Description
ATOMFAIR® EB210G-0.1MG-D DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCESEMI-MICRO PRECISION
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires a 30-minute pre-heating phase for the electromagnetic core to reach thermal equilibrium before calibration. The draft shield must be fully sealed during 0.01 mg semi-micro weighing to prevent ambient air currents from affecting readings.
- Thermal Stabilization Requirement: Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
- Draft Shield Sealing Requirement: For hundred-thousandth semi-micro weighing verification routines (0.01 mg), ensure the three-door draft shield housing is entirely sealed.
This procedure covers the pre-heating and calibration steps required before performing 0.01 mg resolution measurements. Proper environmental sealing and thermal stabilization are critical for achieving specified repeatability.
Required Equipment: EB210G-0.1MG-D Dual-Range Electromagnetic Analytical Balance
- Power On and Pre-Heat
Power on the balance and allow a 30-minute pre-heating phase for the electromagnetic core to reach full thermal equilibrium. - Seal Draft Shield
Close and seal the three-door glass draft shield completely to isolate the weighing chamber from ambient air currents. - Initiate Internal Calibration
Press the one-key internal calibration button to trigger the automated calibration sequence, which compensates for temperature drift and mechanical errors. - Verify Calibration Status
Confirm the balance displays a stable zero reading and the calibration indicator shows completion before proceeding to sample weighing.
What performance trade-off exists between the two weighing ranges on the EB210G-0.1MG-D dual-range analytical balance?
The EB210G-0.1MG-D provides a 210 g range with 0.1 mg readability and a 32 g range with 0.01 mg readability. Repeatability and linearity are ±0.6 mg for the high-capacity range and ±0.06 mg for the semi-micro range, enabling sub-milligram precision only when operating within the lower capacity limit under strict environmental conditions.
What environmental and operational conditions are required to achieve reliable 0.01 mg semi-micro readings on the EB210G-0.1MG-D?
For 0.01 mg readability, the three-door glass draft shield must be fully sealed, and the balance must undergo a 30-minute pre-heating phase to allow the electromagnetic core to reach thermal equilibrium. The unit must also be leveled using the front bubble spirit indicator and micro-threaded leveling feet, as stated in the critical precision note.
How does the automated internal calibration on the EB210G-0.1MG-D maintain accuracy without external weight handling?
As an FA-series variant, the EB210G-0.1MG-D features one-key fully automated internal calibration triggered by timed schedule intervals or active ambient temperature fluctuations. This corrects mechanical measurement errors without requiring manual standard weight handling, ensuring traceable accuracy under changing lab conditions.
The EB210G-0.1MG-D dual-range analytical balance delivers semi-micro precision with rear-mounted EMFC sensor and automated internal calibration, yet demands a 30-minute warm-up and sealed draft shield for 0.01 mg resolution operation.
Positive
- Dual-range high precision weighing: Offers 210 g / 32 g capacity with dual readability (0.1 mg / 0.01 mg) enabling both micro and macro sample analysis on a single platform.
- Automated internal calibration system: Built-in one-key internal calibration triggered by timer or ambient temperature fluctuations eliminates manual weight handling errors for consistent accuracy.
Trade-offs
- Extended equilibration requirement: For 0.01 mg readability, a 30-minute system pre-heating phase and completely sealed draft shield are mandatory before calibration to achieve stable readings.
- Environmental sensitivity at high resolution: Semi-micro weighing (0.01 mg) requires full draft shield closure and stable ambient conditions; open air, drafts, or temperature gradients degrade measurement repeatability.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).