HC110-Pro Heating Cooling Dry Bath ±0.5°C ATOMFAIR®

$830.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

HC110-Pro heating cooling dry bath with RT-25 to 110 °C range, ±0.5 °C accuracy, 180 W power, TFT display and 99 h 59 min timer. Order now.

Description

HC110-Pro Heating Cooling Dry Bath

Product Type: Temperature control instrument
Research-grade temperature control platform

Product Overview

HC110-Pro Heating Cooling Dry Bath is a research-grade dry bath for controlled block-based heating and incubation of tubes, vials, plates or compatible sample modules in molecular biology, biochemistry, clinical research, quality-control and teaching laboratories. The listed configuration provides temperature control range of Room temperature -25 to 110 °C, temperature control accuracy of ±0.5 °C.

It is suitable for enzyme reactions, sample warming, reagent preparation, nucleic-acid workflow support, protein handling and routine temperature-controlled sample preparation. Select the model according to timer setting (0 min to 99 h 59 min), installation footprint (200 x 235 x 120 mm), block or module format, sample vessel size, power supply, operating environment.

Key Features and Advantages

  • Dry-block temperature control supports repeatable incubation, warming and sample preparation workflows.
  • Temperature range: Room temperature -25 to 110 °C.
  • Temperature control accuracy: ±0.5 °C.
  • Timer range: 0 min to 99 h 59 min.
  • Display: TFT.
  • Confirm compatible heating blocks, modules or sample vessels before ordering.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-TC-HC110-PRO
Function Heating and cooling
Temperature control range Room temperature -25 to 110 °C
Temperature setting range -5 to 110 °C
Temperature control accuracy ±0.5 °C
Display accuracy ±0.5 °C
Power 180 W
Timer 0 min to 99 h 59 min
Maximum heating rate 5.5 °C/min
Maximum cooling rate 2.5 °C/min from 100 °C to room temperature; 0.5 °C/min from room temperature to below room temperature
Display TFT
Custom program capacity 9 programs
Process execution 150
Power supply 110/220 V, 50/60 Hz
Dimensions 200 x 235 x 120 mm
Weight 7.3 kg
Ambient temperature 10 to 40 °C
Relative humidity <80%
Configuration Guidance: Confirm temperature range, block or module compatibility, sample vessel format, power supply and installation environment before ordering.
Technical Support: For method-specific incubation, heating, cooling or module matching requirements, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Ambient temperature must be maintained between 10 and 40 °C with relative humidity below 80% to ensure stable operation. The instrument requires a 110/220 V, 50/60 Hz power supply and must be placed on a level surface with adequate ventilation for heat dissipation.

  • Temperature Range Limitation: The temperature control range is limited to room temperature minus 25 °C down to 110 °C, with a setting range from -5 to 110 °C, requiring ambient conditions to achieve sub-ambient setpoints.
  • Cooling Rate Dependency: Maximum cooling rate decreases from 2.5 °C/min above room temperature to 0.5 °C/min when cooling below room temperature, imposing longer equilibration times for low-temperature protocols.
  • Block Compatibility Requirement: Only compatible heating blocks, modules, or sample vessels specifically designed for the HC110-Pro format must be used to ensure proper thermal contact and avoid instrument damage.

This procedure covers initial setup, program configuration, and safe operation of the dry bath for controlled heating and cooling applications. Follow these steps to ensure accurate temperature control and prevent thermal shock to samples or the instrument.

Required Equipment: Compatible heating block or sample module, Sample tubes, vials, or plates

  1. Install compatible block
    Insert the appropriate heating block or sample module into the dry bath well, ensuring it is fully seated and aligned with the thermal interface.
  2. Power on and set temperature
    Connect the instrument to a grounded 110/220 V power supply, turn on the main switch, and use the TFT interface to set the desired target temperature within the -5 to 110 °C range.
  3. Configure timer or program
    Set the timer from 0 min to 99 h 59 min or load one of the 9 custom programs via the TFT menu to define incubation duration and temperature ramps.
  4. Load samples and start run
    Place prepared sample tubes or plates into the block wells, close any lid if present, and press start to initiate the heating or cooling cycle.
  5. Monitor and retrieve samples
    Observe the TFT display for real-time temperature and remaining time, then remove samples promptly after the cycle completes to avoid unintended thermal drift.

Why is the cooling rate from room temperature to sub-ambient ten times slower than from 100°C to room temperature on the HC110-Pro dry bath, and how does this affect experimental throughput for applications requiring rapid cooling below ambient?

The maximum cooling rate from 100°C to room temperature is 2.5°C/min, whereas from room temperature to below room temperature it is only 0.5°C/min. This difference means that achieving a target temperature well below ambient can take significantly longer. For workflows such as rapid thermal cycling or enzyme quench steps that demand fast sub-ambient cooling, the slower rate in that regime may limit throughput and should be factored into protocol timing.

Does the HC110-Pro come with a heating/cooling block, or is it required to purchase a separate block compatible with specific tube or plate formats, and how do I identify which Atomfair modular block fits the HC110-Pro?

The HC110-Pro is sold as a base temperature control unit without a block or sample module included. The product description explicitly states to confirm compatible heating blocks, modules, or sample vessels before ordering. For block matching—whether for tubes, vials, plates, or custom formats—contact the Atomfair technical sales team at inquiry@atomfair.com, as they can provide the specific modular block options designed to interface with the HC110-Pro's 200 x 235 x 120 mm footprint.

Can the HC110-Pro be operated in a cold room (4°C) or in a high-humidity environment above 80% RH, and what are the risks if operated outside the specified ambient conditions?

The specified ambient operating range is 10 to 40°C with relative humidity below 80%. Running the unit at 4°C (a typical cold room temperature) or above 80% RH exceeds these limits. Operating outside the specified range risks internal condensation, inaccurate temperature control (since the unit relies on ambient air for heat exchange), potential electronic damage, and voided warranty. If cold-room use is required, consult Atomfair for guidance on derating or protective measures.

The HC110-Pro Heating Cooling Dry Bath provides precise block-based temperature control from RT-25 to 110°C with ±0.5°C accuracy and programmable timers, suitable for enzyme reactions and nucleic acid workflows. However, its cooling performance below ambient is limited to 0.5°C/min and requires a controlled lab environment.

Positive

  • Wide temperature range with active cooling: Covers RT-25 to 110°C, enabling both heating and controlled cooling below ambient for enzyme reactions, nucleic acid workflows, and protein handling.
  • Programmable multi-step protocols: Supports 9 custom programs and 150 process executions, allowing automated, repeatable incubation sequences without manual intervention.

Trade-offs

  • Slow cooling rate below ambient: Maximum cooling rate from room temperature to below room temperature is only 0.5°C/min, limiting rapid temperature transitions for time-sensitive protocols.
  • Ambient temperature and humidity constraints: Requires a controlled environment of 10–40°C and <80% relative humidity to maintain specified performance and equipment reliability.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).