ATOMFAIR® EB220G-0.1MG-I-04 ELECTRONIC ANALYTICAL BALANCECLASS Ⅰ PRECISION METROLOGY
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires a 30 to 60 minute warm-up period within an 18 to 23°C regulated workspace. Operation must be maintained under non-condensing conditions at 20% to 80% relative humidity to prevent measurement drift.
- Warm-up Duration: Allow the balance to warm up for 30 to 60 minutes after power-on before performing measurements.
- Operating Temperature Range: Maintain the ambient temperature between 18°C and 23°C during operation.
- Humidity Range: Keep relative humidity within 20% to 80% and ensure non-condensing conditions.
- Condensation Prevention: Prevent fluid condensation inside the weighing chamber during data capture.
- Workspace Requirements: Operate the balance in a regulated, draft-free laboratory environment.
This procedure outlines the warm-up, calibration, and measurement steps required for Class I precision weighing. Follow these steps to ensure accurate and repeatable mass measurements.
Required Equipment: ATOMFAIR EB220G-0.1MG-I-04 Analytical Balance
- Power On and Warm Up
Power on the balance and allow it to warm up for 30 to 60 minutes before use. - Confirm Environmental Conditions
Confirm that the ambient temperature is between 18°C and 23°C and relative humidity is between 20% and 80% non-condensing. - Perform Automatic Calibration
Initiate the isoCAL automatic internal calibration cycle to ensure measurement accuracy. - Select Weighing Mode
Select the appropriate weighing mode, such as standard or filter membrane mode, via the control panel. - Place Sample and Record Reading
Place the sample on the pan and record the stable reading after the typical response time of ≤2.5 seconds. - Transfer Data
Transfer measurement data via the RS232 interface to a connected PC or printer if required.
What is the impact of temperature fluctuations on the EB220G-0.1MG-I-04's measurement accuracy, and how does the thermal compensation mitigate it?
The ATOMFAIR EB220G-0.1MG-I-04 is designed for a regulated operating ambient temperature of 18–23°C to sustain Class I precision. It incorporates a built-in proprietary environmental thermal balance algorithm that eliminates background drift triggered by temperature variants, maintaining validation purity during measurements.
Can the EB220G-0.1MG-I-04 be integrated with a PC for automated data logging?
Yes, the balance is equipped with a standard RS232 communication interface supporting baud rates from 300 to 9600, allowing direct PC connectivity. An optional USB to serial port adapter cable is available for modern computer compatibility, enabling automated data capture and printer synchronization.
What are the required preheating and environmental conditions to maintain Class I accuracy on the EB220G-0.1MG-I-04?
To sustain Class I performance, the balance requires an initial warm-up duration of 30–60 minutes within a regulated workspace of 18–23°C and 20%–80% RH non-condensing conditions. These parameters ensure the electromagnetic force restoration sensor and isoCAL calibration system operate within specification.
The ATOMFAIR EB220G-0.1MG-I-04 is a Class I analytical balance with 220 g capacity and 0.1 mg readability, featuring isoCAL automatic internal calibration and electromagnetic force restoration sensor for precision metrology in micro-powder and density analysis applications.
Positive
- isoCAL Automatic Internal Calibration: Integrates a fully automated internal calibration system that executes seamless calibration loops to maintain reliable accuracy without manual intervention.
- Filter Membrane Weighing Mode: Specialized electronic filtering parameters optimized for ultra-precise mass detection of low-mass or trace membrane samples, enhancing measurement stability.
Trade-offs
- Extended Warm-Up Requirement: Requires 30–60 minutes preheating within a regulated 18–23°C workspace to sustain Class I performance, delaying immediate use.
- Non-Condensing Humidity Constraint: Operates only within 20%–80% RH non-condensing conditions; condensation can disrupt measurements and must be strictly avoided.