The 8540140-15 is a specialized high-energy-density primary (non-rechargeable) lithium power cell engineered for mission-critical applications in extreme environments. Delivering a massive 15Ah capacity, this cell features a unique electrolyte chemistry that allows for efficient discharge down to -40C. It is designed for one-time high-reliability power delivery where consistent output and extreme environmental resilience are non-negotiable. For bulk inquiries or official volume quotations, please contact us via email at inquiry@atomfair.com.
Technical Specifications
| Parameter Item | Technical Specification | Conditions / Remarks |
|---|---|---|
| Cell Model | 8540140-15 | Primary Cell (Non-rechargeable) |
| Nominal Capacity | >= 15Ah | 0.5C, 25C, Fresh Cell |
| Nominal Voltage | 3.8V | 0.33C, 25C |
| Work Voltage Range | 2.3V – 4.3V | Range for -40C to 0C |
| Cell Dimensions | 8.5 x 40 x 140 mm | Thickness x Width x Length |
| Cell Weight | 112 +/- 3g | Lightweight Design |
| Max. Cont. Discharge | 3C (45A) | -40C to 25C Range |
| Max. Pulse Discharge | 5C (75A) | 10s @ 50% SOC |
| Internal Resistance | < 3 mOhm | 1kHz @ 70% SOC |
| Operating Temp Range | -40C to 55C | Discharge Capability |
Core Features & Advantages
Sub-Zero Performance
Specifically optimized for ultra-low temperature environments, maintaining over 70% capacity retention even at -40C.
Extreme Discharge Rate
Capable of 3C continuous and 5C pulse discharge (75A), providing heavy-duty power for high-intensity equipment.
Validated Reliability
Passed 1.5m concrete fall tests, low-pressure (vacuum) tests, and external short-circuit protocols with zero fire or explosion risk.
Low Thermal Loss
With internal resistance < 3mOhm, the cell minimizes heat generation during high-power operation, protecting sensitive electronics.
Application Scope
- Polar Research Instrumentation
- High-Altitude Aerospace Prototypes
- Sub-Zero Emergency Power Systems
- Military-Grade Hardware Prototyping
- UAV Deep-Space Exploration Models
- Remote Environmental Monitoring
Accessories & Customization
Safety Warning: This is a PRIMARY (Non-rechargeable) cell. Charging is strictly prohibited and may cause thermal runaway.
Customization Options: Available with custom spot-welded nickel tabs, specialized insulation wrapping, and series/parallel pack assembly for specific voltage requirements. Engineering support is provided for integration into cryo-stabilized battery boxes.
This primary lithium cell must be stored in a cool, dry environment between -40°C and 55°C to prevent thermal degradation. Charging is strictly prohibited as it may cause thermal runaway, fire, or explosion.
- Storage Temperature Range: Maintain storage temperature within -40°C to 55°C to preserve electrochemical stability.
- Charge Prohibition: Never attempt to recharge this non-rechargeable cell, as it may lead to catastrophic thermal runaway.
- Short Circuit Prevention: Avoid external short circuits by insulating terminals and storing cells in non-conductive packaging.
- Mechanical Integrity: Inspect for denting, swelling, or punctures before use to mitigate risk of internal short circuit.
- Disposal Protocol: Discharge fully through a resistive load before disposal per local hazardous waste regulations.
This cell delivers high current and requires controlled deployment to avoid thermal or electrical hazards. Follow these steps to safely integrate the cell into a device or test setup.
Required Equipment: Insulated gloves, Digital multimeter, Non-conductive work surface, Cell holder with fused leads
- Inspect cell condition
Visually examine the cell casing for dents, swelling, or corrosion before handling. - Verify open-circuit voltage
Measure voltage across terminals using a multimeter to confirm it lies within 2.3V to 4.3V. - Mount cell securely
Place the cell into a non-conductive holder or enclosure with fused output leads. - Connect resistive load
Attach a load rated for at least 45A continuous and monitor for excessive heat generation. - Monitor during discharge
Check cell temperature periodically and disconnect immediately if surface exceeds 60°C.
What capacity retention can be expected from the 8540140-15 cell at -40°C compared to room temperature, and what trade-off in voltage range is required?
The 8540140-15 maintains over 70% capacity retention at -40°C. To achieve this extreme low-temperature performance, the operating voltage range shifts to 2.3V–4.3V (versus nominal 3.8V at 25°C). This voltage trade-off is necessary to sustain discharge capability down to -40°C while delivering the full 15Ah capacity.
What are the critical integration constraints for using the 8540140-15 primary cell in a series or parallel pack assembly?
The 8540140-15 is a primary (non-rechargeable) cell, meaning charging is strictly prohibited to avoid thermal runaway. For pack assembly, customization options include spot-welded nickel tabs and specialized insulation wrapping. Engineering support is provided for integration into cryo-stabilized battery boxes to maintain safe operation under extreme conditions.
What safety tests has the 8540140-15 passed, and what handling precautions are required for storage and transport?
The cell passed 1.5m concrete fall tests, low-pressure (vacuum) tests, and external short-circuit protocols with zero fire or explosion risk. Despite its robust safety validation, it is a primary cell and must never be charged. Storage and transport should follow standard lithium primary cell precautions; the operating temperature range is -40°C to 55°C.
The 8540140-15 is a 15Ah primary lithium cell optimized for extreme low-temperature discharge down to -40°C with 70% capacity retention, supporting 3C continuous and 5C pulse discharge. Its non-rechargeable chemistry and 55°C upper temperature limit require careful system integration for dedicated single-use applications.
Positive
- Ultra-low temperature capability: Maintains over 70% capacity retention at -40°C, enabling reliable power for polar, high-altitude, and aerospace instrumentation in sub-zero environments.
- High discharge rate with low internal resistance: Supports 3C continuous (45A) and 5C pulse (75A) discharge while internal resistance remains below 3 mOhm, minimizing thermal loss during heavy-duty operation.
Trade-offs
- Non-rechargeable primary cell: This cell is single-use only; charging is strictly prohibited and may cause thermal runaway. It must be replaced after depletion, increasing long-term operational cost.
- Limited upper operating temperature: Discharge capability is specified only up to 55°C, restricting use in applications that may experience sustained temperatures above this threshold without thermal management.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).