Molybdenum Evaporation Boat Set, Non Splash Type, Oval Tub, 0.1 x 10 x 100 mm
Product Type: Evaporation Boat Set
Research-grade laboratory product
|
||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
|
LABORATORY PROCUREMENT SUPPORT
For model selection, accessory matching, platform compatibility or configuration confirmation, contact our technical sales team.
E-MAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
This document defines the operational constraints for the Molybdenum Evaporation Boat Set (SKU AF-BM-L-EVBT-0117-VAR). It is intended for use in vacuum evaporation processes only, with strict adherence to electrical and thermal limits.
- Electrical Rating Constraint: Operate the boat only within the specified electrical rating of 1.95 V, 78 A, and 152 W to prevent resistive overheating and premature failure.
- Maximum Temperature Constraint: Do not exceed the maximum rated temperature of 1400 °C, as this can cause material degradation or structural failure of the boat.
- Vacuum Environment Requirement: Use the boat exclusively in a vacuum evaporation system to prevent oxidation and ensure stable resistive heating performance.
This procedure outlines the safe installation and operation of the Molybdenum Evaporation Boat Set in a vacuum evaporation system. Follow these steps to ensure proper mounting, electrical connection, and thermal management.
Required Equipment: Vacuum evaporation system, Resistive-heating power supply, Evaporation source holder
- Inspect the boat
Inspect the molybdenum boat for any visible damage or deformation before installation. - Mount the boat
Mount the boat securely into the evaporation source holder, ensuring proper alignment and contact. - Connect the power supply
Connect the power supply leads to the boat terminals, verifying correct polarity and tight connections. - Set the power parameters
Set the power supply to the specified voltage, current, and power limits (1.95 V, 78 A, 152 W) before energizing. - Evacuate the chamber
Evacuate the vacuum chamber to the required base pressure before applying power to the boat. - Ramp up temperature gradually
Ramp up the boat temperature gradually to the desired evaporation temperature, not exceeding 1400 °C. - Monitor the evaporation process
Monitor the evaporation process continuously, adjusting power as needed to maintain stable deposition conditions.
How does the 0.5 cc tub capacity and 1400 °C maximum temperature of this molybdenum evaporation boat set influence its use in high-temperature vacuum evaporation processes?
The 0.5 cc tub capacity defines the maximum source loading volume, while the 1400 °C maximum temperature sets the upper limit for evaporation processes. The specified electrical ratings (1.95 V, 78 A, 152 W) must be matched to the power supply to achieve the required evaporation rate without exceeding the boat's thermal limits.
What critical dimensional and geometric parameters must be verified when integrating this molybdenum evaporation boat set with an existing evaporation source holder?
The boat has overall dimensions of 0.1 mm thickness, 10 mm width, and 100 mm length, with an oval tub geometry featuring a 40 mm tub length, 2.5 mm tub depth, and 0.5 cc capacity. The configuration details (upper part 0.10, middle part 0.05, bottom part 0.10) are part of the selection information to ensure proper mating with the holder.
What electrical and infrastructural requirements must be met to operate this molybdenum evaporation boat set safely?
The boat is rated for 1.95 V, 78 A, and 152 W, so the power supply must be capable of delivering these values. Additionally, the maximum temperature of 1400 °C requires appropriate thermal management within the vacuum system. Confirm that the boat's dimensions and geometry match the source holder to avoid overheating or arcing.
This Molybdenum evaporation boat set with non-splash oval tub geometry (0.1x10x100 mm, 0.5 cc capacity) is designed for resistive-heating vacuum evaporation up to 1400°C, requiring careful matching with source holder and power supply parameters.
Positive
- Non-splash oval tub geometry: The oval tub with variable wall thickness (upper 0.10, middle 0.05, bottom 0.10 mm) is designed to reduce splashing during evaporation, enabling cleaner deposition in vacuum processes.
- Defined electrical and dimensional specs: Explicit voltage (1.95 V), current (78 A), and power (152 W) ratings, along with precise 0.1x10x100 mm dimensions, allow direct matching with compatible power supplies and source holders for reliable operation.
Trade-offs
- Limited maximum temperature 1400°C: The 1400°C maximum temperature rating constrains use to evaporation processes that do not require higher temperatures; processes exceeding this limit are incompatible.
- Requires careful compatibility verification: Boat material, dimensions, tub geometry, and electrical ratings must be confirmed against the specific evaporation source holder and power supply before ordering, adding a pre-purchase engineering step.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).