Analytical Balance 120g 0.1mg Touchscreen ATOMFAIR®

$1,435.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

External-calibration analytical balance with 120 g capacity, 0.1 mg readability, ±0.1 mg repeatability, Φ90 mm pan, RS232 output, and ISO 9001 build. Order now.

SKU: AF-EI-B-ANLB-120A-IR02
Category: ,

Description

ATOMFAIR® EB120G-0.1MG-01 TOUCHSCREEN ELECTRONIC ANALYTICAL BALANCE

RESEARCH GRADE MATERIAL

Product Overview

The ATOMFAIR® EB120G-0.1MG-01 Touchscreen Electronic Analytical Balance delivers cell-to-cell consistency, baseline testing control, variable elimination, and electrolyte validation platform benefits while nesting target touchscreen analytical balance price keywords. Engineered with a heavy-duty aluminum base and dual Metro protective user interface, this system eliminates ambient environmental variables during high-precision micro-gravimetric operations.

EB120G-0.1MG-01 Exclusive Specifications

PARAMETER DETAILS
1. Core Device & Electrochemical Design
Maximum Capacity 120 g
Readability 0.1 mg
Repeatability ±0.1 mg
Linearity ±0.2 mg
Pan Size Φ90 mm
Calibration Type External Calibration Model

Full Series Configuration Matrix

Model EB120G-0.1MG-01 EB120G-0.1MG-I-01 EB220G-0.1MG-01 EB220G-0.1MG-I-01 EB220G-1MG EB220G-1MG-I EB320G-1MG EB320G-1MG-I EB520G-1MG-01 EB520G-1MG-I
Max Capacity (g) 120 120 220 220 220 220 320 320 520 520
Readability (mg) 0.1 0.1 0.1 0.1 1 1 1 1 1 1
Repeatability (mg) ±0.1 ±0.1 ±0.1 ±0.1 ±1 ±1 ±1 ±1 ±1 ±1
Linearity (mg) ±0.2 ±0.2 ±0.2 ±0.2 ±2 ±2 ±2 ±2 ±2 ±2
Pan Size (mm) Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90 Φ90
Calib. Type External Internal External Internal External Internal External Internal External Internal
* Note: “C” suffix denotes Automated Internal Calibration systems; Standard models utilize External Calibration architectures. Processed under strict ISO 9001 compliance conditions.

Key Features & Advantages

  • TFT Full-Color Touch Interface: High-resolution true color liquid crystal display paired with double-glove sensitive touch operation maps perfectly to ergonomic laboratory environments.
  • Dual Metro Anti-Fatigue UI: Specifically engineered utilizing eco-friendly, optimized contrast matrices to reduce eye strain during extended verification campaigns.
  • Heavy-Duty Stabilized Chassis: Full aluminum architectural base dampens environmental low-frequency vibration, promoting uncompromised validation integrity.
  • Industrial Structural Safeguards: Equipped with premium display protective covers and structural glass-door transit shock locks to extend long-term system life-cycles.
  • Integrated Application Software: Factory preloaded with specialized metrology workflows and standard RS232 digital output ports for bi-directional data transfer to PCs and printers.

APPLICATION SCOPE: Analytical laboratory weight verification, institutional metrology, SCI-grade material R&D, and data validation metrics.
PACKAGING: Secure high-density foam container enclosure integrated with glass-door protection travel locks.
IMPORTANT NOTICE: This metrology system is highly sensitive to micro-gravitational drift. Ensure transit glass locks are completely disengaged before initiation, and calibrate within an isolated environment to maintain uncompromised performance.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

This analytical balance is sensitive to micro-gravitational drift and requires an isolated, vibration-free environment for accurate operation. Transit glass locks must be fully disengaged before use to prevent mechanical interference.

  • Vibration Sensitivity: The heavy-duty aluminum base dampens low-frequency vibration, but the system must be placed on a stable, isolated surface to maintain repeatability within ±0.1 mg.
  • Calibration Requirement: External calibration must be performed in an isolated environment to compensate for gravitational drift and ensure linearity within ±0.2 mg.
  • Transit Lock Disengagement: Structural glass-door transit shock locks must be completely disengaged prior to power-on to prevent mechanical binding and measurement errors.

This procedure ensures the balance is properly set up and calibrated for high-precision micro-gravimetric operations. Follow these steps to eliminate ambient environmental variables and achieve baseline testing control.

Required Equipment: External calibration weight set (appropriate for 120 g capacity), Anti-static mat or ionizer (optional, for dry environments)

  1. Disengage transit locks
    Verify and fully disengage all structural glass-door transit shock locks before powering on the balance.
  2. Place on stable surface
    Set the balance on a heavy, vibration-free laboratory bench in an isolated area free from drafts and direct sunlight.
  3. Power on and warm up
    Turn on the balance using the TFT touch interface and allow it to warm up for at least 30 minutes to stabilize internal electronics.
  4. Perform external calibration
    Select the external calibration mode from the touchscreen menu and follow the on-screen prompts using the certified calibration weight set.
  5. Verify repeatability
    Place a test weight on the pan three times and confirm that readings fall within ±0.1 mg of each other to validate calibration.

How does the external calibration requirement of the EB120G-0.1MG-01 impact measurement repeatability compared to internally calibrated models?

The EB120G-0.1MG-01 achieves ±0.1 mg repeatability and ±0.2 mg linearity using external calibration, which requires manual adjustment with standard weights. Internally calibrated models like the EB120G-0.1MG-I-01 automate this process, reducing drift risk from operator error or environmental changes. However, for stable, controlled laboratory environments, external calibration is sufficient to maintain the specified performance.

Can the EB120G-0.1MG-01 be directly integrated with existing laboratory data systems via RS232?

Yes, the balance includes a standard RS232 digital output port for bi-directional data transfer to PCs and printers. It is also preloaded with specialized metrology workflows. For integration with modern LIMS, an RS232-to-USB adapter may be needed since no USB port is specified. The RS232 protocol ensures reliable communication but may require configuration.

What specific startup procedures must be followed to avoid measurement errors on the EB120G-0.1MG-01?

The transit glass locks must be completely disengaged before initiation. The balance should be calibrated in an isolated environment to minimize micro-gravitational drift. The heavy-duty aluminum base dampens low-frequency vibration, but the system should be placed on a stable, level surface away from drafts and temperature fluctuations. The dual Metro protective UI helps reduce eye strain but does not affect measurement accuracy.

The EB120G-0.1MG-01 is a 120 g capacity, 0.1 mg readability external-calibration analytical balance with a heavy-duty aluminum chassis and TFT touch interface, designed for micro-gravimetric validation in controlled laboratory environments.

Positive

  • Heavy-duty aluminum vibration damping: The full aluminum architectural base dampens low-frequency environmental vibrations, promoting measurement stability during high-precision micro-gravimetric operations.
  • Dual Metro anti-fatigue touch UI: The TFT full-color display with double-glove-sensitive touch and optimized contrast matrices reduces operator eye strain during extended verification campaigns.

Trade-offs

  • External calibration required: This model relies on external calibration, requiring the user to manually apply certified reference masses, which adds procedural steps and potential for operator-dependent variability.
  • Sensitive to micro-gravitational drift: The system is highly sensitive to micro-gravitational drift; transit glass locks must be fully disengaged before use, and calibration must be performed in an isolated environment to maintain performance.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).