Analytical Semi-Micro Balance 31/120g 0.01mg ATOMFAIR®

$1,058.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Dual-range analytical semi-micro balance with internal isbl calibration, 0.01/0.1 mg readability, 31/120 g capacity, ≤5 s stabilization. Order now.

SKU: AF-EI-B-SMBL-120U-IR04
Category: ,

Description

ATOMFAIR® EB31G-01MG-R-02 ANALYTICAL & SEMI-MICRO BALANCE

EB31G-01MG-R-02 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB31G-01MG-R-02 Analytical & Semi-Micro Balance represents a classic rear-mounted electromagnetic force balancing platform integrated with high-sensitivity, premium stability sensors. Engineered with an ultra-rigorous, sophisticated chassis and an expanded spatial draft chamber, this dual-range system satisfies the most demanding laboratory requirements for ultra-precise mass determination, delivering baseline testing control and eliminating measurement drift.

EB31G-01MG-R-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Calibration Configuration Internal Automated Calibration Variant (isbl Integrated System)
Readability Division Value 0.01 mg / 0.1 mg (Automated Dual Range Matrix)
Maximum Scale Capacity 31 g / 120 g (Dual-Range Fluctuating)
Standard Repeatability Deviation ±0.02 mg / ±0.1 mg
Linearity Distortion Error ±0.02 mg / ±0.1 mg
Average Stabilization Response Time ≤ 5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 90 mm
Outer Structural Dimensions 410 mm × 310 mm × 320 mm
Effective Draft Shield Height 230 mm
Internal Weighing Chamber Size 195 mm × 100 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 10°C ~ 33°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

ES Series Comprehensive Portfolio Comparison Matrix

SPECIFICATION ITEM EB31G-01MG-R-01 EB51G-01MG-R-01 EB82G-01MG-R-01 EB31G-01MG-R-02 EB51G-01MG-R-02 EB82G-01MG-R-02 EB82G-01MG-R-02
Readability Value (mg) 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1 0.01/0.1
Max Capacity Threshold (g) 31/120 51/120 82/120 31/120 51/120 82/120 120
Repeatability Dev. (mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Linearity Error Max (±mg) ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1 ±0.02/0.1
Stabilization Target (s) ≤ 5 Seconds (All Models Equipped)
Warm-up Duration Threshold 30 ~ 60 Minutes Required
Weighing Pan / Chassis Pan: Φ 90 mm | Outer Matrix: 410 × 310 × 320 mm | Shield Height: 230 mm | Chamber Size: 195 × 100 mm
Environment Requirements Temp Threshold: 10°C ~ 33°C | Humidity Workspace Range: 20% ~ 80% RH
Power Subsystem Profiles Global Matrix Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A (All Models Shared)

Full Series Core Functional Advantages

  • Split-Body Structural Architecture: Detached control display unit isolates hand-induced micro-vibrations from the balance baseline chassis, allowing real-time data inspection from multiple flexible angles.
  • Transparent Panoramic Glass Draft Shield: Provides all-around panoramic visibility of weighing specimens with quick-release mechanics for rapid disassembly and efficient decontamination.
  • Rear-Mounted Electromagnetic Force Sensor: Premium-tier high-accuracy internal balance core ensures outstanding repeatability, stable readings, and fast response kinetics.
  • Extendable & Adjusting LED Display Panel: Features an ultra-bright layout that allows operators to seamlessly adjust the display tilt angle for zero-parallax reading verification.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard foundational weight measurement, percentage balance determination, and precise parts tracking/piece counting workflows.
  • Instantaneous Multi-Unit Conversions: Enables single-key toggle transitions between international mass dimensions including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math.
  • Optimized Trace Micro-Addition Processing: Driven by advanced digital signal processing firmware, the system maintains rock-solid readouts with zero baseline drift, micro-capturing minute sample additions with high fidelity.
  • Integrated RS232 Communication Bus: Bidirectional port supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking.
  • Autonomous Fully Automatic isbl Calibration: Executes automated internal balancing calibration if ambient workspace temperature fluctuates by ≥1.5°C or if time elapsed exceeds 2 hours. Supports manual override.

APPLICATION SCOPE: High-accuracy industrial laboratory analysis, analytical chemistry, premium material research, and dual-range core verification workflows.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised reading precision and maintain sensor linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, internal calibration, or sample addition.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

This balance requires a 30–60 minute warm-up period after power-on before calibration or use to ensure sensor linearity. Operation is restricted to 10°C–33°C and 20%–80% RH to maintain specified repeatability and linearity tolerances.

  • Warm-Up Requirement: Allow 30–60 minutes of uninterrupted power-on time before performing zeroing, calibration, or sample measurements.
  • Environmental Stability: Maintain ambient temperature within 10°C–33°C and relative humidity between 20% and 80% to prevent drift and ensure ±0.02 mg repeatability.
  • Automatic Calibration Trigger: The internal isbl calibration system activates automatically when ambient temperature shifts by ≥1.5°C or when 2 hours have elapsed since last calibration.

This procedure ensures the balance reaches thermal equilibrium and performs an internal calibration before use. Following these steps prevents measurement drift and maintains dual-range accuracy.

Required Equipment: Atomfair EB31G-01MG-R-02 Analytical Balance, Stable, vibration-free laboratory bench

  1. Power On and Warm Up
    Connect the balance to the 220V AC / 50Hz power supply and switch on the unit, then allow 30–60 minutes for the internal sensor to stabilize.
  2. Verify Environmental Conditions
    Confirm the ambient temperature is between 10°C and 33°C and relative humidity is between 20% and 80% using a calibrated thermometer and hygrometer.
  3. Initiate Internal Calibration
    Press the calibration key to trigger the isbl automated internal calibration, or wait for the system to auto-calibrate if a ≥1.5°C temperature shift or 2-hour interval has elapsed.
  4. Confirm Calibration Completion
    Verify that the display shows a stable zero reading and that the calibration indicator confirms successful completion before proceeding to sample measurement.
  5. Select Weighing Range and Mode
    Choose the desired dual-range readability (0.01 mg or 0.1 mg) and operational mode (standard, percentage, or parts counting) using the front panel controls.
  6. Place Sample and Record Mass
    Gently place the sample on the Φ 90 mm pan within the draft shield, close the glass doors, and wait for the stabilization indicator before recording the reading.

How does the dual-range readability of 0.01 mg and 0.1 mg affect measurement accuracy at the maximum capacities of 31 g and 120 g on the EB31G-01MG-R-02?

The balance automatically toggles between two ranges: at 0.01 mg readability up to 31 g, repeatability is ±0.02 mg; at 0.1 mg readability up to 120 g, repeatability is ±0.1 mg. This trade-off delivers sub-milligram precision for small samples while maintaining analytical-grade accuracy for larger masses, all within a single instrument.

What external data systems can the EB31G-01MG-R-02 integrate with for automated data logging?

The balance includes an integrated RS232 communication bus that supports direct data pipelines to micro-printers and host computer terminals, enabling automated data logging and paperless compliance tracking. It does not specify USB or Ethernet interfaces, so integration with modern LIMS or PC networks may require an RS232-to-USB adapter or serial converter.

What are the mandatory warm-up and environmental requirements to ensure accurate operation of the EB31G-01MG-R-02?

The balance requires a 30–60 minute warm-up after power-on before performing zeroing, internal calibration, or sample addition. Operating environment must be within 10°C–33°C and 20%–80% RH. The internal isbl calibration automatically triggers if temperature fluctuates by ≥1.5°C or if 2 hours have elapsed, ensuring drift compensation.

The EB31G-01MG-R-02 offers dual-range readability of 0.01 mg/0.1 mg with capacities of 31 g/120 g, supported by internal automated calibration (isbl) triggered by temperature or time changes. However, it requires a 30–60 minute warm-up and operates within strict environmental limits of 10–33°C and 20–80% RH.

Positive

  • Dual-Range Readability and Capacity: Provides 0.01 mg readability for semi-micro work and 0.1 mg for analytical work, with corresponding capacities of 31 g and 120 g, enabling versatile mass determination on a single platform.
  • Internal Automated Calibration (isbl): The balance automatically recalibrates when ambient temperature shifts by ≥1.5°C or after two hours, maintaining measurement accuracy without operator intervention.

Trade-offs

  • Mandatory Preheating Period: A warm-up of 30 to 60 minutes is required after power-on before the balance can deliver stable, accurate readings, delaying immediate use.
  • Controlled Environmental Requirements: Optimal performance is confined to 10–33°C and 20–80% RH; deviations may compromise repeatability and linearity.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).