Electronic Balance EB410G-0.001G-02 410 g ATOMFAIR®

$967.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Laboratory-grade EB410G-0.001G-02 electronic balance with 410 g capacity, 1 mg readability, ±1 mg repeatability, Φ90 mm pan, and glass draft shield. Order now.

SKU: AF-EI-B-PELB-410M-NN02
Category: ,

Description

ATOMFAIR® EB410G-0.001G-02 HIGH-PRECISION ELECTRONIC BALANCE

LABORATORY INSTRUMENT GRADE

Product Overview

The ATOMFAIR® EB410G-0.001G-02 Precision Electronic Balance establishes high-accuracy baselines for scientific workflows, laboratory weighing, and material phase-pure verification. Designed to eliminate environmental measurement variables, this instrument provides reliable cell-to-cell consistency and ultra-stable performance thresholds. For research teams looking to secure competitive laboratory analytics, contact us to check the multi-unit matrix testing framework and premium academic wholesale pricing options.

Technical Specifications

PARAMETER DETAILS
1. Core Device & Metrology Design (EB410G-0.001G-02 Exclusive)
Product Model EB410G-0.001G-02
Maximum Capacity 410 g
Readability 1 mg (0.001 g)
Repeatability ±1 mg
Linearity Error ±2 mg
Pan Size Φ90 mm

Key Features & Advantages

  • Visual Clarity & Touch Sensitivity: Extra-large backlit LCD paired with highly sensitive light-touch keys ensures intuitive calibration and error-free operation.
  • Advanced Environmental Isolation: Equipped with a four-sided transparent glass draft shield, aluminum alloy backplate, and an under-pan airflow breeze break to block parasitic cross-currents.
  • Structural Integrity & Anti-Shock: Solid full-aluminum base suppresses low-frequency ambient vibrations, reinforced with 4-level shock resistance and adjustable stabilization tracking speeds.
  • Multi-Functional Research Platform: Seamlessly supports piece counting, percentage weighing, dynamic below-balance density setups via a built-in underhook, and universal multi-unit matrices (g, oz, ct).
  • Overload Guard & Diagnostics: Automated diagnostic fault tracking, full-range tare thresholds, and a mechanical transit security lock on the glass door safeguard internal validation integrity.

2. JA Series Full Matrix Parameters
Model Max Cap (g) Readability (mg) Repeatability (mg) Linearity (mg) Pan Size (mm)
EB100G-0.001G-01 100 1 ±1 ±2 Φ90
EB120G-0.001G 120 1 ±1 ±2 Φ90
EB200G-1MG 200 1 ±1 ±2 Φ90
EB300G-0.001G-01 300 1 ±1 ±2 Φ90
EB410G-0.001G-02 410 1 ±1 ±2 Φ90
EB500G-0.001G 500 1 ±1 ±2 Φ90
EB620G-0.001G 620 1 ±1 ±2 Φ123
JA10003 (Touch) 1000 1 ±1 ±2 Φ123
Manufacturing Rules Processed under strict ISO 9001 / High-Precision Quality Standard compliance conditions.

APPLICATION SCOPE: Analytical chemistry labs, solid-state electrolyte processing, precise academic research validation, and institutional metrics checking.
PACKAGING: Secure industrial box package integrated with specialized display protective shields and robust door transport locks.
IMPORTANT NOTICE: This precision apparatus must be leveled and calibrated in a vibration-free environment prior to deployment. Always secure the transport security lock before relocating the balance to avoid permanent structural cell degradation.
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

This precision balance requires specific environmental and handling conditions for accurate operation. Failure to observe these constraints may compromise measurement integrity or damage the instrument.

  • Environmental Vibration Isolation: Operate the balance on a stable, vibration-free bench to prevent measurement errors.
  • Leveling Requirement: Level the balance using the adjustable feet and built-in level indicator before each use.
  • Transport Lock Engagement: Engage the transport security lock on the glass door before relocating the balance to prevent permanent structural cell degradation.
  • Draft Shield Usage: Keep the four-sided glass draft shield closed during weighing to block parasitic air currents.
  • Calibration Verification: Perform calibration with a certified weight after leveling and whenever the balance is moved.

Follow these steps to safely set up and use the balance for accurate weighing. Proper initialization ensures reliable measurements and long instrument life.

Required Equipment: Calibration weight set (optional)

  1. Place on stable surface
    Place the balance on a stable, vibration-free workbench away from drafts and heat sources.
  2. Level the balance
    Adjust the leveling feet until the bubble level is centered within the indicator.
  3. Disengage transport lock
    Verify the transport security lock on the glass door is disengaged before powering on.
  4. Power on and warm up
    Press the power button to turn on the balance and allow it to warm up for at least 10 minutes.
  5. Perform calibration
    Perform a calibration cycle using the internal calibration function or an external certified weight.
  6. Tare the balance
    Place an empty container on the pan and press the tare button to zero the reading.
  7. Weigh the sample
    Add the sample to the container and record the stable weight reading displayed on the screen.

How does the 1 mg readability of the EB410G-0.001G-02 balance interact with its ±2 mg linearity error when performing piece counting or percentage weighing applications?

The balance offers 1 mg readability, but linearity error is ±2 mg, meaning that over the full 410 g range, the deviation from true value can be up to 2 mg. For piece counting, this linearity error directly affects the calculated average piece weight, especially when counting small, lightweight items. The instrument's adjustable stabilization tracking speeds allow users to optimize response time versus accuracy, partially mitigating the impact in stable environments.

What conditions are required to achieve the stated ±1 mg repeatability on the EB410G-0.001G-02 when used for below-balance density measurements of solid-state electrolyte pellets?

The balance must be placed on a level, vibration-free surface and calibrated before use. The four-sided glass draft shield and under-pan airflow breeze break are essential to eliminate air currents that can disrupt below-balance measurements. The built-in underhook supports density setups, but the transit security lock must be disengaged and the balance properly leveled to maintain the ±1 mg repeatability specification.

What specific steps should be taken to secure the EB410G-0.001G-02 balance's internal components during laboratory relocation or storage?

The instrument includes a mechanical transit security lock on the glass door that must be engaged before any movement. Additionally, the transport security lock should be secured to prevent permanent structural cell degradation, as stated in the operational notice. The balance should be transported in its original box with protective shields to safeguard the glass and load cell.

The ATOMFAIR EB410G-0.001G-02 delivers 1 mg readability and 410 g capacity with a four-sided glass draft shield and aluminum base for environmental isolation, but demands a vibration-free setup and mandatory transport lock before relocation to avoid sensor damage.

Positive

  • Environmental draft isolation: Four-sided transparent glass draft shield with aluminum alloy backplate and under-pan airflow breeze break minimizes parasitic air currents, improving measurement stability in open lab environments.
  • Vibration-resistant aluminum base: Solid full-aluminum base with 4-level shock resistance and adjustable stabilization tracking speeds suppresses low-frequency ambient vibrations for consistent readings.

Trade-offs

  • Vibration-free installation required: The precision apparatus must be leveled and calibrated in a vibration-free environment prior to deployment, limiting placement options without active vibration isolation.
  • Mandatory transport lock during relocation: The mechanical transit security lock must be engaged before moving the balance to prevent permanent structural cell degradation, adding a procedural step for reconfiguration.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).