This document outlines the critical constraints for safe operation of the tungsten evaporation boat. Adherence to these constraints prevents damage to the boat and ensures consistent evaporation performance.
- Vacuum Environment: The boat must be operated only within a vacuum chamber to prevent oxidation and ensure proper resistive heating.
- Electrical Matching: The power supply must be configured to match the boat's voltage, current, and power ratings to prevent overheating or underpowering.
- Temperature Limit: Do not exceed the maximum temperature rating of 1200°C to avoid material degradation and failure.
- Contamination Control: Handle the boat with clean gloves to avoid introducing contaminants that could affect evaporation purity.
- Mechanical Integrity: Inspect the boat for cracks or deformation before each use to prevent electrical shorts or breakage.
This procedure describes the chronological steps for installing and operating the tungsten evaporation boat in a vacuum evaporation system. Follow these steps to achieve safe and reproducible evaporation runs.
Required Equipment: Vacuum evaporation system, Power supply, Clean gloves
- Inspect the boat
Inspect the tungsten boat for any visible damage, cracks, or contamination before installation. - Mount the boat
Mount the boat securely in the evaporation source holder, ensuring proper electrical contact. - Connect the power leads
Connect the power supply leads to the boat terminals, verifying the polarity and tightness. - Evacuate the chamber
Evacuate the vacuum chamber to the required base pressure before applying power. - Apply power gradually
Apply power gradually to the boat, monitoring the temperature and current to avoid thermal shock. - Monitor the evaporation
Monitor the evaporation process to ensure the boat temperature remains within the safe operating range. - Cool down and vent
Cool down the boat completely before venting the chamber and removing the boat.
What are the electrical and thermal limits of the Atomfair tungsten evaporation boat AF-EBWB-S0208X80T40D25C12FL?
The boat is rated at 1.47 V, 204 A, and 300 W, with a maximum operating temperature of 1200 °C. These values must be matched to your resistive-heating power supply and process temperature requirements before installation.
How do I verify that this straight-type flat-tub tungsten boat fits my evaporation source holder?
Confirm the boat's overall dimensions (0.2 mm thickness, 8 mm width, 80 mm length) and tub geometry (40 mm tub length, 2.5 mm depth, 1.2 cc capacity) against your source holder's mating dimensions. The flat-tub configuration is a key selection criterion for proper seating and source loading.
What package quantities are available for this tungsten evaporation boat and what is the minimum order?
The minimum order quantity is 5 pieces, with package options of 5 or 10 pieces per pack. Choose the package size that aligns with your evaporation run planning and inventory needs.
This tungsten evaporation boat (straight type, flat tub, 0.2x8x80 mm) provides a defined geometry and electrical rating (1.47 V, 204 A, 300 W) for resistive-heating deposition, with a maximum temperature of 1200°C and a tub capacity of 1.2 cc, but requires precise matching with the power supply and source holder.
Positive
- Tungsten construction for high-temperature operation: The tungsten material supports resistive heating up to 1200°C, enabling thermal evaporation of a range of materials under vacuum.
- Specified dimensions and electrical ratings: Explicit thickness, width, length, tub geometry, voltage, current, and power values allow precise integration with existing evaporation source holders and power supplies.
Trade-offs
- Limited tub capacity restricts source volume: The 1.2 cc tub capacity constrains the amount of source material that can be loaded per cycle, requiring careful batch planning.
- Requires electrical matching with power supply: Voltage (1.47 V), current (204 A), and power (300 W) must be confirmed compatible with the available resistive-heating power supply before ordering to avoid operational mismatch.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).