ATOMFAIR® EB51G-01MG-R-01 ANALYTICAL & SEMI-MICRO BALANCEEB51G-01MG-R-01 CORE SPECIFICATION PLATFORM
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This balance requires a 30-60 minute warm-up period after power-on before zeroing or calibration to ensure sensor stability. Operation is restricted to an ambient temperature range of 10°C to 33°C and humidity between 20% and 80% RH to maintain measurement accuracy.
- Warm-up Requirement: Allow the balance to stabilize for 30 to 60 minutes following power-on before performing any measurement operations.
- Temperature Range: Operate the balance only within an ambient temperature of 10°C to 33°C to avoid measurement drift.
- Humidity Range: Maintain relative humidity between 20% and 80% in the operating environment to prevent condensation or static interference.
- Calibration Trigger Conditions: The balance automatically initiates internal calibration when the ambient temperature changes by 1.5°C or more, or after 2 hours of idle time.
- Power Supply Infrastructure: Connect the balance to a 220V AC / 50Hz mains supply delivering 12V DC / 2A output for proper operation.
Follow this procedure to prepare the balance for accurate weighing after initial power-up. Adherence to warm-up and calibration steps ensures repeatable results within specified tolerances.
- Power On
Press the power button to switch on the balance and allow the display to initialize. - Warm-up Period
Allow the balance to stabilize for 30 to 60 minutes without any sample on the pan. - Perform Zeroing
Press the tare or zero key to reset the display to zero with no load on the pan. - Initiate Calibration
Trigger internal calibration either automatically by a temperature change or manually using the calibration button to ensure accuracy.
How does the dual-range readability of 0.01 mg / 0.1 mg affect measurement repeatability across the 51 g and 120 g capacity thresholds?
The EB51G-01MG-R-01 delivers a standard repeatability deviation of ±0.02 mg at the 0.01 mg readability range (up to 51 g) and ±0.1 mg at the 0.1 mg readability range (up to 120 g). This dual-range matrix allows researchers to optimize precision for sub-51 g samples while retaining the ability to weigh heavier specimens up to 120 g with acceptable repeatability, all within a single platform.
Can the EB51G-01MG-R-01 be integrated with existing laboratory data systems via its RS232 port, and what are the compatibility constraints?
Yes, the balance includes an integrated RS232 communication bus that supports bidirectional data pipelines to micro-printers and host computer terminals for automated data logging and paperless compliance tracking. No additional protocol details are provided in the source, so integration with proprietary LIMS or legacy systems may require custom cabling or adapter verification; the port is standard RS232, not USB or Ethernet.
What are the mandatory preheating and environmental requirements to ensure stable operation and avoid calibration drift?
The balance requires a mandatory preheating threshold of 30 to 60 minutes following power-on initialization before performing zeroing, internal calibration, or sample addition. Operating environment must be maintained at 10°C to 33°C with relative humidity between 20% and 80% RH. The internal automated calibration (isbl) triggers automatically if ambient temperature fluctuates by ≥1.5°C or if more than 2 hours have elapsed since last calibration.
The EB51G-01MG-R-01 dual-range analytical balance delivers 0.01 mg readability up to 51 g and 0.1 mg up to 120 g, with internal automated calibration triggered by temperature shifts ≥1.5°C or 2-hour intervals, but requires a 30–60 minute warm-up before use and operates within a narrow 10°C–33°C temperature window.
Positive
- Dual-range high-resolution weighing: Automated switching between 0.01 mg readability at 51 g capacity and 0.1 mg at 120 g capacity enables both semi-micro and analytical mass determinations on a single platform, reducing instrument redundancy.
- Autonomous internal calibration system: The isbl integrated calibration automatically re-zeroes the sensor when ambient temperature fluctuates by ≥1.5°C or after 2 hours of operation, maintaining metrological traceability without operator intervention.
Trade-offs
- Mandatory preheating before use: A 30–60 minute warm-up period is required after power-on to stabilize the electromagnetic force sensor and eliminate thermal drift, delaying immediate measurement readiness.
- Narrow operating temperature range: The balance is specified for 10°C–33°C ambient conditions; deviations outside this window may compromise repeatability and linearity, necessitating climate-controlled laboratory environments.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).