TopPette 12-channel 50-300 µL Pipette

Product Type: Manual pipette
Research-grade liquid handling platform

Product Overview

TopPette 12-channel 50-300 µL Pipette is a fully autoclavable manual pipette for accurate microliter liquid handling in research, quality-control and teaching laboratories. The 50-300 µL range supports microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer where repeatability, stable tip fit and traceable calibration data are important.

Select this model according to its 12-channel format, 50-300 µL working range, 5 µL increment, compatible tips and sterilization requirements. The technical specifications list the order model, product family, test volumes, systematic error, random error and calibration reference for procurement, method setup and routine performance review.

Key Features and Advantages

  • 12-channel configuration for microplate loading, PCR plate preparation, ELISA workflows and repeated parallel reagent transfer.
  • Volume range 50-300 µL with 5 µL increment.
  • Sterilization suitability: Lower half autoclavable where indicated.
  • Systematic error and random error values are listed by test volume for calibration review.
  • Suitable for routine liquid transfer, assay setup, sample preparation and laboratory training workflows.

Technical Specifications

Parameter Specification / Available Values
Atomfair Model AF-LH-TOPPETTE-12CHANNEL-50-300-µL
Product Family TopPette
Channel count 12-channel
Volume range 50-300 µL
Increment 5 µL
Test volume(s) 300 / 150 / 50 µL
Systematic error Systematic error retained by test volume in the technical table.
Random error Random error retained by test volume in the technical table.
Sterilization suitability Lower half autoclavable where indicated
Calibration reference ISO 8655-2 user calibration reference indicated in the technical table
Technical table note Multichannel adjustable technical table
Configuration Support: Confirm compatible tips, calibration requirements, sterilization needs and laboratory workflow before ordering.
Technical Support: For method-specific volume matching, calibration planning, accessory compatibility or bulk laboratory configuration, contact the Atomfair technical sales team.
TAILORED SOLUTIONS FOR RESEARCH
For bulk orders, OEM requirements, accessory matching, platform selection or configuration confirmation, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
Supplier: Atomfair
Brand: ATOMFAIR®

Only the lower half of the pipette is autoclavable; full sterilization requires disassembly and may void warranty if the upper assembly is exposed to heat. Calibration must follow ISO 8655-2 using the three specified test volumes to maintain systematic and random error specifications.

  • Autoclaving Limitation: Only the lower half of the pipette is autoclavable at 121°C for 20 minutes; the upper assembly must not be autoclaved to avoid damage.
  • Calibration Requirement: Calibration to ISO 8655-2 is required at the three test volumes (300, 150, 50 µL) to ensure accuracy and precision within listed systematic and random error limits.
  • Tip Compatibility: Use only compatible tips designed for 50-300 µL multichannel pipettes to ensure proper seal and accurate volume delivery.
  • Volume Range Constraint: Do not operate outside the 50-300 µL range; the 5 µL increment must be strictly adhered to for reproducible results.
  • Prevention of Cross-Contamination: When handling biohazardous or corrosive liquids, clean and sterilize the pipette according to manufacturer instructions to prevent carryover.

This procedure covers volume setting, tip attachment, calibration verification, and sterilization of the lower half for routine laboratory use. Adherence to volume range and calibration schedule ensures consistent performance across microplate and PCR workflows.

Required Equipment: TopPette 12-channel pipette, Compatible 50-300 µL pipette tips, Calibration reference tool (per ISO 8655-2), Autoclave capable of 121°C

  1. Set the volume
    Rotate the volume adjustment knob to dial in the desired volume within the 50-300 µL range in 5 µL increments.
  2. Attach tips
    Press the pipette firmly onto a rack of compatible 50-300 µL tips until a secure seal is achieved.
  3. Perform calibration check
    Aspirate and dispense the test volumes (300, 150, 50 µL) using a calibrated balance and compare readings against ISO 8655-2 systematic and random error limits.
  4. Autoclave lower half if needed
    Disassemble the lower half of the pipette and sterilize in an autoclave at 121°C for 20 minutes, ensuring the upper assembly is not exposed.
  5. Perform liquid transfer
    Aspirate by depressing the plunger to the first stop, immersing the tips, then slowly releasing; dispense by depressing to the second stop.

How do the systematic and random errors of the TopPette 12-channel 50-300 µL pipette compare across the three test volumes of 300, 150, and 50 µL?

The technical specifications list systematic and random error values for each test volume (300, 150, and 50 µL) in the integrated technical table, as retained from ISO 8655-2 calibration reference. Specific numerical error figures are not provided in the product overview; therefore, exact comparisons require consultation of the full technical table or manufacturer data. The pipette uses a 5 µL increment across the entire 50–300 µL range, and precision typically varies with volume, but quantitative values are available from Atomfair upon request.

What pipette tips are compatible with the TopPette 12-channel 50-300 µL pipette and are tips included with the unit?

The product description advises users to confirm compatible tips before ordering, but does not specify exact tip models or brands. The pipette is intended for microplate loading, PCR plate preparation, ELISA workflows, and parallel reagent transfer, which typically require standard 300 µL or 200 µL multichannel tips. Tips are not included with the pipette; they must be sourced separately based on the laboratory's preferred tip dimensions and quality standards.

What does it mean that the lower half of the TopPette pipette is autoclavable, and what sterilization conditions are recommended?

The specification states 'lower half autoclavable where indicated,' meaning only the tip cone assembly can be autoclaved, not the upper handle or volume adjustment mechanism. Specific autoclave temperature, pressure, or cycle parameters are not provided in the description. Users should follow standard laboratory autoclaving protocols for polypropylene components and contact Atomfair technical support for detailed sterilization guidelines to avoid damage to non-autoclavable parts.

The TopPette 12-channel 50-300 µL pipette offers a 12-channel format for parallel liquid handling in microplate and PCR workflows, with a 50-300 µL range and 5 µL increment. Its lower half is autoclavable for sterilization, but users must independently verify compatible tips and calibration data per the technical table.

Positive

  • 12-channel parallel liquid handling: Enables simultaneous microplate loading, PCR plate preparation, and ELISA workflows, improving throughput for repeated reagent transfer and assay setup.
  • Lower half autoclavable: The lower portion can be sterilized via autoclave, reducing cross-contamination risk in routine laboratory use without requiring full disassembly.

Trade-offs

  • Partial autoclavability only: Only the lower half is autoclavable; the upper assembly is not, limiting full sterilization capability and requiring careful handling of heat-sensitive components.
  • Requires independent tip and calibration verification: Compatible tips, calibration requirements, and sterilization needs must be confirmed by the user before ordering, as the product description does not provide complete validation data.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).