ATOMFAIR® EB200G-0.1MG-01 HIGH-PRECISION ANALYTICAL BALANCE

LABORATORY INSTRUMENT GRADE

Product Overview

The ATOMFAIR® EB200G-0.1MG-01 is a high-performance analytical balance configured for Trace quantitative chemistry analysis, solid-state cell boundary validation, with 200 g maximum capacity and 0.1 mg readability. It delivers ±0.1 mg repeatability, ±0.2 mg linearity, automatic zero-tracking calibration.
Its calibration configuration is automatic zero-tracking calibration, supporting the calibration workflow for this model. The weighing hardware information includes pan size 90 mm.
Its glass draft shield supports stable weighing performance. Built-in operating functions include piece counting, percentage weighing, multi-unit conversion. The stated application scope covers Trace quantitative chemistry analysis, solid-state cell boundary validation, precise material science workflows.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Metrology Design (EB200G-0.1MG-01 Exclusive)
Product Model EB200G-0.1MG-01
Maximum Capacity 200 g
Readability 0.1 mg (0.0001 g)
Repeatability ±0.1 mg
Linearity Error ±0.2 mg
Pan Size Φ90 mm

Key Features & Advantages

  • Premium Industrial Ergonomics: Highly resilient, corrosion-proof, and impact-resistant ABS engineering plastic chassis structure balances structural stability with lightweight laboratory relocation.
  • Advanced Cross-Current Blockers: Features an integrated four-sided transparent glass draft shield, aluminum alloy backplate, and an specialized under-pan airflow breeze shield to fully secure the analytical chamber.
  • Vibration Suppression Architecture: Solid full-aluminum base foundation actively eliminates ambient parasitic low-frequency vibrations, complemented by 4-level anti-shock adaptation and tunable response metrics speeds.
  • Versatile Operational Capabilities: Supports dual-mode piece counting, percentage metric weighing, direct universal multi-unit conversions (g, oz, ct), and a built-in internal below-balance underhook setup.
  • Total Mechanism Security Safeguards: Mechanical glass door transport lock, display screen protective dust guard, automatic zero-tracking calibration, and smart fault diagnostics guarantee robust operational longevity.


2. FA Series Full Analytical Matrix Parameters
Model EB100G-0.1MG EB110G-0.1MG EB160G-0.1MG EB200G-0.1MG-01 EB210G-0.1MG-02 EB60G-0.1MG-R EB120G-0.1MG-03 EB220G-0.1MG-03 EB320G-0.1MG-02
Max Cap (g) 100 110 160 200 210 60/210 120 220 320
Readability (mg) 0.1 0.1 0.1 0.1 0.1 0.1/1 0.1 0.1 0.1
Repeat (mg) ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1/±1 ±0.1 ±0.1 ±0.1
Linear (mg) ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 ±0.2/±2 ±0.2 ±0.2 ±0.2
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90

APPLICATION SCOPE: Trace quantitative chemistry analysis, solid-state cell boundary validation, precise material science workflows, and micro-sample auditing.
PACKAGING: Shock-absorbent industrial shipping enclosure paired with integrated glass transit locks and dust protective covers.
IMPORTANT NOTICE: This 0.1mg sub-milligram metrology balance must be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation. Never move the device without activating the glass door transport security mechanism.
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

This balance requires leveling on an anti-vibration stone table and pre-warming before operation to ensure measurement accuracy. The device must never be moved without activating the glass door transport lock to prevent damage to the internal mechanism.

  • Leveling on anti-vibration table: The balance must be placed on a stable, anti-vibration stone table and leveled using the adjustable feet before use.
  • Pre-warming requirement: The balance must be pre-warmed according to the manufacturer's specifications to stabilize internal components and achieve accurate readings.
  • Transport lock activation: The mechanical glass door transport lock must be engaged before any movement of the balance to secure the weighing chamber.
  • Draft shield operation: The four-sided glass draft shield must be fully closed during weighing to minimize air currents and ensure stability.

Follow these steps to properly level, pre-warm, and secure the balance for accurate weighing. These procedures ensure reliable performance and prevent damage to the instrument.

Required Equipment: Anti-vibration stone table

  1. Level the balance
    Place the balance on an anti-vibration stone table and adjust the leveling feet until the bubble indicator shows level.
  2. Pre-warm the balance
    Connect the balance to power and allow it to pre-warm for the recommended duration specified in the manual.
  3. Engage transport lock
    Activate the glass door transport lock mechanism before attempting to move the balance to a different location.
  4. Close draft shield
    Ensure all four glass panels of the draft shield are closed during weighing to block air currents.

How does the 0.1 mg readability of the EB200G-0.1MG-01 balance affect its suitability for trace quantitative chemistry analysis?

The 0.1 mg readability (0.0001 g) enables precise measurements for trace analysis. With ±0.1 mg repeatability and ±0.2 mg linearity, it supports reliable quantification of small mass changes in solid-state cell boundary validation and micro-sample auditing.

What environmental and setup conditions are required for accurate operation of the EB200G-0.1MG-01 analytical balance?

The balance must be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation. Its integrated four-sided transparent glass draft shield, aluminum alloy backplate, and under-pan airflow breeze shield protect against air currents, while the solid full-aluminum base foundation suppresses ambient parasitic low-frequency vibrations.

What precautions must be taken when moving or transporting the EB200G-0.1MG-01 analytical balance?

Never move the device without activating the glass door transport security mechanism. The balance includes a mechanical glass door transport lock and display screen protective dust guard. It is shipped in a shock-absorbent industrial enclosure with integrated glass transit locks and dust covers to ensure safe relocation.

The ATOMFAIR EB200G-0.1MG-01 analytical balance delivers 0.1 mg readability with ±0.1 mg repeatability and ±0.2 mg linearity, supported by a four-sided glass draft shield and full-aluminum vibration-suppression base, making it suitable for trace quantitative chemistry and solid-state cell boundary validation. Operational constraints include mandatory leveling on an anti-vibration stone table and pre-warming before use, with a transport lock required to prevent damage during relocation.

Positive

  • Sub-milligram precision with draft shield: 0.1 mg readability and ±0.1 mg repeatability, combined with a four-sided glass draft shield and under-pan breeze shield, ensure stable weighing in trace chemistry and solid-state cell boundary validation workflows.
  • Vibration suppression and transport security: A full-aluminum base with 4-level anti-shock adaptation dampens ambient low-frequency vibrations, while a mechanical glass door transport lock protects the mechanism during laboratory relocation.

Trade-offs

  • Requires anti-vibration stone table: The balance must be completely leveled on an anti-vibration stone table to achieve specified repeatability and linearity, adding infrastructure requirements for deployment.
  • Pre-warming and transport lock mandatory: Pre-warming according to specifications is required before operation, and the glass door transport lock must be engaged during any movement to prevent damage, imposing procedural constraints.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).