Semi-Micro Balance EB82G-01MG-R-01 0.01mg ATOMFAIR®

$1,308.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Dual-range semi-micro balance with 0.01/0.1 mg readability, 82/120 g capacity, internal automated calibration, Φ90 mm pan and ≤5 s stabilization. Order now.

SKU: AF-EI-B-SMBL-120U-IR01
Category: ,

Description

ATOMFAIR® EB82G-01MG-R-01 ANALYTICAL & SEMI-MICRO BALANCE

EB82G-01MG-R-01 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB82G-01MG-R-01 Analytical & Semi-Micro Balance represents a classic rear-mounted electromagnetic force balancing platform integrated with high-sensitivity, premium stability sensors. Engineered with an ultra-rigorous, sophisticated chassis and an expanded spatial draft chamber, this dual-range system satisfies the most demanding laboratory requirements for ultra-precise mass determination, delivering baseline testing control and eliminating measurement drift.

EB82G-01MG-R-01 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 82 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

The balance requires a stable, vibration-free environment with ambient temperature between 10°C and 33°C and relative humidity between 20% and 80%. A mandatory warm-up period of 30 to 60 minutes after power-on is necessary before performing zeroing, calibration, or sample measurements.

  • Temperature Constraint: Operate within 10°C to 33°C to maintain specified accuracy and repeatability.
  • Humidity Constraint: Maintain relative humidity between 20% and 80% to prevent condensation and electronic drift.
  • Warm-up Requirement: Allow the balance to warm up for 30–60 minutes after power engagement before any measurement or calibration.
  • Calibration Trigger: Internal calibration is automatically initiated when ambient temperature changes by ≥1.5°C or when two hours have elapsed since last calibration; manual override is available.
  • Vibration Isolation: Use the split-body architecture to isolate the weighing cell from hand-induced vibrations; place the display unit away from the balance base.

This procedure guides the user through initial placement, warm-up, and calibration to ensure accurate mass measurement. Following these steps minimizes drift and maximizes repeatability.

Required Equipment: Internal calibration weight (integrated), Draft shield (transparent glass)

  1. Position the balance
    Place the balance base on a rigid, level surface away from drafts, vibrations, and direct sunlight.
  2. Warm up the instrument
    Connect the power adapter and allow the balance to warm up for at least 30 minutes (60 minutes recommended).
  3. Perform internal calibration
    Initiate the internal calibration sequence via the control panel or allow automatic calibration to occur when triggered by temperature or time.
  4. Zero the display
    Press the tare or zero button to zero the display with the empty weighing pan.
  5. Measure the sample
    Carefully place the sample on the pan and read the stable mass after the stabilization indicator appears.

How do the readability and capacity trade off between the two operating ranges of the EB82G-01MG-R-01 balance?

In the fine range, readability is 0.01 mg with a maximum capacity of 82 g, repeatability of ±0.02 mg, and linearity of ±0.02 mg. In the coarse range, readability is 0.1 mg with capacity extended to 120 g, repeatability of ±0.1 mg, and linearity of ±0.1 mg. The balance automatically switches between these dual-range matrices based on load.

What environmental conditions must be maintained for the EB82G-01MG-R-01 to achieve its specified accuracy and stability?

Operating temperature must be between 10°C and 33°C, and relative humidity between 20% and 80% RH. The balance's internal isbl calibration automatically executes if the ambient temperature fluctuates by ≥1.5°C or if more than 2 hours have elapsed, ensuring compensation for environmental drift.

Why is a 30–60 minute warm-up period mandatory before using the EB82G-01MG-R-01 for precise measurements?

The mandatory preheating threshold of 30 to 60 minutes following power-on initialization is required to allow the internal electromagnetic force sensor and electronics to thermally stabilize. This eliminates measurement drift and maintains sensor linearity, which is critical for achieving the specified repeatability of ±0.02 mg in the fine range.

The EB82G-01MG-R-01 analytical and semi-micro balance delivers dual-range readability of 0.01 mg and 0.1 mg with an internal automated calibration system (isbl) that activates upon temperature changes ≥1.5°C or after 2 hours, ensuring drift-free operation. Its split-body architecture isolates user-induced vibration, while the rear-mounted electromagnetic sensor and ≤5-second stabilization support high-throughput precision weighing in controlled laboratory environments.

Positive

  • Dual-range high precision: Provides two readability levels (0.01 mg and 0.1 mg) with corresponding maximum capacities of 82 g and 120 g, allowing single-instrument adaptation to both analytical and semi-micro weighing tasks.
  • Internal automated calibration: The isbl system automates recalibration when ambient temperature shifts by ≥1.5°C or after 2 hours of operation, maintaining measurement traceability without manual intervention.

Trade-offs

  • Mandatory warm-up period: Requires 30 to 60 minutes of power-on stabilization before use to achieve thermal equilibrium within the sensor module; premature operation may compromise linearity and repeatability.
  • Environmental sensitivity: Operates reliably only within 10°C to 33°C and 20% to 80% RH; fluctuations outside this band can degrade measurement stability and trigger frequent recalibration cycles.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.