DNP Pure Nickel Battery Anode Tabs 3×0.1mm ATOMFAIR®

$55.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade pure nickel anode tabs (≥99.6% Ni, 3×0.1mm) with DNP black adhesive film, 180° bend ≥7 cycles, no delamination in electrolyte at 85°C. In stock.

Description

ATOMFAIR® RESEARCH-GRADE PURE NICKEL BATTERY ANODE TABS (3 × 0.1 MM)

RESEARCH GRADE MATERIAL

Product Overview

ATOMFAIR® premium research-grade **nickel tabs** are engineered with absolute material integrity for advanced electrochemical laboratories and industrial R&D prototypes. Featuring a default geometry of **3 × 0.1 mm**, these negative terminal connectors utilize high-purity raw materials combined with high-performance DNP adhesive film to ensure exceptional hermetic scaling. Designed explicitly for precise **pouch cell assembly**, each standardized batch mitigates material variance between experimental groups, eliminating baseline disruptions during long-term cycling and rigorous charge-discharge benchmarking while guaranteeing **pure nickel ≥ 99.60%** chemical consistency.

Technical Specifications

PARAMETER DETAILS
Chemical Purity Pure Nickel (Ni) ≥ 99.60%
Default Physical Dimensions 3.0 mm (Width) × 0.1 mm (Thickness)
Polymer Adhesive Interface DNP Black High-Performance Film (Default)
Mechanical Flexibility 180° Reverse Bending Cycles ≥ 7 Times
Corrosion & Bonding Resistance No delamination/corrosion after 4 hours in electrolyte at 85°C
Standard Packing Unit 100 Pieces per Box
Shelf Life & Warranty 12 Months (Under sealed validation)
Alternative Options Explore our related catalog or custom dimensions. For urgent technical custom requests or bulk inquiries, please contact our support team.

Key Features & Advantages

  • Ultra-Low Internal Resistance: Formulated with premium Ni ≥ 99.60% to maximize electrical conductivity and minimize parasitic ohmic drops during high-rate transient tests.
  • Thermal-Chemical Hermetic Shielding: Integrated DNP black adhesive film retains its structural cross-linking during hot-pressing, preventing electrolyte micro-leakage and chemical crosstalk.
  • Fatigue-Resistant Structural Integrity: Tolerates more than 7 multi-directional 180° folds without micro-cracking, securing high operational yields during automated stacking or manual cell folding.
  • Standardized High-Volume Packaging: Delivered in upscaled 100-piece batches to eliminate consumable supply gaps midway through critical electrochemical testing matrixes.

APPLICATION SCOPE: Perfectly optimized for pouch-type lithium-ion battery prototyping, novel electrode characterization workflows, high-C-rate cycling analysis, and compatibility testing for emerging electrolyte architectures within university laboratories and industrial cleanrooms.
PACKAGING: Vacuum-sealed in structured standard boxes containing 100 active components per batch, safeguarded against atmospheric oxygenation and humidity-induced surface passivation.
IMPORTANT NOTICE: Materials must be handled in an inert atmosphere (glovebox environment) or controlled dry room conditions where relative humidity is maintained at ≤ 70% RH. Store strictly within the temperature window of 5°C to 25°C. Do not touch the surface metallic terminal or polymer film without protective ESD/nitrile gloves to avoid chemical lipid contamination.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

These tabs require heat-sealing to form a hermetic bond during pouch cell assembly. The adhesive interface must endure electrolyte exposure and mechanical bending without failure.

  • Heat Seal Requirement: The DNP adhesive film must be heat-sealed under controlled temperature and pressure to achieve a hermetic barrier.
  • Electrolyte Resistance: The bond must resist delamination and corrosion when immersed in battery electrolyte at 85°C for 4 hours.
  • Mechanical Durability: The tab assembly must withstand at least 7 reverse bending cycles of 180 degrees without adhesive or metal failure.
  • Storage Integrity: Tabs must be stored in sealed packaging to preserve adhesive performance over the 12-month shelf life.

How many 180° reverse bending cycles can the 0.1 mm nickel tab endure before fatigue failure?

The ATOMFAIR nickel anode tab tolerates more than 7 multi-directional 180° folds without micro-cracking, ensuring high operational yields during automated stacking or manual cell folding. This mechanical flexibility is validated at the default 0.1 mm thickness and 99.6% purity.

What electrolyte and temperature conditions must the DNP adhesive film withstand without delamination?

The integrated DNP black high-performance film shows no delamination or corrosion after 4 hours of electrolyte exposure at 85°C. This confirms its thermal-chemical hermetic shielding capability, preventing electrolyte micro-leakage and chemical crosstalk during pouch cell assembly.

What storage and handling conditions are required to preserve the nickel tab's surface integrity?

Materials must be stored vacuum-sealed at 5°C to 25°C with relative humidity ≤70% RH. Handling requires an inert atmosphere (glovebox) or controlled dry room, and protective ESD/nitrile gloves must be worn to avoid chemical lipid contamination on the metallic terminal or polymer film.

These research-grade pure nickel anode tabs deliver ultra-low internal resistance via ≥99.60% purity and withstand over seven 180° folds without micro-cracking, but require inert-atmosphere handling, controlled storage (5–25°C, ≤70% RH), and mandatory glove use to prevent contamination.

Positive

  • Ultra-Low Internal Resistance: High-purity nickel (≥99.60%) maximizes electrical conductivity and minimizes parasitic ohmic drops during high-rate transient tests.
  • Fatigue-Resistant Structural Integrity: Tolerates more than 7 multi-directional 180° folds without micro-cracking, ensuring high yields during automated stacking or manual cell folding.

Trade-offs

  • Controlled Atmosphere and Temperature Storage: Must be handled in inert atmosphere (glovebox) or dry room with ≤70% RH, and stored strictly between 5°C and 25°C, adding infrastructure demands.
  • Mandatory Glove Handling to Avoid Contamination: Surface metallic terminal and polymer film must not be touched without ESD/nitrile gloves to prevent chemical lipid contamination, increasing procedural rigor.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).