Description
1435L-6 Anti-Static Ultra-Low-Humidity (1%-10% RH) Dry CabinetsDry storage cabinet, ultra-low-humidity control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CONTROLLED DRY STORAGE SOLUTIONS
For volume selection, humidity grade confirmation or optional configuration, contact our engineering sales team.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Supplier: Atomfair
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The cabinet requires upright transport and stable level placement to ensure proper door sealing and dehumidification performance. Maintaining closed doors during operation and minimizing ambient exposure are essential to prevent humidity recovery and material degradation.
- Transport Orientation: Transport the cabinet upright with reinforced outer protection to avoid structural damage.
- Level Placement: Place the cabinet on a level surface and adjust feet if necessary to ensure stable placement.
- Door Seal Integrity: Confirm the magnetic door gasket seals properly and the door is not warped.
- Stable Power Connection: Connect to a stable power source and verify the LCD display shows current humidity and temperature.
- Door Discipline: Keep the cabinet door closed except during brief access to prevent humidity spikes.
Follow these steps to safely install the cabinet and begin ultra-low-humidity storage of moisture-sensitive materials. Proper positioning, power connection, and humidity stabilization are critical before introducing stored items.
Required Equipment: Lifting equipment or dolly, Spirit level
- Transport cabinet
Transport the cabinet upright using suitable lifting equipment to avoid impact. - Level installation surface
Position the cabinet on a level surface and verify with a spirit level. - Prepare door and shelves
Confirm door sealing and adjust shelves as needed for stored items. - Connect power
Connect the power cord and observe the LCD display for normal operation. - Set humidity set point
Set the desired humidity set point using the control panel. - Stabilize humidity
Allow the cabinet to dehumidify and stabilize at the set point. - Load materials
Load moisture-sensitive materials and keep the door closed during storage.
How does the ultra-low-humidity (1%-10% RH) DC-Series cabinet compare to the extreme-low-humidity (1%-3% RH) model for long-term storage of MSD components, and what factors determine the appropriate humidity grade?
The ultra-low-humidity model (1%-10% RH) is suitable for most moisture-sensitive devices (MSDs) and IC packages, while the extreme-low-humidity model (1%-3% RH) provides even lower humidity for highly sensitive components with lower MSL ratings. The choice depends on the specific moisture sensitivity level of the components and the required storage conditions per industry standards. The cabinet uses the same Honeywell sensor (±3% RH accuracy) and automatic dehumidification system across both grades, so the primary difference is the set point range and dehumidification target.
Can the 1435L-6 anti-static dry cabinet be used to store optical components with delicate coatings, and what features mitigate the risk of moisture-induced damage or condensation during transfer?
Yes, the cabinet is designed for optical devices and polymers. The automatic electronic dehumidification maintains 1%-10% RH without desiccant consumables, and the Honeywell sensor provides ±3% RH accuracy with low drift. To mitigate condensation risk during transfer, the cabinet offers optional nitrogen purge for inert-atmosphere management and a gradual dehumidification profile. The important notice advises validating the storage process before formal use and considering nitrogen purge or alarm options when process risk is high.
What are the floor space requirements and power considerations for installing the 1435L-6 dry cabinet in a standard laboratory environment?
The cabinet has outer dimensions of 1200 x 700 x 1860 mm, requiring approximately 0.84 m² of floor space and a minimum ceiling height of 1860 mm. Power specifications are not provided in the source, but the microcomputer control features set-point memory after power interruption, ensuring recovery. The anti-static powder-coated steel body and magnetic sealing gasket are suitable for laboratory use. For precise power requirements, contact the Atomfair engineering team.
The Atomfair 1435L-6 anti-static ultra-low-humidity dry cabinet (model AF-DC1435CF-6) delivers 1%-10% RH control with a Honeywell sensor and automatic electronic dehumidification, but requires reinforced transport, level installation, and validation for high-risk processes.
Positive
- Ultra-low humidity range 1%-10% RH: Suitable for moisture-sensitive devices such as MSDs, IC packages, optical components, and polymers that degrade rapidly above 10% RH.
- Honeywell sensor with low annual drift: ±3% RH accuracy and 0.3% annual drift ensure reliable long-term humidity monitoring without frequent recalibration.
Trade-offs
- Requires careful handling and leveling: The 1435L cabinet must be transported upright with reinforced protection and leveled after installation to maintain door seal integrity and stable operation.
- Validation needed for ultra-low humidity use: For 1%-10% RH applications, the manufacturer recommends validating storage conditions before formal use and considering nitrogen purge or over-humidity alarm options for high-risk processes.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).