Precision Analytical Balance EB110G 110g 0.1mg ATOMFAIR®

$902.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Laboratory-grade EB110G-0.1MG analytical balance with 110 g capacity, 0.1 mg readability, ±0.1 mg repeatability, Φ90 mm pan, and glass draft shield. Order now.

SKU: AF-EI-B-ANLB-110A-NN06
Category: ,

Description

ATOMFAIR® EB110G-0.1MG HIGH-PRECISION ANALYTICAL BALANCE

LABORATORY INSTRUMENT GRADE

Product Overview

The ATOMFAIR® EB110G-0.1MG Precision Analytical Balance establishes professional 0.1mg readability baselines for rigorous scientific workflows, advanced laboratory metrology, and high-purity material verification. Engineered with robust anti-vibration architecture to isolate external metrics noise, this unit ensures uncompromised reliability across trace sample tracking assays. For global institutional setups requiring specific framework matrices, connect with our sales team for tailored volume quotes.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Metrology Design (EB110G-0.1MG Exclusive)
Product Model EB110G-0.1MG
Maximum Capacity 110 g
Readability 0.1 mg (0.0001 g)
Repeatability ±0.1 mg
Linearity Error ±0.2 mg
Pan Size Φ90 mm

Key Features & Advantages

  • Premium Industrial Ergonomics: Highly resilient, corrosion-proof, and impact-resistant ABS engineering plastic chassis structure balances structural stability with lightweight laboratory relocation.
  • Advanced Cross-Current Blockers: Features an integrated four-sided transparent glass draft shield, aluminum alloy backplate, and an specialized under-pan airflow breeze shield to fully secure the analytical chamber.
  • Vibration Suppression Architecture: Solid full-aluminum base foundation actively eliminates ambient parasitic low-frequency vibrations, complemented by 4-level anti-shock adaptation and tunable response metrics speeds.
  • Versatile Operational Capabilities: Supports dual-mode piece counting, percentage metric weighing, direct universal multi-unit conversions (g, oz, ct), and a built-in internal below-balance underhook setup.
  • Total Mechanism Security Safeguards: Mechanical glass door transport lock, display screen protective dust guard, automatic zero-tracking calibration, and smart fault diagnostics guarantee robust operational longevity.


2. FA Series Full Analytical Matrix Parameters
Model EB100G-0.1MG EB110G-0.1MG EB160G-0.1MG EB200G-0.1MG-01 EB210G-0.1MG-02 EB60G-0.1MG-R EB120G-0.1MG-03 EB220G-0.1MG-03 EB320G-0.1MG-02
Max Cap (g) 100 110 160 200 210 60/210 120 220 320
Readability (mg) 0.1 0.1 0.1 0.1 0.1 0.1/1 0.1 0.1 0.1
Repeat (mg) ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1/±1 ±0.1 ±0.1 ±0.1
Linear (mg) ±0.2 ±0.2 ±0.2 ±0.2 ±0.2 ±0.2/±2 ±0.2 ±0.2 ±0.2
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90

APPLICATION SCOPE: Trace quantitative chemistry analysis, solid-state cell boundary validation, precise material science workflows, and micro-sample auditing.
PACKAGING: Shock-absorbent industrial shipping enclosure paired with integrated glass transit locks and dust protective covers.
IMPORTANT NOTICE: This 0.1mg sub-milligram metrology balance must be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation. Never move the device without activating the glass door transport security mechanism.
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

This document outlines the mandatory operational constraints for the ATOMFAIR EB110G-0.1MG high-precision analytical balance. The instrument must be leveled on an anti-vibration stone table, pre-warmed before use, and the transport lock engaged prior to any movement.

  • Leveling on Anti-vibration Surface: The balance must be placed on a level, anti-vibration stone table to ensure accurate measurements.
  • Pre-warming Requirement: The balance must be pre-warmed according to the manufacturer's specifications before operation.
  • Transport Lock Activation: The glass door transport lock must be activated before moving the balance to prevent damage.

This procedure details the required setup and handling steps for the ATOMFAIR EB110G-0.1MG analytical balance. Adhering to these steps ensures measurement accuracy and prevents equipment damage.

Required Equipment: Anti-vibration stone table

  1. Level the balance
    Level the balance on an anti-vibration stone table.
  2. Pre-warm the balance
    Pre-warm the balance according to the manufacturer's specifications.
  3. Engage transport lock
    Activate the glass door transport lock before moving the balance.

Does adjusting the anti-shock level on the EB110G-0.1MG trade off measurement speed for improved stability at 0.1 mg readability?

Yes. The balance features 4-level anti-shock adaptation with tunable response speeds, meaning higher anti-shock settings increase stability at the expense of measurement speed. This trade-off is critical for maintaining the specified repeatability of ±0.1 mg and linearity of ±0.2 mg in vibration-prone environments.

What are the operational constraints when using the below-balance weighing hook on the EB110G-0.1MG analytical balance?

The EB110G-0.1MG includes a built-in internal below-balance underhook for density or magnetic measurements. Constraints include the need for a leveled anti-vibration stone table, the glass door transport lock must be disengaged only when stationary, and the under-pan airflow breeze shield must remain in place to avoid cross-current interference at 0.1 mg readability.

What infrastructure and pre-conditioning steps are required before first use of the EB110G-0.1MG analytical balance?

The balance must be placed on a dedicated anti-vibration stone table and completely leveled. A specified pre-warming period is mandatory before operation to achieve stable 0.1 mg readings. Additionally, the glass door transport lock must be activated whenever the device is moved to prevent mechanical damage to the analytical chamber.

The EB110G-0.1MG analytical balance offers 0.1 mg readability with a 110 g capacity, featuring robust vibration suppression via a full-aluminum base and 4-level anti-shock adaptation, plus a four-sided glass draft shield with under-pan airflow blocker. However, it requires leveling on an anti-vibration stone table and pre-warming before use, and the glass door transport lock must be engaged during relocation.

Positive

  • Vibration suppression architecture: Solid full-aluminum base foundation with 4-level anti-shock adaptation and tunable response speeds actively dampens ambient low-frequency vibrations.
  • Integrated draft shield isolation: Four-sided transparent glass draft shield with aluminum backplate and under-pan airflow breeze shield fully secures the weighing chamber from cross-currents.

Trade-offs

  • Requires specialized mounting surface: This 0.1 mg balance must be completely leveled on an anti-vibration stone table and pre-warmed according to specifications before operation to maintain metrology accuracy.
  • Transport lock mandatory during moves: The glass door transport security mechanism must be engaged before any movement; failure to do so may damage the delicate weighing cell or draft shield assembly.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).