ATOMFAIR® EB82G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB82G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB82G-01MG-R-02 Analytical & Semi-Micro Balance represents a classic rear-mounted electromagnetic force balancing platform integrated with high-sensitivity, premium stability sensors. Engineered with an ultra-rigorous, sophisticated chassis and an expanded spatial draft chamber, this dual-range system satisfies the most demanding laboratory requirements for ultra-precise mass determination, delivering baseline testing control and eliminating measurement drift.

EB82G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 82 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

This analytical balance requires a 30-60 minute warm-up after power-on to achieve thermal equilibrium and sensor stability. It must be operated within 10-33°C and 20-80% RH to maintain specified repeatability and linearity.

  • Warm-up Requirement: Allow the balance to warm up for 30-60 minutes following power-on before performing zeroing, calibration, or sample addition.
  • Environmental Stability: Operate the balance within 10-33°C ambient temperature and 20-80% RH to prevent measurement drift and maintain accuracy.
  • Automatic Calibration Trigger: The internal isbl calibration executes automatically when ambient temperature fluctuates by ≥1.5°C or when elapsed time exceeds 2 hours.
  • Vibration Isolation: Use the split-body architecture to isolate hand-induced micro-vibrations from the weighing chamber for stable readings.

Follow these steps to initialize and operate the balance for accurate mass determination. Proper warm-up and calibration are critical before sample measurement.

Required Equipment: Atomfair EB82G-01MG-R-02 Analytical Balance

  1. Power On and Warm-Up
    Power on the balance and allow 30-60 minutes for warm-up to stabilize the sensor.
  2. Perform Internal Calibration
    Initiate internal isbl calibration manually or allow the automatic trigger based on temperature or time.
  3. Zero the Balance
    Press the tare or zero key to reset the display before placing any sample.
  4. Add Sample and Record
    Place the sample on the pan and wait for the stabilization indicator before recording the mass.

What performance trade-off exists between the two readability ranges (0.01 mg and 0.1 mg) on the EB82G-01MG-R-02 balance, and how does capacity affect measurement precision?

The balance offers dual readability: 0.01 mg for semi-micro precision up to 82 g and 0.1 mg for analytical precision up to 120 g. Repeatability and linearity are ±0.02 mg in the finer range and ±0.1 mg in the coarser range, directly correlating readability with capacity. Users must choose higher capacity (120 g) with 0.1 mg readability or higher precision (0.01 mg) up to 82 g.

Can the EB82G-01MG-R-02 balance be integrated into automated data logging systems without additional hardware?

Yes, the balance includes an integrated RS232 communication bus that supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking. No additional interface hardware is required for serial communication.

What are the mandatory environmental and operational prerequisites for achieving rated precision on the EB82G-01MG-R-02 balance?

The balance requires a mandatory warm-up period of 30–60 minutes after power-on before zeroing or calibration. Operating temperature must be between 10°C and 33°C with 20%–80% relative humidity. The internal automated calibration (isbl) executes if ambient temperature fluctuates by ≥1.5°C or if 2 hours have elapsed since last calibration, ensuring consistent precision.

The EB82G-01MG-R-02 analytical and semi-micro balance delivers a dual-range weighing platform (82 g / 120 g) with 0.01 mg / 0.1 mg readability, internal automated calibration triggered by temperature drift ≥1.5°C or time lapse >2 h, and a split-body design to isolate vibration. A mandatory 30–60 min warm-up and controlled environment (10–33°C, 20–80% RH) are required for rated repeatability (±0.02 mg / ±0.1 mg).

Positive

  • Split-body vibration isolation: The detached control display unit eliminates hand-induced micro-vibrations from the balance chassis, enabling stable real-time readings from flexible viewing angles.
  • Autonomous internal calibration: The isbl integrated system automatically performs internal calibration when ambient temperature changes by ≥1.5°C or when 2 hours elapse, maintaining linearity without operator intervention.

Trade-offs

  • Extended preheating requirement: A mandatory 30–60 minute warm-up after power-on is required before zeroing, calibration, or sample loading to ensure sensor stability and linearity.
  • Controlled environment dependency: The balance must be operated within 10°C–33°C and 20%–80% RH; deviations outside these ranges can degrade repeatability and calibration accuracy.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).