ATOMFAIR® EB200G-0.1MG-01 HIGH-PRECISION ANALYTICAL BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This balance requires leveling on an anti-vibration stone table and pre-warming before operation to ensure measurement accuracy. The device must never be moved without activating the glass door transport lock to prevent damage to the internal mechanism.
- Leveling on anti-vibration table: The balance must be placed on a stable, anti-vibration stone table and leveled using the adjustable feet before use.
- Pre-warming requirement: The balance must be pre-warmed according to the manufacturer's specifications to stabilize internal components and achieve accurate readings.
- Transport lock activation: The mechanical glass door transport lock must be engaged before any movement of the balance to secure the weighing chamber.
- Draft shield operation: The four-sided glass draft shield must be fully closed during weighing to minimize air currents and ensure stability.
Follow these steps to properly level, pre-warm, and secure the balance for accurate weighing. These procedures ensure reliable performance and prevent damage to the instrument.
Required Equipment: Anti-vibration stone table
- Level the balance
Place the balance on an anti-vibration stone table and adjust the leveling feet until the bubble indicator shows level. - Pre-warm the balance
Connect the balance to power and allow it to pre-warm for the recommended duration specified in the manual. - Engage transport lock
Activate the glass door transport lock mechanism before attempting to move the balance to a different location. - Close draft shield
Ensure all four glass panels of the draft shield are closed during weighing to block air currents.
How does the 0.1 mg readability of the EB200G-0.1MG-01 balance affect its suitability for trace quantitative chemistry analysis?
The 0.1 mg readability (0.0001 g) enables precise measurements for trace analysis. With ±0.1 mg repeatability and ±0.2 mg linearity, it supports reliable quantification of small mass changes in solid-state cell boundary validation and micro-sample auditing.
What environmental and setup conditions are required for accurate operation of the EB200G-0.1MG-01 analytical balance?
The balance must be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation. Its integrated four-sided transparent glass draft shield, aluminum alloy backplate, and under-pan airflow breeze shield protect against air currents, while the solid full-aluminum base foundation suppresses ambient parasitic low-frequency vibrations.
What precautions must be taken when moving or transporting the EB200G-0.1MG-01 analytical balance?
Never move the device without activating the glass door transport security mechanism. The balance includes a mechanical glass door transport lock and display screen protective dust guard. It is shipped in a shock-absorbent industrial enclosure with integrated glass transit locks and dust covers to ensure safe relocation.
The ATOMFAIR EB200G-0.1MG-01 analytical balance delivers 0.1 mg readability with ±0.1 mg repeatability and ±0.2 mg linearity, supported by a four-sided glass draft shield and full-aluminum vibration-suppression base, making it suitable for trace quantitative chemistry and solid-state cell boundary validation. Operational constraints include mandatory leveling on an anti-vibration stone table and pre-warming before use, with a transport lock required to prevent damage during relocation.
Positive
- Sub-milligram precision with draft shield: 0.1 mg readability and ±0.1 mg repeatability, combined with a four-sided glass draft shield and under-pan breeze shield, ensure stable weighing in trace chemistry and solid-state cell boundary validation workflows.
- Vibration suppression and transport security: A full-aluminum base with 4-level anti-shock adaptation dampens ambient low-frequency vibrations, while a mechanical glass door transport lock protects the mechanism during laboratory relocation.
Trade-offs
- Requires anti-vibration stone table: The balance must be completely leveled on an anti-vibration stone table to achieve specified repeatability and linearity, adding infrastructure requirements for deployment.
- Pre-warming and transport lock mandatory: Pre-warming according to specifications is required before operation, and the glass door transport lock must be engaged during any movement to prevent damage, imposing procedural constraints.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).