Description
ATOMFAIR® EB320G-0.1MG-02 HIGH-PRECISION ANALYTICAL BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This precision balance requires a level, vibration-free stone table and a pre-warming period before operation. The integrated transport lock must be engaged whenever the device is moved to prevent damage to the glass door mechanism.
- Leveling requirement: The balance must be placed on a stable anti-vibration stone table and leveled using the adjustable feet until the bubble level is centered.
- Pre-warming requirement: The balance must be powered on and allowed to stabilize according to manufacturer specifications before any measurements are taken.
- Transport lock mechanism: The mechanical glass door transport lock must be activated before moving the balance to secure the draft shield and prevent damage.
- Anti-vibration foundation: The full-aluminum base and anti-shock adaptation settings should be configured to match the laboratory's vibration profile.
- Draft shield usage: The four-sided transparent glass draft shield and under-pan breeze shield must be in place during operation to eliminate air current interference.
Follow these steps to correctly install and prepare the balance for high-precision weighing. Proper setup ensures repeatable 0.1 mg accuracy and protects the instrument from damage.
Required Equipment: Anti-vibration stone table, Leveling bubble indicator, Glass draft shield, Transport lock
- Place on stable table
Place the balance on a dedicated anti-vibration stone table in a draft-free area. - Level the balance
Level the balance by adjusting the four feet until the bubble level is centered within the indicator. - Pre-warm the instrument
Pre-warm the balance by connecting to power and allowing at least 30 minutes of stabilization before calibration. - Activate transport lock
Activate the glass door transport lock to secure the draft shield before any movement of the device. - Close draft shield
Close all glass draft shield panels and ensure the under-pan breeze shield is in place to minimize air currents. - Perform calibration
Perform a zero-tracking calibration using the built-in automatic function to verify accuracy. - Start weighing
Place the sample on the pan and allow the reading to stabilize before recording the mass.
Does the ±0.2 mg linearity error of the EB320G-0.1MG-02 limit its use for sub-milligram material characterization?
Yes, the ±0.2 mg linearity error means that measurements across the full 320 g range may deviate by up to 0.2 mg, which is twice the 0.1 mg readability. This is acceptable for trace quantitative chemistry analysis and micro-sample auditing as stated in the application scope, but researchers must account for this nonlinearity when verifying ultra-low mass differences near the readability limit.
Can the EB320G-0.1MG-02 analytical balance be used for piece counting of small parts in quality control workflows?
Yes, the balance features dual-mode piece counting, which allows counting of small parts based on reference weight. This is supported by the 0.1 mg readability and 320 g capacity, making it suitable for micro-components weighing under 320 g in quality control or inventory applications.
What type of laboratory table is required for the EB320G-0.1MG-02 to achieve its 0.1 mg repeatability specification?
The balance must be completely leveled on an anti-vibration stone table, as explicitly stated in the important notice. This is essential to isolate the 4-level anti-shock adaptation and full-aluminum base foundation from low-frequency vibrations, ensuring the ±0.1 mg repeatability is achieved reliably.
The ATOMFAIR EB320G-0.1MG-02 analytical balance delivers 0.1 mg readability with robust vibration isolation and draft shielding, but requires strict pre-operational leveling and warm-up, plus mandatory transport lock engagement, making it suitable for dedicated precision metrology stations.
Positive
- Vibration suppression architecture: Full aluminum base foundation with 4-level anti-shock adaptation actively cancels ambient low-frequency vibrations, enabling reliable 0.1 mg readability without external isolation tables.
- Integrated draft shield system: Four-sided transparent glass draft shield with aluminum backplate and under-pan breeze shield fully isolates the analytical chamber from cross-currents, critical for sub-milligram gravimetric stability.
Trade-offs
- Mandatory anti-vibration table and warm-up: The balance must be leveled on an anti-vibration stone table and pre-warmed to specification before operation; inadequate preparation degrades 0.1 mg accuracy.
- Transport lock required before movement: The mechanical glass door transport lock must be engaged prior to relocation; moving the device without locking risks damage to the precision mechanism and alignment.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.