Description
ATOMFAIR® EB200G-0.01G-02 HIGH-PRECISION LABORATORY ELECTRONIC BALANCESCI-GRADE MEASUREMENT DEVICE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The electronic balance requires a stable, vibration-free environment to maintain metrology accuracy. The lithium battery must be charged regularly and the device must not exceed its maximum capacity to prevent structural damage.
- Vibration Sensitivity: The balance incorporates 4-stage dynamic shockproofing but should be placed on a dedicated anti-vibration table for optimal performance.
- Electromagnetic Interference: The balance's internal structural checks control electromagnetic interference, so avoid operating near large transformers or radio transmitters.
- Overload Protection: Do not load the pan beyond 200 g; even with built-in overload protection, exceeding the capacity may damage the sensor.
- Battery Maintenance: Recharge the polymer lithium battery using only the supplied adapter and avoid complete discharge to prolong service life.
- Calibration Stability: The 9-level adjustable speed filters allow the user to match the stabilization response to ambient conditions for consistent readings.
Follow this procedure to set up and use the balance for accurate weighing. The steps cover power-on, calibration, and data recording.
Required Equipment: Weighing pan, AC power adapter
- Position the Balance
Place the balance on a level, vibration-free workbench and connect the AC power adapter. - Power On
Press the power button to turn on the balance and wait for the display to complete the initialization sequence. - Zero Calibration
Perform zero calibration by pressing the tare button once the display shows the zero reading. - Adjust Stabilization
Set the stabilization level using the speed filter buttons to minimize environmental noise for the current conditions. - Select Unit
Select the desired weighing unit using the multi-unit conversion function if required. - Weigh Sample
Place the sample on the pan and allow the reading to stabilize before recording the weight. - Record Data
Record the weight manually or via the RS232 interface by pressing the print key for direct LIMS transfer.
How does the 9-level adjustable stabilization on the ATOMFAIR EB200G-0.01G-02 affect measurement speed versus accuracy?
The 9-level adjustable speed filters allow operators to calibrate the balance's response time against measurement stability. At standard settings, the balance delivers a repeatability of ±0.01g and linearity of ±0.02g, with rapid stabilization. Increasing the stabilization level reduces environmental noise at the cost of slightly longer settling time, while lower levels increase speed but may reduce stability.
Can the EB200G-0.01G-02 electronic balance be integrated with laboratory information management systems (LIMS) via RS232?
Yes, the EB200G-0.01G-02 includes a standard RS232 communication port that provides high-speed physical data streaming output, enabling direct integration with standard LIMS or other laboratory automation hardware. This allows for automated data logging and cross-validation workflows without manual transcription.
What protective features does the ATOMFAIR EB200G-0.01G-02 have to ensure reliable weighing in a busy lab environment?
The balance is equipped with 4-stage dynamic shockproofing to buffer secondary laboratory vibrations, advanced overload protection to safeguard the core transducer from accidental impact, and automated zero tracking to maintain a precise zero-point across serial batches. These features, combined with a high-capacity rechargeable lithium battery for isolated power, ensure reliable performance even in demanding or remote lab settings.
The ATOMFAIR EB200G-0.01G-02 is a 200g capacity electronic balance with 0.01g readability, featuring 9-level stabilization filters, rechargeable battery operation, and RS232 data output. Its robust shockproofing and overload protection suit routine laboratory weighing, but users must account for electromagnetic sensitivity and legacy serial connectivity.
Positive
- Adjustable Stabilization for Rapid Weighing: The 9-level adjustable measurement stabilization allows users to balance speed and stability, optimizing performance for different sample types and reducing wait times in serial weighing operations.
- Dual Power Architecture with Rechargeable Battery: The integrated high-capacity rechargeable lithium polymer battery enables cordless operation in remote or mobile testing environments, while AC power ensures continuous lab use.
Trade-offs
- Sensitivity to Environmental Interference: The compliance notice indicates that electromagnetic and structural interference must be controlled; the balance should be placed on a stable, vibration-free surface away from strong EMI sources to maintain measurement integrity.
- Legacy RS232 Connectivity: The balance provides RS232 serial communication, which may require a USB adapter or dedicated COM port for integration with modern laboratory information systems.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).