Semi-Micro Analytical Balance 0.01mg 82/210g ATOMFAIR®

$1,308.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Semi-micro analytical balance with 0.01 mg readability, 82/210 g capacity, ±0.02 mg repeatability, external calibration, and ≤2.5 s stabilization. Order now.

SKU: AF-EI-B-SMBL-210U-ER03
Category: ,

Description

ATOMFAIR® EB82G-01MG-R-03 SEMI-MICRO ANALYTICAL BALANCE

EB82G-01MG-R-03 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB82G-01MG-R-03 Semi-Micro Analytical Balance represents an advanced external weight calibration balancing platform integrated with high-sensitivity, high-resolution electromagnetic force compensation core sensors. Engineered with an optimized volumetric footprint and enhanced spatial air shielding, this high-precision system satisfies the most demanding laboratory requirements for trace mass determination, delivering baseline kinetic response stabilization within 2.5 seconds under rigorous scientific testing criteria.

EB82G-01MG-R-03 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Product Classification Semi-Micro Analytical Balance (External Weight Calibration)
Readability Division Value (d) 0.01 mg
Maximum Scale Capacity (Max) 82 g / 210 g
Repeatability Deviation Error ±0.02 mg
Linearity Distortion Error ±0.02 mg
Typical Calibration Weight 10 g
Average Stabilization Response Time ≤ 2.5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 80 mm
Outer Structural Dimensions 470 mm × 310 mm × 330 mm
Draft Shield Internal Width 230 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 18°C ~ 23°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Grid Matrix Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Semi-Micro Analytical Balances Portfolio Comparison Matrix

SPECIFICATION ITEM EB31-120G-01MG-R EB51-120G-01MG-R EB82-120G-01MG-R EB31-210G-01MG-R EB51-210G-01MG-R EB82G-01MG-R-03 ES1205B
Readability Value (d) 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg
Max Capacity Threshold (Max) 31/120g 51/120g 82/120g 31/210g 51/210g 82/210g 120g
Repeatability Deviation Error ±0.02 mg (Full Portfolio Standardized)
Linearity Deviation Error ±0.02 mg (Full Portfolio Standardized)
Typical Calibration Weight 10 g (External Reference Mass Threshold)
Stabilization Time (Average) ≤ 2.5 Seconds Dynamic Stabilization Response
Chassis Geometries & Sizes Pan Size: Φ 80 mm | Internal Draft Shield: 230 mm | Outer Body Structure: 470 × 310 × 330 mm
Operational Constraints Ambient Thermal Range: 18°C ~ 23°C | Workspace Moisture Matrix: 20% ~ 80% RH
Power Subsystem Architecture Global Grid Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Electronic Analytical Balances Portfolio Comparison Matrix

SPECIFICATION ITEM EB120G-0.1MG-02 EB210G-0.1MG-01 EB220G-0.1MG-02 EB320G-0.1MG-01 EB120G-0.1MG-I-01 EB210G-0.1MG-I EB220G-0.1MG-I-02
Readability Value (d) 0.1 mg
Max Capacity Threshold (Max) 120g 210g 220g 120g 210g 220g 320g
Repeatability Deviation Error ±0.1 mg
Linearity Deviation Error ±0.2 mg
Stabilization Time (Average) ≤ 2.5 Seconds Optimized Processing Kinetics
Chassis Geometries & Sizes Pan Size: Φ 80 mm | Internal Draft Shield: 230 mm | Outer Body Structure: 470 × 310 × 330 mm
Operational Constraints Ambient Thermal Range: 18°C ~ 23°C | Workspace Moisture Matrix: 20% ~ 80% RH
Power Subsystem Architecture Global Grid Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Full Series Core Functional Advantages

  • Classic Rear-Mounted Electromagnetic Force Sensor: Delivers exceptional sensitivity, ultra-high resolution kinetics, and stable execution response times under rigorous data verification procedures.
  • Detachable Displaying Control Architecture (Split-Body Design): Isolates mechanical hand operation micro-vibrations from the foundational weighing block while facilitating multi-angle optical line-of-sight checks.
  • Extendable Angled LED Display Panel: Provides crystal-clear, high-brightness data visibility paired with an optimized UI layout to minimize user reading errors.
  • Panoramic Transparent Glass Draft Shield: Yields all-around tracking visibility of analytical specimens while utilizing advanced structural components for swift disassembly, cleaning, and decontamination.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard weight measurement, trace percentage determination, and granular item piece counting.
  • Instantaneous Multi-Unit Conversions: Seamlessly transfers readouts between global scientific units including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math overhead.
  • Optimized Trace Micro-Addition Processing: Advanced micro-sampling digital filtering technology stabilizes data readouts against ambient drift, perfectly capturing minute powder or fluid specimen additions.
  • Integrated Bidirectional RS232 Communication Bus: Establishes standard hardware pipelines to micro-printers, lab host computer terminals, and third-party LIMS management systems.
  • Autonomous Fully Automatic Calibration Subsystem: Instantly triggers system recalibration if local temperature variations swing >1.5°C or if time elapsed exceeds 2 hours, drastically mitigating environmental error overhead.

APPLICATION SCOPE: Premium semi-micro target validation, analytical chemistry powder sampling, external calibration compliance workflows, and multi-range verification pipelines.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised semi-micro resolution linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, external calibration mass loading, or trace specimen additions.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

This semi-micro analytical balance requires controlled environmental conditions and mandatory preheating to achieve specified metrological performance. Operational constraints include temperature stability, humidity limits, and external calibration procedures.

  • Environmental stability requirement: Operate within 18°C to 23°C and 20% to 80% relative humidity to maintain accuracy and repeatability.
  • Preheating threshold: Allow 30 to 60 minutes of warm-up time after power-on before performing any zeroing, calibration, or sample measurement.
  • Automatic recalibration trigger: Recalibration is automatically initiated when ambient temperature changes exceed 1.5°C or when two hours have elapsed since the last calibration.
  • Stabilization response time: Allow a stabilization period of up to 2.5 seconds after sample placement before recording the mass reading.
  • External calibration protocol: Use a 10-gram external calibration weight to correct for environmental drift and maintain linearity.

Proper initialization and calibration procedures are critical for accurate mass determination. Follow these steps to prepare the balance for measurement.

Required Equipment: External calibration weight (10 g)

  1. Power-on and warm-up
    Connect the balance to the power supply and allow it to warm up for at least 30 minutes before use.
  2. Verify environmental conditions
    Confirm that the ambient temperature is between 18°C and 23°C and relative humidity is between 20% and 80%.
  3. Perform zero adjustment
    Ensure the weighing pan is empty, close the draft shield, and press the tare or zero button to reset the display.
  4. Execute external calibration
    Place the 10-gram calibration weight on the pan, close the draft shield, and initiate the external calibration routine.
  5. Load sample and record measurement
    Place the sample on the pan, close the draft shield, wait for the stabilization indicator, and record the displayed mass.

How does the dual-range maximum capacity of 82 g and 210 g affect repeatability and linearity on the EB82G-01MG-R-03?

The EB82G-01MG-R-03 maintains a repeatability deviation error of ±0.02 mg and a linearity distortion error of ±0.02 mg across both capacity ranges (82 g and 210 g), as specified in the target model profile. This means switching between the lower and upper range does not degrade precision, making it suitable for trace mass determination from sub-milligram samples up to 210 g without recalibrating for range transitions.

Can the EB82G-01MG-R-03 be integrated with a laboratory information management system (LIMS) or external printer?

Yes, the EB82G-01MG-R-03 includes an integrated bidirectional RS232 communication bus that establishes standard hardware pipelines to micro-printers, lab host computer terminals, and third-party LIMS management systems. This allows direct data transfer and automated documentation without manual transcription.

What are the mandatory preheating and environmental requirements to maintain 0.01 mg readability on the EB82G-01MG-R-03?

The balance requires a mandatory preheating threshold of 30 to 60 minutes following power-on initialization before performing operational zeroing or external calibration mass loading. Operating environmental temperature must be maintained between 18°C and 23°C with workspace humidity between 20% and 80% RH to preserve uncompromised semi-micro resolution linearity.

The EB82G-01MG-R-03 semi-micro analytical balance delivers 0.01 mg readability with dual-range capacity (82 g / 210 g) and ≤2.5 s stabilization, but requires a 30–60 minute warm-up and strict environmental control (18–23°C, 20–80% RH) to maintain ±0.02 mg repeatability and linearity.

Positive

  • Dual-range capacity with 0.01 mg readability: Provides 82 g and 210 g maximum capacity thresholds at 0.01 mg readability, enabling trace mass determination across a wide sample mass range without switching instruments.
  • Fast stabilization under 2.5 seconds: Average stabilization response time ≤2.5 seconds reduces measurement cycle time, improving throughput in high-volume analytical workflows.

Trade-offs

  • Mandatory 30–60 minute warm-up period: Requires 30–60 minutes of power-on initialization before calibration or specimen loading to preserve semi-micro resolution linearity, delaying immediate use.
  • Narrow operating temperature and humidity range: Operates reliably only within 18–23°C and 20–80% RH; deviations may degrade repeatability and linearity, necessitating climate-controlled laboratory infrastructure.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).