Description
Electric Assist Bike Semi-Solid Battery Series | ATOMFAIRCOMMERCIAL GRADE · PRODUCTION
|
||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
The ATOMFAIR semi-solid battery series requires strict temperature control during storage and operation to prevent thermal runaway. Use only with a compatible BMS that enforces over-discharge, over-current, and cell balancing protection.
- Thermal Exposure Limits: Never expose the battery to temperatures exceeding 65°C to prevent electrolyte degradation and thermal runaway.
- BMS Compatibility: Always connect the battery to a compatible BMS with over-discharge, over-current, and cell balancing functions.
- Charge Voltage Compliance: Charge the battery strictly within the manufacturer-recommended voltage range as per the datasheet.
- Pre-Conditioning Procedure: Pre-condition a new battery at room temperature before its first full charge-discharge cycle.
- Mechanical Protection: Protect the battery from physical impact, puncture, or compression to avoid internal short circuits.
Follow these steps to safely handle and initialize the ATOMFAIR semi-solid battery for first use. Proper preconditioning and BMS configuration ensure long cycle life and safe operation.
Required Equipment: Compatible battery management system (BMS), Manufacturer-approved charger
- Inspect Battery
Inspect the battery casing for cracks, swelling, or leakage before initial use. - Connect BMS
Connect a compatible BMS that enforces over-discharge, over-current, and cell balancing limits. - Verify Charger
Confirm the charger output voltage aligns with the battery's specified charge voltage range. - Precondition Battery
Allow the battery to equilibrate at room temperature for at least two hours before the first charge. - Initiate First Charge
Initiate the first charge cycle at a current not exceeding 0.5C rate while monitoring temperature. - Condition Cells
After full charge, perform an initial discharge cycle at 0.2C rate to condition the electrolyte. - Store Safely
Store the battery in a cool, dry environment between 0°C and 45°C to preserve cycle life.
How does the capacity selection between 20 Ah and 13 Ah models affect discharge current and physical integration for e-bike applications?
The 20 Ah model (AFEABS4820) supports a max continuous discharge of 20 A, while the 13 Ah model (AFEABS4813) supports 13 A, directly correlating with power delivery for hill-climbing and acceleration. The 20 Ah variant has larger dimensions (510×80×100 mm) versus the 13 Ah variant (230×95×75 mm), requiring more frame space. Both share 48 V nominal voltage, 13S1P configuration, and ≥1200 cycles to 80% SOH, making capacity selection a trade-off between peak current and physical footprint.
What BMS integration requirements and charge/discharge temperature constraints must be met for the ATOMFAIR Rock Solid semi-solid battery?
The battery requires a compatible BMS with over-discharge, over-current, and cell balancing protection. Charge temperature range is strictly 0 to +45°C, while discharge temperature range is -20 to +65°C. The discharge cut-off voltage is 32.5 V, and the 13S1P configuration must be respected. Pre-condition new batteries at room temperature before first full cycle to ensure proper activation.
What safety testing and storage precautions apply to the ATOMFAIR semi-solid electrolyte e-bike battery series?
The semi-solid electrolyte provides enhanced thermal stability, leak-proof construction, and passes nail penetration and overcharge tests for superior safety. Avoid prolonged exposure above 65°C. Packaging includes industrial-grade moisture-proof cartons with foam inserts, individual cell compartments, and anti-static shielding. For storage, pre-condition at room temperature before first cycle and always use a compatible BMS.
The Rock Solid Series semi-solid state battery for e-bikes delivers enhanced thermal stability and leak-proof construction via semi-solid electrolyte, with two capacity variants (20 Ah and 13 Ah) both rated for -20°C to +65°C discharge and ≥1200 cycles to 80% SOH, though charge is restricted to 0–45°C and a compatible BMS is mandatory.
Positive
- Semi-solid electrolyte safety: Enhanced thermal stability and leak-proof construction provide superior safety over conventional liquid cells, with verified nail penetration and overcharge test compliance.
- Wide temperature discharge range: Reliable discharge from -20°C to +65°C enables all-season e-bike operation, while ≥1200 cycles to 80% SOH supports years of daily commuting.
Trade-offs
- Restricted charge temperature window: Charging is only permitted between 0°C and +45°C; charging outside this range may cause performance degradation or safety issues.
- Mandatory BMS and preconditioning: A compatible BMS with over-discharge, over-current, and cell balancing is required, and new batteries must be preconditioned at room temperature before first full cycle.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD excl. heavy equipment). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).