Analytical Balance FA2055 Dual-Range 0.01mg ATOMFAIR®

$2,534.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Research-grade FA2055 analytical balance with EMFC, 210 g/52 g dual range, 0.1/0.01 mg readability, internal calibration, Φ90 mm pan. Order now.

SKU: AF-EI-B-SMBL-NS0U-IR16
Category: ,

Description

ATOMFAIR® FA2055 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCE

RESEARCH GRADE

Product Overview

The ATOMFAIR® FA2055 Dual-Range Electronic Analytical Balance features state-of-the-art rear-mounted electromagnetic force compensation (EMFC) technology. Engineered for advanced institutional analysis, it transitions seamlessly between ten-thousandth and hundred-thousandth resolution modes to overcome subtle ambient drift. Contact our technical desk to explore premium high-stability analytical weighing configurations tailored for rigorous laboratory workflows.

Technical Specifications

FA2055 EXCLUSIVE PARAMETER SPECIFICATION DETAILS
Model Designation FA2055
Maximum Capacity Range (g) 210 g / 52 g (Dual-Range Matrix)
Readability Metrics (mg) 0.1 mg / 0.01 mg (Dual-Readability Matrix)
Repeatability Bounds (mg) ±0.6 mg / 0.06 mg
Linearity Deviation (mg) ±0.6 mg / 0.06 mg
Weighing Pan Dimensions (mm) Φ90 mm


FA/FB Series Combined Matrix Specifications

Parameter Model FA2035 FA2055 FA2085 FA2125 FB2035 FB2055 FB2085 FB2125
Max Capacity (g) 210 / 32 210 / 52 210 / 82 210 / 120 210 / 32 210 / 52 210 / 82 210 / 120
Readability (mg) 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01 0.1 / 0.01
Repeatability (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Linearity (mg) ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06 ±0.6 / 0.06
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90
Calibration Variant FA Series: Fully Automated Built-In One-Key Internal Calibration (Timer & Temperature Triggered). FB Series: Standard Configuration External Calibration Framework.


Key Features & Technical Innovations

  • Rear-Mounted EMFC Matrix: Utilizes high-sensitivity, ultra-stable rear-mounted electromagnetic force compensation sensor technology to maximize structural resolution limits.
  • Automated Internal Self-Calibration: FA variants deliver one-key fully automated internal calibration triggered by timed schedule intervals or active ambient temperature fluctuations, neutralizing mechanical measurement errors without standard weights handling.
  • Volumetric Draft Shield Housing: Framed within a large, spacious three-door glass draft shield, granting unrestricted physical loading maneuvers inside an isolated ambient chamber.
  • Dual-Visual Ergonomic Panel: Toggleable background display modes between intense bright and low-light operations, preventing optical strain during extended verification sequences.
  • Multi-Unit Metric Adaptability: Factory-loaded with quick conversion routines supporting Grams (g), Carats (ct), Ounces (oz), precise parts counting, and dry-mass percentage weighing modalities.
  • Comprehensive Guard Systems: Pre-programmed with integrated overload / underload acoustic warnings, structural temperature compensation matrices, and full-range digital taring thresholds.
  • Under-Hook Density Support: Ready for dual-purpose gravimetric configurations, supporting bottom-hook weighing accessories and standard hydrostatic test stands.
  • High-Fidelity Communication Bus: Furnished with a standard RS232 digital output interface to drive automated computer logging loops or peripheral direct lab report printing.

VISUAL HARDWARE: Outfitted with an oversized high-contrast back-lit LCD visual display panel with manual illumination control switches.
ENVIRONMENTAL ALIGNMENT: Outfitted with a front-facing premium bubble spirit level indicator linked to heavy-duty micro-threaded leveling feet.
CRITICAL PRECISION NOTE: For hundred-thousandth semi-micro weighing verification routines (0.01mg), ensure the three-door draft shield housing is entirely sealed. Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

Operate the balance on a stable, vibration-free surface with the draft shield fully sealed when using 0.01 mg readability. Allow a 30-minute pre-heating period after power-on to achieve electromagnetic core equilibrium before initiating calibration.

  • Leveling Procedure: Adjust the leveling feet until the bubble spirit level indicates the balance is perfectly horizontal.
  • Draft Shield Sealing: Confirm all three draft shield doors are closed during high-resolution weighing to eliminate air currents.
  • Thermal Stabilization: Wait 30 minutes after powering on for the internal electromagnetic sensor to reach thermal equilibrium.
  • Calibration Activation: Initiate the one-key internal calibration either manually or via automatic timer/temperature triggers to maintain precision.

This procedure describes how to set up and calibrate the balance for accurate weighing. Follow these steps after placing the balance on a stable bench and connecting power.

Required Equipment: Leveling feet, Draft shield doors, Calibration key

  1. Level the balance
    Adjust the four leveling feet until the bubble spirit level indicates the balance is perfectly horizontal.
  2. Connect power and warm up
    Connect the balance to a power source and allow it to warm up for 30 minutes to stabilize the electromagnetic sensor.
  3. Seal the draft shield
    Ensure all three draft shield doors are fully closed to isolate the weighing chamber from drafts.
  4. Initiate calibration
    Press the CAL key to trigger the internal calibration routine, which compensates for temperature and time drift.
  5. Verify calibration
    Check that the balance displays the calibration confirmation and zero reading before proceeding with measurements.

How does the dual-range measurement capability of the ATOMFAIR FA2055 balance affect repeatability and linearity when operating at the higher 0.01 mg readability?

At the 0.01 mg readability level (max capacity 52 g), the FA2055 delivers a repeatability of ±0.06 mg and linearity deviation of ±0.06 mg. When switched to the standard 0.1 mg readability range (max capacity 210 g), both repeatability and linearity shift to ±0.6 mg. This trade-off allows researchers to choose between ultra-fine resolution for small samples or higher capacity with slightly relaxed precision.

What external data communication options does the FA2055 offer for integration into automated laboratory workflows?

The FA2055 is equipped with a standard RS232 digital output interface for direct connection to computer logging systems or peripheral lab printers. Additionally, it supports an under-hook weighing configuration for hydrostatic density kits, enabling gravimetric density measurements without requiring separate hardware.

What specific operational steps are required to reliably achieve the 0.01 mg semi-micro weighing accuracy on the FA2055 balance?

For 0.01 mg measurements, the three-door glass draft shield must be completely sealed to isolate the pan from ambient air currents and thermal drift. A 30-minute system pre-heating phase is mandatory to allow the electromagnetic force compensation core to reach thermal equilibrium before starting calibration. The balance also incorporates temperature-compensated internal calibration (timer or temperature-triggered) and front-accessible leveling feet with a bubble spirit indicator for proper horizontal alignment.

The ATOMFAIR FA2055 dual-range analytical balance combines rear-mounted EMFC sensor technology with fully automated internal calibration (timer/temperature triggered) to deliver 0.1 mg and 0.01 mg readability across 210 g and 52 g capacity ranges, housed in a volumetric three-door draft shield with RS232 output.

Positive

  • Dual-range EMFC with auto-calibration: Rear-mounted electromagnetic force compensation sensor enables seamless switching between 0.1 mg and 0.01 mg readability; fully automated internal calibration triggered by timer or ambient temperature fluctuations eliminates manual weight handling errors.
  • Volumetric draft shield and ergonomic display: Large three-door glass draft shield isolates the weighing chamber from ambient air currents; toggleable high-contrast LCD panel reduces optical strain during extended verification sequences.

Trade-offs

  • 30-minute pre-heat for semi-micro mode: To achieve 0.01 mg readability, the draft shield must be fully sealed and the balance requires a 30-minute system pre-heating phase for the electromagnetic core to reach thermal equilibrium before calibration.
  • Temperature-sensitive calibration triggers: Automated internal calibration activates on ambient temperature fluctuations, requiring stable environmental conditions to avoid unnecessary recalibration cycles during routine weighing.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).