Description
ATOMFAIR® EB82G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCEEB82G-01MG-R-02 CORE SPECIFICATION PLATFORM
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This analytical balance requires a 30-60 minute warm-up after power-on to achieve thermal equilibrium and sensor stability. It must be operated within 10-33°C and 20-80% RH to maintain specified repeatability and linearity.
- Warm-up Requirement: Allow the balance to warm up for 30-60 minutes following power-on before performing zeroing, calibration, or sample addition.
- Environmental Stability: Operate the balance within 10-33°C ambient temperature and 20-80% RH to prevent measurement drift and maintain accuracy.
- Automatic Calibration Trigger: The internal isbl calibration executes automatically when ambient temperature fluctuates by ≥1.5°C or when elapsed time exceeds 2 hours.
- Vibration Isolation: Use the split-body architecture to isolate hand-induced micro-vibrations from the weighing chamber for stable readings.
Follow these steps to initialize and operate the balance for accurate mass determination. Proper warm-up and calibration are critical before sample measurement.
Required Equipment: Atomfair EB82G-01MG-R-02 Analytical Balance
- Power On and Warm-Up
Power on the balance and allow 30-60 minutes for warm-up to stabilize the sensor. - Perform Internal Calibration
Initiate internal isbl calibration manually or allow the automatic trigger based on temperature or time. - Zero the Balance
Press the tare or zero key to reset the display before placing any sample. - Add Sample and Record
Place the sample on the pan and wait for the stabilization indicator before recording the mass.
What performance trade-off exists between the two readability ranges (0.01 mg and 0.1 mg) on the EB82G-01MG-R-02 balance, and how does capacity affect measurement precision?
The balance offers dual readability: 0.01 mg for semi-micro precision up to 82 g and 0.1 mg for analytical precision up to 120 g. Repeatability and linearity are ±0.02 mg in the finer range and ±0.1 mg in the coarser range, directly correlating readability with capacity. Users must choose higher capacity (120 g) with 0.1 mg readability or higher precision (0.01 mg) up to 82 g.
Can the EB82G-01MG-R-02 balance be integrated into automated data logging systems without additional hardware?
Yes, the balance includes an integrated RS232 communication bus that supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking. No additional interface hardware is required for serial communication.
What are the mandatory environmental and operational prerequisites for achieving rated precision on the EB82G-01MG-R-02 balance?
The balance requires a mandatory warm-up period of 30–60 minutes after power-on before zeroing or calibration. Operating temperature must be between 10°C and 33°C with 20%–80% relative humidity. The internal automated calibration (isbl) executes if ambient temperature fluctuates by ≥1.5°C or if 2 hours have elapsed since last calibration, ensuring consistent precision.
The EB82G-01MG-R-02 analytical and semi-micro balance delivers a dual-range weighing platform (82 g / 120 g) with 0.01 mg / 0.1 mg readability, internal automated calibration triggered by temperature drift ≥1.5°C or time lapse >2 h, and a split-body design to isolate vibration. A mandatory 30–60 min warm-up and controlled environment (10–33°C, 20–80% RH) are required for rated repeatability (±0.02 mg / ±0.1 mg).
Positive
- Split-body vibration isolation: The detached control display unit eliminates hand-induced micro-vibrations from the balance chassis, enabling stable real-time readings from flexible viewing angles.
- Autonomous internal calibration: The isbl integrated system automatically performs internal calibration when ambient temperature changes by ≥1.5°C or when 2 hours elapse, maintaining linearity without operator intervention.
Trade-offs
- Extended preheating requirement: A mandatory 30–60 minute warm-up after power-on is required before zeroing, calibration, or sample loading to ensure sensor stability and linearity.
- Controlled environment dependency: The balance must be operated within 10°C–33°C and 20%–80% RH; deviations outside these ranges can degrade repeatability and calibration accuracy.