ATOMFAIR® EB51G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB51G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB51G-01MG-R-02 Analytical & Semi-Micro Balance represents a classic rear-mounted electromagnetic force balancing platform integrated with high-sensitivity, premium stability sensors. Engineered with an ultra-rigorous, sophisticated chassis and an expanded spatial draft chamber, this dual-range system satisfies the most demanding laboratory requirements for ultra-precise mass determination, delivering baseline testing control and eliminating measurement drift.

EB51G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 51 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

The balance requires a 30–60 minute warm-up period after power-on before any weighing or calibration operations. The operating environment must be maintained at 10–33°C and 20–80% RH to ensure measurement accuracy.

  • Warm-Up Requirement: The balance must be powered on and allowed to stabilize for 30–60 minutes before use.
  • Environmental Conditions: The balance should be operated in a temperature range of 10–33°C and humidity of 20–80% RH.
  • Automatic Calibration Trigger: Internal automated calibration is executed when ambient temperature changes by ≥1.5°C or after 2 hours of operation.
  • Vibration Isolation: The split-body design isolates the weighing cell from hand-induced vibrations to maintain stable readings.
  • Draft Shield Protection: The transparent draft shield protects the weighing chamber from air currents and contaminants.

The balance must be warmed up for 30–60 minutes before use. Calibration should be performed after warm-up and periodically during operation.

Required Equipment: Atomfair EB51G-01MG-R-02 Analytical Balance

  1. Power On
    Power on the balance using the supplied power adapter.
  2. Warm-Up
    Allow the balance to warm up for 30 to 60 minutes before proceeding.
  3. Zero the Balance
    Perform a zeroing operation by pressing the tare button.
  4. Calibrate
    Initiate internal calibration using the automatic or manual calibration function.
  5. Weigh Sample
    Place the sample on the weighing pan and record the stable measurement.

How does the dual-range readability of 0.01 mg and 0.1 mg affect measurement repeatability across the two capacity ranges on the EB51G-01MG-R-02 balance?

The balance provides automated dual-range switching between 0.01 mg readability (max capacity 51 g) and 0.1 mg readability (max capacity 120 g). At the higher precision range, standard repeatability deviation is ±0.02 mg; at the lower precision range, it is ±0.1 mg. This trade-off allows ultra-precise measurements for small samples while extending capacity for larger samples with proportionally relaxed repeatability.

What environmental conditions are required to maintain the EB51G-01MG-R-02's internal calibration accuracy?

The internal isbl calibration system automatically activates if ambient temperature fluctuates by ≥1.5°C or if more than 2 hours have elapsed since last calibration. The operating environment must be maintained at 10°C–33°C and 20%–80% RH to ensure stable readings and prevent drift, as specified in the environmental constraints.

Why is a 30–60 minute warm-up period mandatory before using the EB51G-01MG-R-02 balance for critical measurements?

The balance requires a mandatory preheating threshold of 30–60 minutes following power-on to stabilize the rear-mounted electromagnetic force sensor and eliminate baseline drift. Operating without this warm-up can compromise reading precision and sensor linearity, as stated in the operational notice.

The EB51G-01MG-R-02 dual-range analytical balance delivers 0.01 mg readability up to 51 g and 0.1 mg up to 120 g, with internal automated calibration triggered by temperature shifts ≥1.5°C or 2-hour intervals, but requires a 30–60 minute warm-up and stable environmental conditions (10–33°C, 20–80% RH) to maintain specified repeatability of ±0.02 mg.

Positive

  • Dual-range readability with internal calibration: Automated dual-range readability (0.01 mg / 0.1 mg) combined with internal isbl calibration that activates upon ≥1.5°C ambient temperature drift or 2-hour elapsed time ensures sustained metrological traceability without manual intervention.
  • Split-body design reduces vibration interference: Detached control display unit isolates hand-induced micro-vibrations from the balance base, enabling stable readings and flexible viewing angles during precision weighing operations.

Trade-offs

  • Mandatory 30–60 minute warm-up period: The balance requires a 30–60 minute preheating threshold after power-on before operational zeroing or calibration can be performed, delaying immediate use in time-sensitive workflows.
  • Sensitive to ambient temperature and humidity: Specified operating range of 10°C–33°C and 20%–80% RH imposes strict environmental control requirements; deviations may compromise repeatability (±0.02 mg) and linearity (±0.02 mg) specifications.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).