Description
ATOMFAIR® EB320G-1MG-D ELECTRONIC DENSITY ANALYTICAL BALANCEDENSITY METRIC DIVISION
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires the sample to have an air weight ≥ 0.25 g and a buoyant lift ≤ -0.125 g to maintain measurement integrity. Density measurement precision is tied to the balance's readability and repeatability, necessitating proper calibration before use.
- Sample Weight Constraint: The measured sample must have an air weight of at least 0.25 g and its buoyant lift in liquid must not exceed -0.125 g to avoid mathematical scaling errors.
- Calibration Dependency: The precision and decimal places of density measurements are strictly paired with the baseline readability metrics of the balance frame, requiring calibration to match the balance's resolution.
- Environmental Protection: The integrated display protective shield must be used to guard the screen against laboratory dust, debris, and scratches that could obstruct readings.
- Measurement Compatibility: The balance is validated for density calculations of polymers, alloys, glass compounds, fluids, and metallurgy products, but other materials may require verification.
How does the 1 mg readability of the EB320G-1MG-D balance affect the achievable density measurement precision for solids and liquids?
The density measurement precision (g/cm³) for the EB320G-1MG-D is strictly paired with its 1 mg readability, meaning the decimal places of the density result are consistent with the balance resolution. However, the minimum sample weight in air must be ≥ 0.25 g, and its buoyant lift in the liquid ≤ -0.125 g. For samples at these boundaries, the 1 mg readability may limit the density resolution compared to higher-readability models, but the balance is designed for reliable direct-reading density evaluation across its specified mass range.
What sample mass and material constraints apply when using the EB320G-1MG-D for density testing?
Solids and liquids are supported, with a standard stainless steel reference plummet included for liquid immersion validation. For solids, the weight in air must be ≥ 0.25 g, and the total buoyant force in the liquid must not exceed -0.125 g. Compatible materials include polymers, alloy complexes, technical glass compounds, fluid dynamics, and structured metallurgy products.
What operational safeguards and boundaries must be observed to maintain measurement accuracy with the EB320G-1MG-D balance?
The balance is factory-fitted with an integrated display protective shield that guards against laboratory dust, debris, and scratches. To preserve matrix integrity and prevent mathematical scaling drops, ensure the sample weight in air is ≥ 0.25 g and its buoyancy in the liquid is ≤ -0.125 g. The density precision is directly tied to the 1 mg readability of the balance, so consistent environmental conditions are recommended for reliable results.
The EB320G-1MG-D integrates a 320g capacity, 1mg readability balance with an Archimedes density kit for solid and liquid density measurements, but requires samples with air weight ≥0.25g and buoyancy ≤-0.125g, and its density precision is limited by the 1mg readability.
Positive
- Synchronized High-Precision Output: The analytical balance base and density kit operate in perfect harmony, ensuring density results (g/cm³) maintain exact decimal consistency with the balance resolution (1 mg), eliminating drift.
- Archimedes Displacement Integration: Leverages advanced hydro-displacement principles for direct-reading solid and liquid density evaluations, providing prompt, error-free data outputs without mathematical drift.
Trade-offs
- Minimum Sample Weight Constraint: To preserve matrix integrity, the measured sample must have an air weight ≥ 0.25 g and a total buoyant lift in liquid ≤ -0.125 g, limiting applicability for very small or low-density samples.
- Density Precision Tied to Balance Readability: The precision and effective decimal places of density measurements are strictly paired with the baseline readability of the integrated balance (1 mg), capping density resolution at approximately ±0.001 g/cm³.