Analytical Balance EB220G-1MG 220 g × 1 mg ATOMFAIR®

$1,314.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Touchscreen analytical balance with 220 g capacity, 1 mg readability, ±1 mg repeatability, ±2 mg linearity, Φ90 mm pan and RS232 output. Order now.

SKU: AF-EI-B-ANLB-220M-IR77
Category:
Tags:
Brands:

ATOMFAIR® EB220G-1MG TOUCHSCREEN ELECTRONIC ANALYTICAL BALANCE

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® EB220G-1MG is a high-performance analytical balance configured for Analytical laboratory weight verification, institutional metrology, with 220 g maximum capacity and 1 mg readability. It delivers ±1 mg repeatability, ±2 mg linearity, internal calibration.
Its calibration configuration is internal calibration, supporting the calibration workflow for this model. The weighing hardware information includes pan size 90 mm.
The communication configuration includes a standard RS232 communication interface. The stated application scope covers Analytical laboratory weight verification, institutional metrology, SCI-grade material R&D.

EB220G-1MG Exclusive Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Maximum Capacity 220 g
Readability 1 mg
Repeatability ±1 mg
Linearity ±2 mg
Pan Size Φ90 mm
Calibration Type External Calibration Model


Full Series Configuration Matrix

Model EB120G-0.1MG-01 EB120G-0.1MG-I-01 EB220G-0.1MG-01 EB220G-0.1MG-I-01 EB220G-1MG EB220G-1MG-I EB320G-1MG EB320G-1MG-I EB520G-1MG-01 EB520G-1MG-I
Max Capacity (g) 120 120 220 220 220 220 320 320 520 520
Readability (mg) 0.1 0.1 0.1 0.1 1 1 1 1 1 1
Repeatability (mg) ±0.1 ±0.1 ±0.1 ±0.1 ±1 ±1 ±1 ±1 ±1 ±1
Linearity (mg) ±0.2 ±0.2 ±0.2 ±0.2 ±2 ±2 ±2 ±2 ±2 ±2
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90
Calib. Type External Internal External Internal External Internal External Internal External Internal
* Note: “C” suffix denotes Automated Internal Calibration systems; Standard models utilize External Calibration architectures. Processed under strict ISO 9001 compliance conditions.


Key Features & Advantages

  • TFT Full-Color Touch Interface: High-resolution true color liquid crystal display paired with double-glove sensitive touch operation maps perfectly to ergonomic laboratory environments.
  • Dual Metro Anti-Fatigue UI: Specifically engineered utilizing eco-friendly, optimized contrast matrices to reduce eye strain during extended verification campaigns.
  • Heavy-Duty Stabilized Chassis: Full aluminum architectural base dampens environmental low-frequency vibration, promoting uncompromised validation integrity.
  • Industrial Structural Safeguards: Equipped with premium display protective covers and structural glass-door transit shock locks to extend long-term system life-cycles.
  • Integrated Application Software: Factory preloaded with specialized metrology workflows and standard RS232 digital output ports for bi-directional data transfer to PCs and printers.

APPLICATION SCOPE: Analytical laboratory weight verification, institutional metrology, SCI-grade material R&D, and data validation metrics.
PACKAGING: Secure high-density foam container enclosure integrated with glass-door protection travel locks.
IMPORTANT NOTICE: This metrology system is highly sensitive to micro-gravitational drift. Ensure transit glass locks are completely disengaged before initiation, and calibrate within an isolated environment to maintain uncompromised performance.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

The balance is highly sensitive to micro-gravitational drift and requires an isolated, vibration-free environment for accurate weighing. Transit glass locks must be disengaged before use, and external calibration is necessary prior to each measurement campaign.

  • Micro-Gravitational Drift Sensitivity: The system is sensitive to micro-gravitational drift and must be placed in an isolated environment to maintain performance.
  • Transit Lock Disengagement: Transit glass locks must be completely disengaged before initiating the balance to prevent damage and ensure accurate operation.
  • External Calibration Requirement: External calibration is required, and the calibration procedure must be performed in an isolated environment to ensure uncompromised performance.

What are the implications of the EB220G-1MG's 1 mg readability and external calibration for analytical weight verification compared to higher-resolution internal calibration models?

The EB220G-1MG offers 1 mg readability with ±1 mg repeatability and ±2 mg linearity, suitable for standard analytical weight verification. Its external calibration requires manual calibration weights, whereas internal calibration models (e.g., EB220G-0.1MG-I) provide automated recalibration. For applications demanding 0.1 mg resolution, higher-readability variants from the same series are recommended.

What communication interfaces does the EB220G-1MG provide for data integration in laboratory information systems?

The EB220G-1MG includes a standard RS232 communication interface for bi-directional data transfer to PCs and printers, as stated in the product overview. This enables direct integration with laboratory data management systems for weight recording and traceability.

What precautions are necessary when setting up the EB220G-1MG balance to ensure accurate measurements?

The balance is highly sensitive to micro-gravitational drift. Before use, ensure transit glass locks are completely disengaged, and calibrate within an isolated environment to maintain performance. The heavy-duty aluminum chassis dampens low-frequency vibration, but proper leveling and stable bench placement are essential.

The Atomfair EB220G-1MG analytical balance provides 220 g capacity with 1 mg readability and external calibration, featuring a TFT touch interface and vibration-damping aluminum chassis, but requires careful environmental isolation and manual calibration for reliable operation.

Positive

  • Vibration-Damping Aluminum Chassis: The heavy-duty stabilized chassis with full aluminum architectural base dampens environmental low-frequency vibration, promoting measurement integrity in analytical weighing applications.
  • Double-Glove Sensitive Touch Interface: The TFT full-color touch display with double-glove sensitivity enables ergonomic operation in laboratory environments where users wear protective gloves, reducing eye strain and improving workflow efficiency.

Trade-offs

  • External Calibration Requirement: This model relies on external calibration weights rather than automated internal calibration, requiring manual calibration procedures and additional calibration equipment for accurate measurement.
  • Micro-Gravitational Drift Sensitivity: The balance is highly sensitive to micro-gravitational drift; it must be calibrated in an isolated environment and transit glass locks must be fully disengaged before use to maintain performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).