Touchscreen Analytical Balance 520g 1mg RS232 ATOMFAIR®

$1,808.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade touchscreen analytical balance with 520 g capacity, 1 mg readability, ±1 mg repeatability, Φ90 mm pan, and RS232 output. Order now.

SKU: AF-EI-B-ANLB-520M-IR91
Category: ,

Description

ATOMFAIR® EB520G-1MG-I TOUCHSCREEN ELECTRONIC ANALYTICAL BALANCE

RESEARCH GRADE

Product Overview

The ATOMFAIR® EB520G-1MG-I Touchscreen Electronic Analytical Balance delivers exceptional cell-to-cell consistency and baseline testing control for critical laboratory applications. Engineered with an advanced full-aluminum high-stability weighing matrix, it ensures complete ambient variable elimination and serves as an ideal calibration and validation platform. Contact us to explore competitive touchscreen analytical balance prices optimized for your precision R&D infrastructure.

Technical Specifications

EB520G-1MG-I EXCLUSIVE PARAMETER SPECIFICATION DETAILS
Maximum Capacity (g) 520 g
Readability (mg) 1 mg
Repeatability (mg) ±1 mg
Linearity (mg) ±2 mg
Pan Size (mm) Φ90 mm
Calibration Type Automatic Internal Calibration


Full Series Model Specifications Matrix

Model Max (g) Read (mg) Repeat (mg) Linear (mg) Pan (mm) Calibration
EB120G-0.1MG-I-01 120 0.1 ±0.1 ±0.2 Φ90 External
EB120G-0.1MG-01 120 0.1 ±0.1 ±0.2 Φ90 Internal
EB220G-0.1MG-I-01 220 0.1 ±0.1 ±0.2 Φ90 External
EB220G-0.1MG-01 220 0.1 ±0.1 ±0.2 Φ90 Internal
EB220G-1MG-I 220 1 ±1 ±2 Φ90 External
EB220G-1MG 220 1 ±1 ±2 Φ90 Internal
EB320G-1MG-I 320 1 ±1 ±2 Φ90 External
EB320G-1MG 320 1 ±1 ±2 Φ90 Internal
EB520G-1MG-I 520 1 ±1 ±2 Φ90 External
EB520G-1MG-01 520 1 ±1 ±2 Φ90 Internal
Manufacturing Rules Processed under strict automatic internal calibration standard compliance conditions.
Alternative Options Explore our comprehensive calibration balance catalog for custom dimensions. For urgent technical configurations or institutional bulk inquiries, please contact our support desk.


Key Features & Advantages

  • Full-Color Large Screen: High-definition true-color TFT LCD display interface, providing exceptionally rich visualization for complex weighing parameters.
  • Full-Screen Touch Operation: Tailored for advanced laboratory environments, allowing flawless tactile responsiveness even when operating with double-layer gloves.
  • Eye-Care User Interface: Integrates an eco-friendly dual Metro color scheme, drastically reducing visual fatigue during long-duration operation.
  • Intelligent Operational Prompts: Loaded with clear workflow guiding notifications to maximize operational efficiency and execution accuracy.
  • Built-In Dedicated Applications: Pre-installed with multiple optimized software routines to seamlessly adapt to diverse weighing task protocols.
  • Screen Protection Design: Outfitted with an integrated display protective shield, offering extra dust-proof and scratch-resistant engineering for a prolonged lifespan.
  • Transportation Shock Protection: Features a robust draft shield glass door safety lock mechanism, mitigating external transit vibrations and impacts.
  • Ultra-Stable Weighing Base: Full-aluminum heavy-duty chassis construction designed to shield the inner core from low-frequency structural vibration interference.
  • Standardized Data Interfaces: Equipped with a factory-standard RS232 output interface, enabling high-fidelity data logging to computers and printers.

APPLICATION SCOPE: High-precision laboratory workflows, academic research centers, glovebox integrations, and heavy-industrial quality inspection matrices.
PACKAGING: Shock-absorbing multi-layer foam packaging crate reinforced with draft shield protective locking clips.
IMPORTANT NOTICE: Ensure the glass door protective safety lock is strictly engaged before any physical relocation or transport. Deploy the full-aluminum leveling feet on a high-stability platform to completely eliminate external low-frequency vibration interference.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

This analytical balance requires precise leveling and vibration isolation for accurate measurements. The glass door safety lock must be engaged during relocation to prevent damage.

  • Leveling Feet Adjustment: The balance must be leveled using the full-aluminum leveling feet on a high-stability platform to eliminate low-frequency vibration interference.
  • Transport Safety Lock: Engage the glass door protective safety lock before any physical relocation or transport of the balance.
  • Screen Protection: The integrated display protective shield should be kept in place to prevent dust and scratch damage.
  • Automatic Internal Calibration: The balance performs automatic internal calibration to maintain accuracy; ensure calibration cycle is completed before critical measurements.
  • Glovebox Integration: The full-screen touch operation is designed for use with double-layer gloves, making it suitable for glovebox environments.

Does the full-screen touch operation of the EB520G-1MG-I maintain reliable responsiveness when used with thick double-layer gloves in a glovebox, and does this design trade off against durability compared to physical keypads?

Yes, the touchscreen is specifically engineered for flawless tactile responsiveness even when operating with double-layer gloves, making it suitable for glovebox integration. Durability concerns are addressed by an integrated display protective shield that provides dust-proof and scratch-resistant protection, extending the lifespan of the touch interface.

Can the EB520G-1MG-I be directly integrated into an existing laboratory data acquisition system via its RS232 interface, and what are the constraints for software compatibility?

The balance is equipped with a factory-standard RS232 output interface enabling high-fidelity data logging to computers and printers. The product description does not specify software protocols or driver requirements, so integration may rely on standard RS232 serial communication; confirm compatibility with your data acquisition system's input specifications.

What specific precautions are required when relocating the EB520G-1MG-I to prevent damage to the weighing mechanism, and what infrastructure setup is needed to eliminate low-frequency vibrations?

Before any relocation, the glass door protective safety lock must be strictly engaged, and the balance should be transported in its shock-absorbing multi-layer foam packaging with draft shield locking clips. For operation, deploy the full-aluminum leveling feet on a high-stability platform to completely eliminate external low-frequency vibration interference, as specified in the operational notice.

The ATOMFAIR EB520G-1MG-I touchscreen analytical balance offers a 520 g capacity with 1 mg readability and automatic internal calibration, housed in a full-aluminum chassis for vibration damping. Its touchscreen interface supports glove operation, but the external calibration variant requires manual weight handling and the glass draft shield demands careful transport lock engagement.

Positive

  • Full-aluminum vibration damping chassis: The heavy-duty aluminum base shields the weighing cell from low-frequency structural vibrations, enabling stable readings in environments with ambient mechanical noise.
  • Glove-compatible touchscreen interface: The full-screen touch operation is designed for flawless tactile responsiveness even with double-layer laboratory gloves, facilitating use in glovebox or cleanroom workflows.

Trade-offs

  • External calibration requires manual weights: This model uses automatic internal calibration, but the series matrix indicates external calibration variants exist; for the EB520G-1MG-I, calibration is internal, yet users must ensure the internal mechanism is maintained per manufacturer guidelines.
  • Draft shield lock required during transport: The glass door protective safety lock must be engaged before any physical relocation to prevent transit vibrations from damaging the draft shield or internal components.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).