • Stabilization Time: Wait for the balance to achieve a stabilization time of ≤5 seconds before recording a measurement.
  • Draft Shield Use: Close the panoramic glass draft shield during weighing to isolate the sample from air currents and vibrations.

Use the following steps to prepare and operate the balance for accurate weighing. The procedure ensures compliance with the specified warm-up, calibration, and environmental constraints.

Required Equipment: Draft shield, Internal calibration system

  1. Warm-up
    Allow the balance to warm up for 30 to 60 minutes after power-on before performing any zeroing, calibration, or sample addition.
  2. Condition check
    Verify that the operating environment is within 10°C to 33°C and 20% to 80% relative humidity.
  3. Calibrate
    Execute the internal automated calibration using the isbl system after the warm-up period.
  4. Stabilize
    Wait for the stabilization indicator to confirm the reading is stable within ≤5 seconds.
  5. Sample placement
    Place the sample centrally on the weighing pan and close the draft shield to prevent air currents.

What is the practical difference between the two readability ranges (0.01 mg and 0.1 mg) on the EB31G-01MG-R-02 balance, and when should each be used?

The EB31G-01MG-R-02 offers dual-range readability: 0.01 mg up to 31 g and 0.1 mg up to 120 g. Use the 0.01 mg range for high-precision analytical chemistry requiring microgram-level resolution, and switch to the 0.1 mg range when weighing larger samples up to 120 g where lower resolution is acceptable. Repeatability and linearity are ±0.02 mg in the fine range and ±0.1 mg in the coarse range, as specified in the product's specification matrix.

Can the EB31G-01MG-R-02 balance be integrated with external data systems for automated data logging?

Yes, the balance includes a standard RS232 communication interface for bidirectional data transfer to micro-printers or host computer terminals, enabling automated data logging and paperless compliance tracking. Its split-body structural architecture also allows flexible placement of the detached control display unit to minimize hand-induced micro-vibrations during integration.

What are the required warm-up and environmental conditions for accurate operation of the EB31G-01MG-R-02 balance?

The balance requires a mandatory preheating period of 30–60 minutes after power-on before performing zeroing, internal calibration, or sample addition. It operates reliably in ambient temperatures of 10°C–33°C and humidity of 20%–80% RH. The autonomous internal calibration system automatically activates if ambient temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours.

The ATOMFAIR EB31G-01MG-R-02 is a 31 g / 120 g dual-range analytical balance with 0.01 mg / 0.1 mg readability, featuring fully automatic internal calibration and a rear-mounted electromagnetic force sensor. It requires a 30–60 minute warm-up and operates within 10–33°C and 20–80% RH.

Positive

  • Dual-range readability and capacity: The balance offers 0.01 mg / 0.1 mg readability and 31 g / 120 g maximum capacity, enabling both micro and semi-micro weighing within a single instrument.
  • Fully automatic internal calibration: The isbl system automatically recalibrates when ambient temperature changes by ≥1.5°C or after 2 hours, ensuring sustained accuracy without manual intervention.

Trade-offs

  • Mandatory warm-up period: A 30–60 minute preheating interval is required after power-on before accurate zeroing, calibration, or sample measurement can be performed.
  • Controlled environment requirements: The balance must operate within 10–33°C and 20–80% RH, necessitating a climate-controlled laboratory to maintain specified performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).