Description
60V Motive Battery Pack Series (17S1P Pouch Cell Grade) | ATOMFAIRCOMMERCIAL GRADE · PRODUCTION
|
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||
This battery pack operates within a restricted thermal discharge window of -30°C to +55°C depending on variant and requires systematic BMS balancing to prevent premature capacity fade. The IPX7-rated enclosure permits temporary immersion but terminal contacts must never be bridged beyond rated load limits.
- Thermal Operating Limits: Prolonged exposure to temperatures outside the specified discharge range may accelerate cell degradation or trigger protective shutdown.
- BMS Balancing Requirement: Failure to execute intelligent balancing cycles during charging can cause layer degradation and reduced cycle life.
- Terminal Contact Safety: Prevent any conductive bridging between terminals beyond the design load to avoid short-circuit and thermal runaway.
- Swapping Alignment Protocol: Ensure structural lock alignment tolerances match the cabinet footprint before locking handles to prevent mechanical damage.
- Charging Authorization: Only use chargers and parameters authorized by the manufacturer to maintain safe operation and warranty compliance.
Initialize the pack by inspecting the enclosure and verifying BMS telemetry before insertion into a swapping cabinet or vehicle. Subsequent steps ensure proper alignment, locking, and authorized charging to avoid electrical or mechanical hazards.
Required Equipment: Insulated gloves, Multi-meter with CAN interface, Swapping cabinet alignment fixture, Authorized charger
- Inspect Enclosure
Inspect the enclosure for cracks, deformation, or moisture ingress before handling. - Verify BMS Communication
Verify BMS communication by checking SOC and SOH via the telemetry interface. - Align Pack with Cabinet
Align the pack's locking tabs with the cabinet's guide rails until they engage smoothly. - Lock Structural Handles
Lock the structural handles fully to secure the pack in the compartment. - Connect Power Terminals
Connect the main power terminals only after verifying cabinet circuit isolation. - Initiate Charging
Initiate charging using only manufacturer-specified parameters and monitoring equipment. - Monitor Temperature
Monitor battery temperature continuously during the initial charge cycle for anomalies.
What is the performance trade-off between low-temperature tolerance and cumulative energy capacity in the 60V motive battery pack series?
The 17S1P pack lineup offers two capacity streams with a clear trade-off: the 35Ah (2100 Wh) variant supports continuous discharge down to -30°C, while the higher-capacity 50Ah (3000 Wh) variant is limited to -20°C. Both variants share a 3.0C continuous discharge rate and over 2500 deep discharge cycles to 70% capacity, so the choice depends on whether extreme cold operation or maximum energy density is prioritized.
Can the 60V motive battery pack be integrated directly into existing smart battery swapping cabinet infrastructure?
Yes, the pack is engineered specifically for smart battery swapping networks with an IPX7 hermetic seal, native multi-protocol telemetry (Bluetooth, RS485, CAN), and a BMS providing SOC/SOH data for cloud backend integration. However, physical dimensions differ between variants: the 35Ah pack measures 200×175×310 mm and the 50Ah pack 192×175×340 mm, so cabinet lock alignment tolerances must be verified before structural handles are secured.
What safety and handling precautions are required for the 60V lithium-ion battery pack during swapping and charging operations?
The pack requires systematic intelligent battery management balancing to block premature layer degradation loops. Terminal contacts must not be linked past designated load limits, and charging must be executed exclusively under authorized safety parameters. The IPX7 environmental protection rating allows safe operation under flood immersion and heavy downpours, but swapping lock alignment tolerances must be properly lined up before locking structural handles into automated cabinet footprints.
This 60V 17S1P motive battery pack series offers two capacity variants (2100 Wh and 3000 Wh) with IPX7 sealing and 2500-cycle durability, but the 50Ah variant has reduced cold tolerance (-20°C vs -30°C) and both require systematic BMS balancing for longevity.
Positive
- Enhanced cycle durability: Rated for over 2500 deep discharge cycles to ≥70% capacity limits, significantly reducing long-term total cost of ownership for large urban fleets.
- IPX7 environmental sealing: Industrial-grade hermetic shell sealing provides protection against flood immersion, heavy downpours, and high-humidity swap cabinet environments.
Trade-offs
- Capacity-dependent cold performance: The 50Ah variant operates only down to -20°C, while the 35Ah variant extends to -30°C, limiting cold-climate deployment of the higher-capacity option.
- BMS balancing overhead: Systematic intelligent battery management balancing is required to prevent premature layer degradation, adding infrastructure and maintenance complexity for fleet operators.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).