Description
ATOMFAIR® EB120G-0.1MG-D ELECTRONIC DENSITY ANALYTICAL BALANCEDENSITY METRIC DIVISION
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This balance requires the measured sample to have an air weight of at least 0.25 g and a buoyant lift in liquid not exceeding -0.125 g to preserve measurement integrity. The precision of density readings is directly tied to the balance's readability, ensuring decimal consistency across mass and density outputs.
- Minimum Air Weight Requirement: The sample must have an air weight of ≥ 0.25 g to prevent mathematical scaling drops during density evaluation.
- Maximum Buoyancy Limit: The total buoyant lift of the sample in the liquid must be ≤ -0.125 g to maintain valid Archimedes displacement readings.
- Density Precision Dependency: The effective decimal places of density measurements (g/cm³) are strictly paired with the baseline readability metrics of the integrated balance frame.
- Reference Plummet for Liquid Density: Liquid density evaluations require the use of the included high-purity stainless steel reference plummet for rapid immersion validation.
- Compatible Material States: The balance supports density testing for both solid and liquid materials under Archimedes liquid displacement protocols.
How does the EB120G-0.1MG-D's 0.1 mg readability constrain the minimum sample size for density measurement, and what is the buoyancy limit that affects measurement range?
The minimum sample weight in air must be ≥ 0.25 g, and the maximum buoyancy in water must be ≤ -0.125 g. These thresholds ensure the 0.1 mg readability can resolve density differences without mathematical drift. Samples below these limits risk measurement errors due to insufficient signal-to-noise ratio.
What specific material classes are compatible with the EB120G-0.1MG-D density balance for solid and liquid density testing?
The balance is verified for polymers, alloy complexes, technical glass compounds, technical fluid dynamics, and structured metallurgy products. It includes a stainless steel reference plummet for liquid immersion validation. Both solids and liquids are supported, but samples must meet the minimum air weight (≥0.25 g) and maximum buoyancy (≤ -0.125 g) limits.
What critical operational boundaries must be observed when using the EB120G-0.1MG-D to prevent measurement errors?
To preserve measurement integrity, ensure the sample air weight is ≥ 0.25 g and its buoyant lift in the liquid is ≤ -0.125 g. The balance is factory-fitted with a display protective shield against dust and scratches, but no additional environmental controls are specified. Density precision pairs directly with the balance's 0.1 mg readability, so proper calibration is required.
The ATOMFAIR® EB120G-0.1MG-D Electronic Density Analytical Balance offers synchronized high-precision density measurements based on Archimedes principle, with a readability of 0.1 mg and a maximum capacity of 120 g. However, it imposes strict sample weight and buoyancy limits (air weight ≥ 0.25 g, buoyancy ≤ -0.125 g) and its density precision is inherently bound by the balance's readability.
Positive
- Synchronized High-Precision Density Output: The density result (g/cm³) maintains exact decimal consistency with the balance resolution, ensuring reliable and accurate density measurements.
- Archimedes Displacement Integration: Leverages hydro-displacement concepts for seamless solid and liquid evaluations with prompt, error-free direct data outputs and zero volatile mathematical drift.
Trade-offs
- Strict Sample Weight and Buoyancy Limits: Measured target must have air weight ≥ 0.25 g and total buoyant lift ≤ -0.125 g to maintain matrix integrity and prevent mathematical scaling drops.
- Density Precision Tied to Balance Readability: The effective decimal places of density measurements are strictly paired with the baseline readability metrics of the integrated balance frame, limiting density resolution to the balance's readability.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).