Electronic Analytical Balance 120g 0.1mg Lab ATOMFAIR®

$985.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

EB120G-0.1MG-I-01 analytical balance with 210g capacity, 0.1mg readability, ±0.1mg repeatability, RS232 output, and ≤2.5s stabilization. Order now.

SKU: AF-EI-B-ANLB-210A-IR01
Category: ,

Description

ATOMFAIR® EB120G-0.1MG-I-01 ELECTRONIC ANALYTICAL BALANCE

RESEARCH GRADE METROLOGY

Product Overview

The ATOMFAIR® EB120G-0.1MG-I-01 sets the industry benchmark for laboratory cell-to-cell consistency and baseline testing control. Engineered with a classic rear-mounted electromagnetic force restoration sensor, this series eliminates measurement variables during rigorous sample processing. Its distinctive split-type architecture decouples the high-brightness LED display unit from the weighting block, mitigating operational kinetic vibrations to ensure pure validation platform benefits. Optimized for ultra-low mass powder and fluid tracking up to 210g, it remains a premier infrastructure choice for premium analytical labs exploring high precision laboratory scale price options.

EB120G-0.1MG-I-01 Detailed Metrology Parameters

PARAMETER ITEM TECHNICAL SPECIFICATION DETAILS
Product Model EB120G-0.1MG-I-01
Product Classification Electronic Analytical Balance
Readability (d) 0.1mg
Maximum Capacity (Max) 210g
Repeatability Error ±0.1mg
Linearity Error ±0.2mg
Average Stabilization Time ≤2.5s
Initial Warm-up Duration 30~60min
Weighing Pan Dimensions Φ80mm
Draftshield Internal Width 230mm
Overall Physical Dimensions 470 × 310 × 330mm
Operating Ambient Temp 18°C~23°C
Operating Ambient Humidity 20%~80%RH
Power Supply Specifications Input: 220VAC 50Hz, Output: 12V/2A

Semi-Micro Analytical Balance Comprehensive Matrix

MODEL / PARAMETER EB31-120G-01MG-R EB51-120G-01MG-R EB82-120G-01MG-R EB31-210G-01MG-R EB51-210G-01MG-R EB82G-01MG-R-03 EB120-120G-01MG-R
Readability (d) 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg 0.01mg
Max Capacity (Max) 31/120g 51/120g 82/120g 31/210g 51/210g 82/210g 120g
Repeatability Error ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg
Linearity Error ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg ±0.02mg
Calibration Weight 10g 10g 10g 10g 10g 10g 10g
Stabilization Time ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s ≤2.5s
Preheat Duration 30~60m 30~60m 30~60m 30~60m 30~60m 30~60m 30~60m
Pan Size / Draftshield Φ80mm Stainless Steel Pan / 230mm Internal Chamber Safety Width
Dimensions / Environment 470 × 310 × 330mm Form Factor / 18°C~23°C Thermal Zone / 20%~80%RH Matrix
Power Parameters Unified Architecture: 220VAC 50Hz Stable Input, 12V/2A Pure DC Output

Electronic Analytical Balance Comprehensive Matrix

MODEL / PARAMETER EB120G-0.1MG-02 EB210G-0.1MG-01 EB220G-0.1MG-02 EB320G-0.1MG-01 EB120G-0.1MG-I-01 EB210G-0.1MG-I EB220G-0.1MG-I-02
Readability (d) 0.1mg Across Entire Configuration Family
Max Capacity (Max) 120g 210g 220g 120g 210g 220g 320g
Repeatability Error ±0.1mg Controlled Tolerance Threshold
Linearity Error ±0.2mg Linearity Correction Limit
Stabilization Time ≤2.5 seconds (Average Kinetic Interval)
Preheat Duration 30~60 minutes Baseline Core Setup
Hardware Form Factor Φ80mm Pan / 230mm Internal Chamber Width / 470 × 310 × 330mm Total Enclosure
Operating Conditions 18°C~23°C Regulated Temperature / 20%~80%RH / Input 220VAC, Output 12V/2A

General Matrix Specifications

GENERAL ATTRIBUTE STANDARD CONFIGURATION VALUES
Stabilization Time ≤2.5s (Average Operational Interval)
Initial Warm-up Duration 30~60min for Core Metrology Stabilization
Weighing Pan Dimension Φ80mm Stainless Steel Architectural Platform
Draftshield Chamber Width 230mm Anti-static Internal Space
Overall Form Factor 470 × 310 × 330mm Total Spatial Dimensions
Operating Ambient Temp 18°C~23°C Regulated Thermal Zone
Operating Ambient Humidity 20%~80%RH Non-condensing Atmospheric Matrix
Power Module Configuration Input: 220VAC 50Hz, Output: 12V/2A Stable DC Link

Key Features & Advantages

  • Rear-Mounted Electromagnetic Restoration: High precision and premium resolution architecture providing ultra-responsive, rapid, and drift-free mass detection kinetics.
  • Vibration-Isolated Split Design: Intelligently decouples the extensible high-definition LED panel from the core weighing mechanism, completely eliminating keystroke kinetic interference.
  • All-Around Structural Glass Shield: Seamless transparent protection block ensuring robust sample integrity, designed for tool-less removal and efficient sanitization cycles.
  • Advanced Intelligent Auto-Calibration: Fully automated alignment tracking loop triggered instantly upon thermal fluctuations >1.5°C or every 2 hours to eliminate ambient errors.
  • Multi-Mode Unit Transformation: Comprehensive onboard software supporting g, ct, oz, lb calculations paired with micro-addition scaling optimized for powder or liquid processing.
  • Bidirectional Data Synchronicity: Equipped with industrial RS232 communication interfaces for seamless integration with peripherals, PCs, and third-party LIMS environments.

APPLICATION SCOPE: High precision laboratory metrology, micro-powder tracking, fluid fraction control, and multi-unit scientific validation.
PACKAGING: Industrial shockproof high-density foam framing with isolated glass panels and customized power modular blocks.
IMPORTANT NOTICE: To secure uncompromised 0.1mg/0.01mg metrology performance, power up and allow the system to calibrate internally within the 18°C~23°C thermal zone for 30~60 minutes before verification.
TAILORED METROLOGY FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

The balance requires a regulated temperature environment of 18°C to 23°C and non-condensing humidity between 20% and 80% RH for accurate metrology. A 30 to 60 minute warm-up and proper vibration isolation are mandatory to achieve specified repeatability and linearity.

  • Ambient Temperature Range: Operate the balance only within 18°C to 23°C to prevent thermal drift.
  • Humidity Limit: Maintain relative humidity between 20% and 80% to avoid condensation and measurement errors.
  • Warm-up Period: Allow the balance to warm up for 30 to 60 minutes after power-on to stabilize the internal electronics.
  • Auto-Calibration Trigger: Automatic calibration is initiated when ambient temperature fluctuates more than 1.5°C or every 2 hours.
  • Vibration Isolation: Place the balance on a vibration-free bench to eliminate kinetic interference and ensure repeatability.

Initial setup requires careful attention to environmental conditions and warm-up procedures. Follow these steps to achieve the specified measurement performance.

Required Equipment: ATOMFAIR EB120G-0.1MG-I-01 Analytical Balance

  1. Place Balance on Stable Surface
    Place the balance on a vibration-free bench in a temperature- and humidity-controlled environment.
  2. Connect Power and Warm Up
    Connect the balance to a 220VAC power supply and allow it to warm up for 30 to 60 minutes.
  3. Verify Ambient Conditions
    Verify that the ambient temperature is between 18°C and 23°C and humidity is between 20% and 80% RH.
  4. Perform Auto-Calibration
    Activate the automatic calibration function or allow it to trigger upon thermal fluctuation or after 2 hours.

How does the 30–60 minute warm-up requirement affect measurement stability for the 0.1 mg readability, and can reliable data be collected before full stabilization?

The 30–60 minute warm-up is mandatory for core metrology stabilization; measurements taken before this period may not achieve the specified repeatability error of ±0.1 mg and linearity error of ±0.2 mg. The balance further compensates for ambient changes via intelligent auto-calibration, which triggers automatically upon thermal fluctuations >1.5°C or every 2 hours to maintain accuracy.

Can the EB120G-0.1MG-I-01 be integrated with a laboratory information management system (LIMS) and what data interface does it support?

Yes, the balance is equipped with an industrial RS232 communication interface that enables bidirectional data synchronicity, allowing seamless integration with PCs, peripherals, and third-party LIMS environments. This supports real-time data transfer for automated record-keeping and compliance.

What are the critical environmental and power infrastructure requirements for maintaining 0.1 mg accuracy with the ATOMFAIR EB120G-0.1MG-I-01?

The balance requires a regulated thermal zone of 18°C–23°C and non-condensing humidity between 20%–80%RH. Power input must be 220VAC 50Hz, with a 12V/2A stable DC output. The split architecture decouples the display from the weighing unit to eliminate keystroke vibrations, and the structural glass shield protects sample integrity.

The ATOMFAIR® EB120G-0.1MG-I-01 electronic analytical balance delivers 0.1mg readability with a 210g capacity, utilizing a rear-mounted electromagnetic force restoration sensor for drift-free mass detection and a split architecture that isolates the display from the weighing mechanism to eliminate keystroke vibrations. However, it requires a regulated 18°C–23°C thermal zone and a mandatory 30–60 minute warm-up period to achieve specified metrology stability.

Positive

  • Drift-free electromagnetic sensor: Rear-mounted electromagnetic force restoration provides ultra-responsive, rapid mass detection with minimal drift over time, ensuring consistent baseline measurements for micro-powder and fluid tracking.
  • Vibration-isolated split design: The high-brightness LED display unit is physically decoupled from the weighing block, eliminating kinetic interference from keystrokes and preserving measurement integrity during sample processing.

Trade-offs

  • Extended warm-up requirement: A 30–60 minute initial warm-up is mandatory before verification to allow the internal electronics and sensor to stabilize, adding setup time before routine use.
  • Narrow operating temperature range: Optimal performance is confined to 18°C–23°C; deviations outside this thermal zone may degrade repeatability and linearity, requiring climate-controlled laboratory infrastructure.