The ATOMFAIR® 100kW 232kWh LFP low-temperature liquid-cooled C&I energy storage cabinet is a high-capacity, all-in-one energy storage solution engineered for commercial and industrial applications. With a total energy of 232 kWh, rated voltage of 832 V, rated capacity of 280 Ah, and configuration of 1P260S, this system delivers substantial power for peak shaving, load shifting, and backup power in large-scale commercial facilities, industrial parks, and utility projects. Leveraging advanced Lithium Iron Phosphate (LFP) chemistry, it ensures excellent thermal stability, intrinsic safety, and long service life. The advanced liquid cooling system provides superior thermal management, maintaining optimal battery temperature under high-load operation for enhanced performance and extended cycle life. The IP55 protection rating and wide operating temperature range from -35°C to 60°C guarantee dependable performance in diverse environments. With AC-side output of 400 V and comprehensive safety features, this turnkey solution is ideally suited for C&I energy storage where high capacity, efficiency, and operational safety are paramount.

Technical Specifications

PARAMETER SPECIFICATION
Battery Type Lithium Iron Phosphate (LFP)
Configuration 1P260S
Nominal Voltage 832 V
Nominal Capacity 280 Ah
Total Energy 232 kWh
Total Weight 2.6 ± 0.1 T
Voltage Range 650 ~ 949 V
AC Output Voltage 400 V (-15% ~ 15%)
Rated Charge / Discharge Current 140 A
Cooling Method Liquid Cooling
Ingress Protection IP55
Dimensions (L*W*H) 1400 * 1400 * 2100 mm
Operating Temperature Range -35°C ~ 60°C

Key Features & Advantages

  • Wide Operating Temperature Range: Performs reliably from -35°C to 60°C, ensuring stable operation in diverse climate conditions.

  • High Energy Capacity: Delivers 232 kWh total energy with 100 kW output power and 280 Ah capacity, providing substantial storage for large-scale commercial and industrial applications.

  • High Voltage System: Features 832 V rated voltage with voltage range of 650~949 V, enabling efficient power transmission and reduced system losses.

  • Robust Protection: IP55 rated for protection against dust and water jets, ensuring durability in demanding industrial environments.

  • LFP Chemistry: Employs Lithium Iron Phosphate battery technology with exceptional thermal stability, intrinsic safety, and long service life, delivering reliable performance and lower total cost of ownership.

APPLICATION SCOPE: Commercial and industrial energy storage, peak shaving and valley filling, load shifting, demand charge management, backup power for manufacturing plants, data centers, shopping malls, office complexes, and utility-scale distributed energy storage projects.
PACKAGING: Securely packaged in robust industrial crates with protective internal cushioning and insulation layers to ensure safe transport and handling.
IMPORTANT NOTICE: For optimal performance and safety, operate within -35°C ~ 60°C. Ensure proper liquid cooling system operation with recommended coolant specifications. Use only compatible LFP charging equipment. Do not disassemble or short-circuit. In case of abnormality, disconnect immediately and contact qualified personnel. Dispose according to local regulations. Regular inspection of cooling system and electrical connections is recommended.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet must be operated within an ambient temperature range of -35°C to 60°C and requires a properly functioning liquid cooling system with manufacturer-recommended coolant. Electrical connections must use compatible LFP charging equipment, and the unit must be regularly inspected for cooling system integrity and electrical connection tightness.

  • Temperature Constraint: Operate the cabinet only within the specified ambient temperature range of -35°C to 60°C to prevent thermal runaway or performance degradation.
  • Coolant Requirement: Ensure the liquid cooling system is filled with the recommended coolant and free of leaks to maintain proper thermal management.
  • Electrical Compatibility: Connect only compatible LFP charging equipment to the cabinet to avoid electrical hazards and system damage.
  • Inspection Protocol: Regularly inspect the cooling system and electrical connections for signs of wear, leakage, or loose contacts.
  • Disposal Requirement: Dispose of the cabinet according to local regulations for large-format lithium-ion battery systems.

This procedure covers the initial inspection, coolant verification, electrical connection, and system startup for the cabinet. Follow these steps precisely to ensure safe operation and compliance with manufacturer guidelines.

Required Equipment: Compatible LFP charging equipment, Recommended coolant, Multimeter for voltage verification, Safety gloves and insulated tools

  1. Inspect Cabinet
    Inspect the cabinet exterior for any visible damage, dents, or leaks before moving it to the installation site.
  2. Verify Coolant System
    Verify that the liquid cooling system is filled with the recommended coolant and that all hoses and connections are secure and leak-free.
  3. Position and Level Cabinet
    Position the cabinet on a level, vibration-free surface capable of supporting its 2.6-ton weight and ensure adequate clearance for ventilation.
  4. Connect AC Output
    Connect the AC output terminals to a 400 V electrical system using appropriately rated cables and connectors, ensuring correct phase orientation.
  5. Set Operating Parameters
    Set the operating voltage range to between 650 V and 949 V and configure the charge/discharge current limits to a maximum of 140 A.
  6. Verify Ambient Temperature
    Confirm that the ambient temperature is within the -35°C to 60°C range before energizing the system.
  7. Energize and Monitor
    Energize the system and monitor the initial startup for any abnormal alarms, temperature spikes, or coolant flow irregularities.

How does the liquid cooling system maintain battery performance at the upper and lower extremes of the -35°C to 60°C operating range?

The advanced liquid cooling system actively regulates battery temperature to sustain optimal electrochemical performance across the full -35°C to 60°C range. At low temperatures, the coolant circuit preheats the LFP cells to prevent lithium plating and capacity fade, while at high temperatures it efficiently dissipates heat from the 100 kW discharge load, keeping cells within safe thermal limits. This thermal management is critical for maintaining the rated 280 Ah capacity and 232 kWh total energy delivery under sustained high-load commercial and industrial operation.

Can this 832 V nominal system be directly integrated with existing 400 V AC commercial building infrastructure without an external transformer?

Yes, the cabinet includes an integrated AC-side output of 400 V (-15% to 15%), enabling direct connection to standard 400 V three-phase commercial and industrial distribution panels without requiring an external step-down transformer. The battery-side voltage range of 650–949 V is managed internally by the system's power conversion stage to produce the regulated 400 V AC output. This simplifies installation in facilities such as manufacturing plants, data centers, and office complexes where 400 V service is already available.

What are the specific coolant specifications and maintenance intervals required to prevent thermal runaway in this IP55-rated LFP cabinet?

The manufacturer recommends using only compatible LFP-grade coolant as specified in the product documentation, with regular inspection of the cooling system and electrical connections to ensure safe operation. The IP55 enclosure protects against dust ingress and low-pressure water jets, but the liquid cooling loop must be maintained free of leaks and blockages to prevent localized overheating that could compromise the intrinsic thermal stability of the LFP chemistry. Detailed coolant type and change intervals should be obtained from the ATOMFAIR engineering team for site-specific conditions.

The ATOMFAIR 100kW 232kWh LFP liquid-cooled storage cabinet delivers reliable high-capacity energy storage with a wide -35°C to 60°C operating range, but its 2.6-ton weight and mandatory liquid cooling maintenance impose installation and upkeep requirements.

Positive

  • Wide Temperature Operation: Certified for -35°C to 60°C, this system enables stable C&I operation in extreme climates without additional thermal conditioning, reducing auxiliary power draw.
  • LFP Safety and Cycle Life: Lithium Iron Phosphate chemistry provides intrinsic thermal stability and long service life, lowering total cost of ownership and fire risk in commercial and industrial deployments.

Trade-offs

  • Heavy Installation Logistics: At 2.6 ± 0.1 tons, the cabinet requires specialized lifting equipment and reinforced flooring, increasing site preparation complexity and cost.
  • Liquid Cooling Maintenance: The system demands periodic coolant inspection and replacement per manufacturer specifications; failure to maintain coolant quality degrades thermal performance and battery life.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).

Related products