Description
ATOMFAIR® EB210G-0.1MG-R-02 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCERESEARCH GRADE
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This instrument requires a 30-minute pre-heating period and a sealed three-door draft shield to achieve hundred-thousandth resolution accuracy. Environmental temperature stability and proper leveling via the built-in spirit level and adjustable feet are critical to prevent drift and maintain measurement fidelity.
- Thermal Equilibrium Requirement: Allow the electromagnetic force compensation core to warm up for 30 minutes before any calibration or high-resolution weighing.
- Draft Shield Sealing: Ensure the three-door glass draft shield is fully closed and sealed when operating in the 0.01 mg readability mode.
- Leveling Procedure: Verify the front bubble spirit level is centered by adjusting the heavy-duty micro-threaded leveling feet prior to use.
Follow these steps to stabilize and prepare the balance for high-resolution weighing. Each action ensures the electromagnetic core and environmental enclosure are at their operational set points.
Required Equipment: Spirit level indicator, Micro-threaded leveling feet, Three-door draft shield
- Level the balance
Level the balance by adjusting the heavy-duty micro-threaded feet until the front bubble spirit level is centered. - Pre-heat the core
Allow the electromagnetic force compensation system to pre-heat for 30 minutes to reach full equilibrium. - Seal the draft shield
Confirm the three-door glass draft shield is entirely sealed before initiating measurements at hundred-thousandth resolution.
What is the practical accuracy trade-off when using the dual-range EB210G-0.1MG-R-02 balance at 0.01 mg readability versus 0.1 mg readability?
The balance delivers 0.01 mg readability only up to 82 g capacity, with repeatability and linearity of ±0.06 mg, while the 0.1 mg mode extends to 210 g with ±0.6 mg. Achieving the higher resolution requires a 30-minute pre-heating phase and a fully sealed three-door draft shield to neutralize ambient drift, as specified in the operational notice.
Can the EB210G-0.1MG-R-02 balance be integrated with automated data logging or external density measurement systems?
Yes, it includes a standard RS232 digital output interface for direct computer logging or peripheral printer output. Additionally, the balance supports under-hook density configurations for bottom-weighing accessories and hydrostatic test stands, enabling dual-purpose gravimetric measurements.
What environmental and operational conditions are required to maintain 0.01 mg accuracy on the EB210G-0.1MG-R-02?
The draft shield must be fully sealed during hundred-thousandth weighing routines. A 30-minute system pre-heating phase is mandatory to allow the electromagnetic core to reach equilibrium. The balance is equipped with a front-mounted bubble spirit level and heavy-duty micro-threaded leveling feet, and the FA variant features automated internal calibration triggered by time or ambient temperature fluctuations to compensate for drift.
The EB210G-0.1MG-R-02 dual-range analytical balance uses rear-mounted EMFC for high-stability weighing, offering 210 g capacity at 0.1 mg and 82 g at 0.01 mg, but requires careful environmental conditioning and a pre-heating period for semi-micro precision.
Positive
- Rear-Mounted EMFC Sensor Technology: High-sensitivity electromagnetic force compensation maximizes resolution stability for precise analytical weighing.
- Dual-Resolution Mode Flexibility: Switching between 0.1 mg and 0.01 mg readability allows adaptation to varying precision needs within a single instrument.
Trade-offs
- Restricted High-Resolution Capacity: At 0.01 mg readability, maximum capacity drops to 82 g, limiting semi-micro weighing to lighter samples.
- Required Pre-Heating and Draft Shield Sealing: For 0.01 mg operation, a 30-minute warm-up and complete closure of the three-door draft shield are mandatory to achieve equilibrium.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.