Atomfair AED 738 Automatic Extraction Device >95% Recovery 7min Fast Extraction 10-500ml Water Sample Volume

The Atomfair AED 738 Automatic Extraction Device offers >95% recovery, 7min fast oil-in-water extraction, 10-500ml adjustable sample volume, closed pipeline design, and anti-cross contamination—ideal for lab water pretreatment.

Description





Atomfair AED 738 Automatic Extraction Device

Atomfair AED 738 Automatic Extraction Device

Product Overview

Atomfair AED 738 Automatic Extraction Device is designed in accordance with international standards, a special equipment for water sample pretreatment, mainly suitable for oil-in-water extraction scenarios, providing efficient pretreatment support for infrared photometric oil analyzers and other testing instruments. Based on single-chip microcomputer control technology, equipped with precision peristaltic pump and high-power air pump, the equipment realizes full mixing of water sample and extractant with high extraction efficiency and stable effect. The processed samples can be directly tested on the machine, widely used in environmental monitoring, water quality testing and other laboratory scenarios.

Core Product Features

  1. Fully automatic whole process without manual intervention: Automatically complete all steps of water sample liquid adding, extraction, dehydration and sample output. No additional demulsification treatment is needed for water samples with general emulsification degree, greatly simplifying the operation process and improving processing efficiency.
  2. Closed design, safe and environmental friendly: The whole process adopts closed pipeline operation to eliminate the volatilization of harmful gases, minimize the harm to the health of operators and environmental pollution, complying with international safety and environmental protection standards.
  3. Multi anti-pollution design with accurate data: Equipped with independent pipeline cleaning function to avoid cross pollution between water samples of high and low concentrations; added blank extraction function to strictly control measurement error, ensure the consistency of blank and sample background, and guarantee the accuracy of test data.
  4. High efficiency and fast speed, suitable for diverse needs: Single extraction only takes 7 minutes, the processing efficiency is far higher than traditional manual operation; supports wide range water sample volume adjustment of 10-500ml, matched with fixed extractant volume of 50ml, suitable for sample processing needs of different testing scenarios.

Technical Parameters

Technical Index Specific Parameter
Working mode Air-blowing fully automatic extraction
Applicable scenario Oil-in-water extraction (Pretreatment for infrared photometric oil analyzer)
Water sample volume 10-500ml
Extractant volume 50ml
Extraction time 7min
Recovery rate >95%
Input power 50W
Power supply specification 220V 50Hz
Net weight 18KG
Overall dimension 670×510×270mm

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.