Electronic Analytical Balance EB210G 220g 0.1mg ATOMFAIR®

$1,029.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

EB210G-0.1MG-I analytical balance with 220g capacity, 0.1mg readability, ±0.1mg repeatability, auto-calibration, RS232, and Φ80mm pan. Order now.

SKU: AF-EI-B-ANLB-220A-IR05
Category: ,

Description

ATOMFAIR® EB210G-0.1MG-I ELECTRONIC ANALYTICAL BALANCE

RESEARCH GRADE METROLOGY

Product Overview

The ATOMFAIR® EB210G-0.1MG-I sets the industry benchmark for laboratory cell-to-cell consistency and baseline testing control. Engineered with a classic rear-mounted electromagnetic force restoration sensor, this series eliminates measurement variables during rigorous sample processing. Its distinctive split-type architecture decouples the high-brightness LED display unit from the weighting block, mitigating operational kinetic vibrations to ensure pure validation platform benefits. Optimized for ultra-low mass powder and fluid tracking up to 220g, it remains a premier infrastructure choice for premium analytical labs exploring high precision laboratory scale price options.

EB210G-0.1MG-I Detailed Metrology Parameters

PARAMETER ITEM TECHNICAL SPECIFICATION DETAILS
Product Model EB210G-0.1MG-I
Product Classification Electronic Analytical Balance
Readability (d) 0.1mg
Maximum Capacity (Max) 220g
Repeatability Error ±0.1mg
Linearity Error ±0.2mg
Average Stabilization Time ≤2.5s
Initial Warm-up Duration 30~60min
Weighing Pan Dimensions Φ80mm
Draftshield Internal Width 230mm
Overall Physical Dimensions 470 × 310 × 330mm
Operating Ambient Temp 18°C~23°C
Operating Ambient Humidity 20%~80%RH
Power Supply Specifications Input: 220VAC 50Hz, Output: 12V/2A

Semi-Micro Analytical Balance Comprehensive Matrix

MODEL / PARAMETER EB31-120G-01MG-R EB51-120G-01MG-R EB82-120G-01MG-R EB31-210G-01MG-R EB51-210G-01MG-R EB82G-01MG-R-03 EB120-120G-01MG-R
Readability (d) 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg
Max Capacity (Max) 31/120g 51/120g 82/120g 31/210g 51/210g 82/210g 120g
Repeatability Error ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg
Linearity Error ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg
Calibration Weight 10g 10g 10g 10g 10g 10g 10g
Stabilization Time ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s
Preheat Duration 30~60m 30~60m 30~60m 30~60m 30~60m 30~60m 30~60m
Pan Size / Draftshield Φ80mm Stainless Steel Pan / 230mm Internal Chamber Safety Width
Dimensions / Environment 470 × 310 × 330mm Form Factor / 18°C~23°C Thermal Zone / 20%~80%RH Matrix
Power Parameters Unified Architecture: 220VAC 50Hz Stable Input, 12V/2A Pure DC Output

Electronic Analytical Balance Comprehensive Matrix

MODEL / PARAMETER EB120G-0.1MG-02 EB210G-0.1MG-01 EB220G-0.1MG-02 EB320G-0.1MG-01 EB120G-0.1MG-I-01 EB210G-0.1MG-I ES-E320A
Readability (d) 0.1mg Across Entire Configuration Family
Max Capacity (Max) 120g 210g 220g 120g 210g 220g 320g
Repeatability Error ±0.1mg Controlled Tolerance Threshold
Linearity Error ±0.2mg Linearity Correction Limit
Stabilization Time ≤2.5 seconds (Average Kinetic Interval)
Preheat Duration 30~60 minutes Baseline Core Setup
Hardware Form Factor Φ80mm Pan / 230mm Internal Chamber Width / 470 × 310 × 330mm Total Enclosure
Operating Conditions 18°C~23°C Regulated Temperature / 20%~80%RH / Input 220VAC, Output 12V/2A

General Matrix Specifications

GENERAL ATTRIBUTE STANDARD CONFIGURATION VALUES
Stabilization Time ≤2.5s (Average Operational Interval)
Initial Warm-up Duration 30~60min for Core Metrology Stabilization
Weighing Pan Dimension Φ80mm Stainless Steel Architectural Platform
Draftshield Chamber Width 230mm Anti-static Internal Space
Overall Form Factor 470 × 310 × 330mm Total Spatial Dimensions
Operating Ambient Temp 18°C~23°C Regulated Thermal Zone
Operating Ambient Humidity 20%~80%RH Non-condensing Atmospheric Matrix
Power Module Configuration Input: 220VAC 50Hz, Output: 12V/2A Stable DC Link

Key Features & Advantages

  • Rear-Mounted Electromagnetic Restoration: High precision and premium resolution architecture providing ultra-responsive, rapid, and drift-free mass detection kinetics.
  • Vibration-Isolated Split Design: Intelligently decouples the extensible high-definition LED panel from the core weighing mechanism, completely eliminating keystroke kinetic interference.
  • All-Around Structural Glass Shield: Seamless transparent protection block ensuring robust sample integrity, designed for tool-less removal and efficient sanitization cycles.
  • Advanced Intelligent Auto-Calibration: Fully automated alignment tracking loop triggered instantly upon thermal fluctuations >1.5°C or every 2 hours to eliminate ambient errors.
  • Multi-Mode Unit Transformation: Comprehensive onboard software supporting g, ct, oz, lb calculations paired with micro-addition scaling optimized for powder or liquid processing.
  • Bidirectional Data Synchronicity: Equipped with industrial RS232 communication interfaces for seamless integration with peripherals, PCs, and third-party LIMS environments.

APPLICATION SCOPE: High precision laboratory metrology, micro-powder tracking, fluid fraction control, and multi-unit scientific validation.
PACKAGING: Industrial shockproof high-density foam framing with isolated glass panels and customized power modular blocks.
IMPORTANT NOTICE: To secure uncompromised 0.1mg/0.01mg metrology performance, power up and allow the system to calibrate internally within the 18°C~23°C thermal zone for 30~60 minutes before verification.
TAILORED METROLOGY FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The balance requires a regulated thermal environment of 18–23°C and non-condensing humidity of 20–80%RH to maintain metrology stability. A 30–60 minute warm-up period is mandatory before use to achieve core stabilization and eliminate drift.

  • Thermal and Humidity Requirements: Operating ambient temperature must be maintained at 18–23°C with relative humidity between 20% and 80% non-condensing to prevent measurement errors.
  • Warm-Up Protocol: Initial warm-up duration of 30–60 minutes is required for the electromagnetic force restoration sensor to stabilize before any verification or measurement.
  • Auto-Calibration Trigger: The intelligent auto-calibration loop activates automatically when ambient temperature fluctuates more than 1.5°C or every 2 hours to correct for thermal drift.
  • Vibration Isolation: The split architecture decouples the display from the weighing block to eliminate keystroke kinetic interference, requiring placement on a stable, vibration-free surface.
  • Draftshield Integrity: The all-around glass shield must be properly seated during operation to protect against air currents and contamination, and is removable for cleaning without tools.

Proper initialization and operation require a stable environment, adequate warm-up, and calibration verification. Follow these steps to ensure accurate metrology performance.

Required Equipment: Stable laboratory bench (vibration-free), Power supply unit (220VAC 50Hz input, 12V/2A output), Internal calibration mechanism or certified standard weight

  1. Position the Balance
    Place the balance on a stable, vibration-free surface within the 18–23°C thermal zone and 20–80%RH non-condensing atmosphere.
  2. Connect Power and Warm Up
    Connect the power supply and allow the instrument to warm up and self-calibrate for 30–60 minutes before any verification.
  3. Verify Calibration
    After warm-up, verify accuracy by triggering the internal calibration function or using a certified standard weight.
  4. Monitor Auto-Calibration
    Ensure the auto-calibration feature is enabled to automatically correct for temperature fluctuations exceeding 1.5°C or every 2 hours.
  5. Clean the Draftshield
    Remove the glass draftshield for sanitization cycles as needed, then reattach it securely before resuming measurements.

How does the intelligent auto-calibration feature on the ATOMFAIR EB210G-0.1MG-I trade off between thermal stability and continuous measurement throughput?

The auto-calibration triggers upon a temperature fluctuation greater than 1.5°C or every 2 hours, automatically correcting for ambient drift but temporarily interrupting the measurement workflow. This trade-off prioritizes sustained accuracy over uninterrupted throughput, making the balance ideal for research-grade metrology where precision is critical and calibration cycles can be scheduled around experiments.

What are the integration constraints when connecting the EB210G-0.1MG-I to a third-party LIMS via its RS232 interface?

The balance is equipped with an industrial RS232 interface for bidirectional data synchronicity with PCs, peripherals, and third-party LIMS environments, as stated in the product specifications. However, the provided description does not include protocol details such as baud rate, parity, or cable pinout, so users must consult ATOMFAIR engineering support for full configuration parameters. The split architecture additionally requires the weighing block to remain on a stable, vibration-free surface within the 18–23°C thermal zone to ensure data integrity.

What are the critical infrastructure requirements for deploying the EB210G-0.1MG-I to maintain its 0.1mg accuracy?

The balance requires a stable power supply of 220VAC 50Hz input with a 12V/2A DC output, an operating ambient temperature of 18–23°C, and humidity between 20% and 80% RH non-condensing. A mandatory 30–60 minute warm-up period is necessary for core metrology stabilization before any verification, and the draftshield must be placed in a vibration-isolated environment to prevent kinetic interference from keystrokes on the decoupled LED display.

The EB210G-0.1MG-I offers 0.1 mg readability and 220 g capacity with an electromagnetic force restoration sensor and split-design architecture to minimize vibration interference. Its auto-calibration compensates for thermal drift, but requires a 30-60 minute warm-up and a controlled 18–23°C environment for rated accuracy.

Positive

  • Rear-mounted electromagnetic restoration sensor: Provides ultra-responsive, rapid, and drift-free mass detection kinetics with 0.1 mg readability and ±0.1 mg repeatability, suitable for high-precision laboratory metrology.
  • Vibration-isolated split architecture: Decouples the LED display from the weighing block, eliminating keystroke kinetic interference and maintaining measurement integrity during sample processing.

Trade-offs

  • Extended warm-up requirement: Requires 30–60 minutes of power-on stabilization within the specified thermal zone before achieving rated 0.1 mg metrology performance.
  • Narrow ambient temperature window: Operating temperature must be strictly maintained between 18°C and 23°C; deviations outside this range may affect measurement accuracy and require recalibration.