Dual-Range EMFC Analytical Balance 210g/120g ATOMFAIR®

$4,074.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Dual-range EMFC analytical balance with 210g/120g capacity, 0.1/0.01mg readability, Φ90 mm pan, RS232 output, and external calibration. Order now.

SKU: AF-EI-B-SMBL-120U-IR07
Category: ,
Brands:

Description

ATOMFAIR® EB210G-0.1MG-R-07 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCE

EXTERNAL CALIBRATION

Product Overview

The ATOMFAIR® EB210G-0.1MG-R-07 Dual-Range Electronic Analytical Balance features state-of-the-art rear-mounted electromagnetic force compensation (EMFC) technology with an optimized manual external calibration workflow. Engineered for advanced institutional analysis, it transitions seamlessly between ten-thousandth and hundred-thousandth resolution modes to overcome subtle ambient drift. Contact our technical desk to explore premium high-stability analytical weighing configurations tailored for rigorous laboratory workflows.

Technical Specifications

EB210G-0.1MG-R-07 EXCLUSIVE PARAMETER SPECIFICATION DETAILS
Model Designation EB210G-0.1MG-R-07
Maximum Capacity Range (g) 210 g / 120 g (Dual-Range Matrix)
Readability Metrics (mg) 0.1 mg / 0.01 mg (Dual-Readability Matrix)
Repeatability Bounds (mg) ±0.6 mg / 0.06 mg
Linearity Deviation (mg) ±0.6 mg / 0.06 mg
Weighing Pan Dimensions (mm) Φ90 mm


FA/FB Series Combined Matrix Specifications

Parameter Model EB210G-0.1MG-D EB210G-0.1MG-R-01 EB210G-0.1MG-R-02 EB210G-0.1MG-R-03 EB210G-0.1MG-R-04 EB210G-0.1MG-R-05 EB210G-0.1MG-R-06 EB210G-0.1MG-R-07
Max Capacity (g) 210 / 32 210 / 52 210 / 82 210 / 120 210 / 32 210 / 52 210 / 82 210 / 120
Readability (mg) 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01
Repeatability (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Linearity (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90
Calibration Variant FA Series: Fully Automated Built-In One-Key Internal Calibration (Timer & Temperature Triggered). FB Series: Standard Configuration External Calibration Framework.


Key Features & Technical Innovations

  • Rear-Mounted EMFC Matrix: Utilizes high-sensitivity, ultra-stable rear-mounted electromagnetic force compensation sensor technology to maximize structural resolution limits.
  • Core Calibration Blueprint: While the companion FA line provides automated internal motorized tuning, the high-efficiency FB variant framework focuses on manual external calibration protocols to guarantee predictable user-verified linearity points.
  • Volumetric Draft Shield Housing: Framed within a large, spacious three-door glass draft shield, granting unrestricted physical loading maneuvers inside an isolated ambient chamber.
  • Dual-Visual Ergonomic Panel: Toggleable background display modes between intense bright and low-light operations, preventing optical strain during extended verification sequences.
  • Multi-Unit Metric Adaptability: Factory-loaded with quick conversion routines supporting Grams (g), Carats (ct), Ounces (oz), precise parts counting, and dry-mass percentage weighing modalities.
  • Comprehensive Guard Systems: Pre-programmed with integrated overload / underload acoustic warnings, structural temperature compensation matrices, and full-range digital taring thresholds.
  • Under-Hook Density Support: Ready for dual-purpose gravimetric configurations, supporting bottom-hook weighing accessories and standard hydrostatic test stands.
  • High-Fidelity Communication Bus: Furnished with a standard RS232 digital output interface to drive automated computer logging loops or peripheral direct lab report printing.

VISUAL HARDWARE: Outfitted with an oversized high-contrast back-lit LCD visual display panel with manual illumination control switches.
ENVIRONMENTAL ALIGNMENT: Outfitted with a front-facing premium bubble spirit level indicator linked to heavy-duty micro-threaded leveling feet.
CRITICAL PRECISION NOTE: For hundred-thousandth semi-micro weighing verification routines (0.01mg), ensure the three-door draft shield housing is entirely sealed. Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

The balance requires a 30-minute pre-heating phase before calibration to stabilize the electromagnetic core. For 0.01mg resolution, the draft shield must be fully sealed to prevent ambient air currents.

  • Pre-heating Requirement: Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
  • Draft Seal Requirement: For hundred-thousandth semi-micro weighing verification routines, ensure the three-door draft shield housing is entirely sealed.
  • Leveling Requirement: Level the balance using the front-facing bubble spirit level indicator and micro-threaded leveling feet to ensure accurate measurements.
  • Temperature Compensation: The balance's structural temperature compensation matrices mitigate ambient drift, but rapid temperature changes should be avoided.
  • Calibration Protocol: The balance uses manual external calibration to verify user-verified linearity points.

Follow these steps to prepare the balance for accurate operation. The initialization process includes leveling, pre-heating, and calibration.

Required Equipment: External calibration weight

  1. Level the balance
    Level the balance using the front-facing bubble spirit level indicator and micro-threaded leveling feet until the bubble is centered.
  2. Power on and pre-heat
    Power on the balance and allow the system to pre-heat for 30 minutes to stabilize the electromagnetic core.
  3. Seal the draft shield
    Ensure the three-door draft shield housing is entirely sealed to prevent ambient air currents during high-resolution weighing.
  4. Perform external calibration
    Perform manual external calibration using the appropriate calibration weight to verify linearity points.
  5. Confirm readiness
    Confirm the balance is ready for use by checking the display for stable readings.

What is the practical trade-off between using the 0.1 mg and 0.01 mg readability modes on the EB210G-0.1MG-R-07?

The 0.1 mg mode supports the full 210 g capacity, while the 0.01 mg mode is limited to 120 g. Repeatability is ±0.6 mg in the higher-capacity mode versus ±0.06 mg in the semi-micro mode, and linearity follows the same ±0.6 mg / 0.06 mg split. To achieve 0.01 mg readability, the draft shield must be completely sealed and the balance must undergo a 30-minute pre-heating phase for sensor equilibrium, making the lower-capacity, higher-precision mode suitable only for small samples under stable ambient conditions.

Can the EB210G-0.1MG-R-07 be integrated with a laboratory computer or printer for automated data recording?

Yes, the balance is equipped with a standard RS232 digital output interface that supports automated computer logging loops or direct peripheral lab report printing. This allows seamless integration into existing data acquisition workflows without requiring additional adapters for serial communication.

What environmental and operational conditions are required to reliably achieve 0.01 mg semi-micro weighing on the EB210G-0.1MG-R-07?

For hundred-thousandth weighing at 0.01 mg readability, the three-door glass draft shield must be entirely sealed to isolate the chamber from ambient air currents and temperature fluctuations. Additionally, a 30-minute system pre-heating phase is mandatory to allow the electromagnetic core to reach full equilibrium before initiating calibration sequences. The balance also features structural temperature compensation to mitigate drift under changing conditions.

The ATOMFAIR EB210G-0.1MG-R-07 is a dual-range analytical balance offering 210g/120g capacity and 0.1mg/0.01mg readability via rear-mounted EMFC technology. It requires manual external calibration and strict environmental controls—including a sealed draft shield and 30-minute pre-heating—to achieve the highest-resolution mode, making it suited for laboratories that can accommodate these operational conditions.

Positive

  • Dual-range high-resolution capability: The balance operates at 210g / 0.1mg and 120g / 0.01mg, enabling both standard analytical and semi-micro weighing without requiring a separate instrument.
  • Rear-mounted EMFC sensor design: The rear-mounted electromagnetic force compensation sensor minimizes front-panel thermal and mechanical disturbances, improving long-term measurement stability.

Trade-offs

  • External calibration required: This FB-series model uses manual external calibration, requiring user access to certified calibration weights and introducing potential operator-dependent variability.
  • Strict environmental setup for 0.01mg mode: To achieve 0.01mg readability, the draft shield must be fully sealed and the instrument must undergo a 30-minute pre-heating phase, adding time and demanding a controlled lab environment.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.