LFP C&I energy storage cabinet with 100kW output, 215kWh capacity, 768V nominal voltage, IP55 rating, and -35°C to 60°C operation. Order now.

Description

100kW 215kWh LFP Low-Temperature Air-Cooled C&I Energy Storage Cabinet | ATOMFAIR

COMMERCIAL GRADE PRODUCTION

Product Overview

The ATOMFAIR® 100kW 215kWh LFP low-temperature air-cooled C&I energy storage cabinet is a robust and cost-effective energy storage solution engineered for commercial and industrial applications. With a total energy of 215 kWh, rated voltage of 768 V, rated capacity of 280 Ah, and configuration of 1P240S, this system delivers substantial power for peak shaving, load shifting, and backup power in large-scale commercial facilities, industrial parks, and utility projects. Leveraging advanced Lithium Iron Phosphate (LFP) chemistry, it ensures excellent thermal stability, intrinsic safety, and long service life. The intelligent air cooling system with temperature sensors and safety monitoring automatically regulates airflow to maintain optimal battery temperatures, ensuring consistent performance and enhanced safety. The IP55 protection rating and wide operating temperature range from -35°C to 60°C guarantee dependable operation in diverse environments. With AC-side output of 400 V and simplified system architecture, this turnkey solution is ideally suited for C&I energy storage where reliability, cost-effectiveness, and ease of maintenance are critical.

Technical Specifications

PARAMETER SPECIFICATION
Battery Type Lithium Iron Phosphate (LFP)
Configuration 1P240S
Nominal Voltage 768 V
Nominal Capacity 280 Ah
Total Energy 215 kWh
Total Weight 2.7 ± 0.1 T
Voltage Range 600 ~ 876 V
AC Output Voltage 400 V (-15% ~ 15%)
Rated Charge / Discharge Current 140 A
Cooling Method Air Cooling
Ingress Protection IP55
Dimensions (L*W*H) 1500 * 1121 * 2200 mm
Operating Temperature Range -35°C ~ 60°C

Key Features & Advantages

  • Wide Operating Temperature Range: Performs reliably from -35°C to 60°C, ensuring stable operation in diverse climate conditions.

  • High Energy Capacity: Delivers 215 kWh total energy with 100 kW output power and 280 Ah capacity, providing substantial storage for large-scale commercial and industrial applications.

  • High Voltage System: Features 768 V rated voltage with voltage range of 600~876 V, enabling efficient power transmission and reduced system losses.

  • Robust Protection: IP55 rated for protection against dust and water jets, ensuring durability in demanding industrial environments.

  • LFP Chemistry: Employs Lithium Iron Phosphate battery technology with exceptional thermal stability, intrinsic safety, and long service life, delivering reliable performance and lower total cost of ownership.

APPLICATION SCOPE: Commercial and industrial energy storage, peak shaving and valley filling, load shifting, demand charge management, backup power for manufacturing plants, data centers, shopping malls, office complexes, and distributed energy storage projects.
PACKAGING: Securely packaged in robust industrial crates with protective internal cushioning and insulation layers to ensure safe transport and handling.
IMPORTANT NOTICE: For optimal performance and safety, operate within -35°C ~ 60°C. Ensure proper liquid cooling system operation with recommended coolant specifications. Use only compatible LFP charging equipment. Do not disassemble or short-circuit. In case of abnormality, disconnect immediately and contact qualified personnel. Dispose according to local regulations. Regular inspection of cooling system and electrical connections is recommended.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This cabinet requires strict adherence to environmental and safety constraints to prevent electrical hazards and thermal runaway. Operation outside the specified temperature range or with improper cooling can lead to accelerated degradation or catastrophic failure.

  • Temperature Range: Operate the cabinet only within the ambient temperature range of -35°C to 60°C to maintain battery stability and performance.
  • Cooling System: Ensure the air-cooling system is functioning correctly and free from obstructions to prevent overheating.
  • Electrical Safety: Do not disassemble or short-circuit the cabinet, as high voltage and stored energy pose severe shock and fire risks.
  • Disposal: Dispose of the cabinet at end-of-life according to local regulations for lithium-ion battery waste.

Follow these steps to safely deploy and operate the energy storage cabinet. Regular inspection and adherence to compatible equipment are essential for safe operation.

  1. Verify Ambient Temperature
    Verify that the ambient temperature is within the specified operating range of -35°C to +60°C before system activation.
  2. Inspect Cooling System
    Inspect the air-cooling system to ensure proper airflow and absence of obstructions.
  3. Connect Compatible Charging Equipment
    Connect the cabinet to a compatible LFP charging system that meets the rated voltage and current specifications.
  4. Visual Inspection of Electrical Connections
    Perform a visual inspection of electrical connections for signs of wear or corrosion before each operational cycle.
  5. Respond to Abnormalities
    Disconnect the system from power and contact qualified personnel immediately if any abnormality occurs.

How does the 100kW 215kWh LFP cabinet maintain thermal stability during high-rate discharge in sub-zero ambient conditions?

The cabinet uses an intelligent air cooling system with temperature sensors and safety monitoring that automatically regulates airflow to maintain optimal battery temperatures, even at the low end of its -35°C to 60°C operating range. The LFP chemistry provides intrinsic thermal stability, and the system is rated for reliable operation down to -35°C without requiring a separate liquid cooling loop, simplifying infrastructure demands in cold climates.

Can this 768 V cabinet be directly integrated into a 400 V AC commercial facility without a step-down transformer?

Yes, the system provides AC-side output at 400 V (-15% to 15%), matching the standard 400 V three-phase distribution voltage used in many commercial and industrial facilities. This eliminates the need for an external step-down transformer, reducing system complexity and installation cost. The voltage range of 600–876 V DC supports efficient power conversion to the required 400 V AC output.

What are the handling and installation requirements for the 2.7-ton cabinet given its IP55 rating and dimensions?

The cabinet weighs 2.7 ± 0.1 T and measures 1500 x 1121 x 2200 mm, requiring industrial-grade lifting equipment and a reinforced floor for installation. The IP55 rating allows outdoor or dusty indoor placement, but the air cooling intake and exhaust must remain unobstructed. The unit ships in a robust industrial crate with internal cushioning; on-site positioning should account for front-access service clearance and compliance with local electrical codes for 768 V DC systems.

This 100kW/215kWh air-cooled LFP cabinet delivers reliable peak shaving and backup power for commercial and industrial sites, with LFP safety advantages and a wide -35°C to 60°C operating range, though its 2.7-ton weight and need for dedicated charging equipment impose site-specific constraints.

Positive

  • Wide operating temperature range: Operates from -35°C to 60°C, enabling deployment in extreme climates without performance degradation.
  • Intrinsically safe LFP chemistry: Lithium Iron Phosphate provides excellent thermal stability, intrinsic safety, and long cycle life, reducing fire risk and total cost of ownership.

Trade-offs

  • High system weight: Total weight of 2.7 ± 0.1 tons requires reinforced flooring and specialized handling equipment for installation.
  • Requires compatible charging infrastructure: Must use only compatible LFP charging equipment and perform regular inspection of cooling system and electrical connections, adding operational overhead.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).