Precision Electronic Balance 500g 0.01g RS232 ATOMFAIR®

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

Laboratory electronic balance with 500 g capacity, 0.01 g readability, ±0.01 g repeatability, Φ130 mm pan, RS232 output, and ISO metrology. Order now.

SKU: AF-EI-B-PELB-500C-IR01
Category: ,

Description

ATOMFAIR® EB500G-0.01G-01 PRECISION ELECTRONIC BALANCE

LABORATORY GRADE METROLOGY INTERFACE

Product Overview

The ATOMFAIR® EB500G-0.01G-01 Precision Electronic Balance of the JY Series is engineered for high-stability analytical weighing, providing cell-to-cell consistency and robust error elimination across diverse laboratory testing workflows. Featuring optimized internal calibration matrices, the EB500G-0.01G-01 model serves as an ideal baseline verification platform for academic research and industrial quality validation, ensuring uncompromised data reproducibility.

Technical Specifications (JY5002)

PARAMETER DETAILS
1. Metrology & Core Design
Model Reference EB500G-0.01G-01Precision Interface
Maximum Capacity 500 g
Readability (d) 0.01 g
Repeatability ±0.01 g
Linearity Error ±0.02 g
Weighing Pan Form Factor Φ130 mm Stabilization Platform
2. Integration & Connectivity Parameters
Data Output Architecture Standard Integrated RS232 Serial Port
Power Supply Protocol Dual-source Configuration (AC/DC Matrix Compatible)
Manufacturing Rules Processed under strict ISO metrological standards for operational resistance

Full JY Series Cross-Reference Matrix

MODEL EB100G-0.01G-01 EB200G-0.01G-01 EB300G-0.01G-01 EB500G-0.01G-01 EB600G-0.01G-01 EB1000G-0.01G-01 EB2000G-0.01G
Max Capacity (g) 100 200 300 500 600 1000 2000
Readability (g) 0.01 0.01 0.01 0.01 0.01 0.01 0.01
Repeatability (g) ±0.01 ±0.01 ±0.01 ±0.01 ±0.01 ±0.01 ±0.01
Linearity (g) ±0.02 ±0.02 ±0.02 ±0.02 ±0.02 ±0.02 ±0.02
Pan Size (mm) Φ130 Φ130 Φ130 Φ130 Φ130 Φ130 Φ130


Key Features & Engineering Advantages

  • Ergonomic Minimalist Interface: Outfitted with an optimized streamlined chassis and high-contrast LCD screen for seamless parameters tracking.
  • Full-Range Tare & Parts Counting: Advanced firmware supports comprehensive multi-unit conversion and intelligent piece counting modes to eliminate variables during high-throughput validation.
  • Comprehensive Sensor Protection: Integrated hardware safeguards prevent transducer damage from sudden mechanical overloads or underload scenarios.
  • Metrological Diagnostic Array: Features automated fault-detection alerts alongside systematic zero-tracking indicators to safeguard laboratory data validation integrity.

APPLICATION SCOPE: High-precision analytical weighing, baseline data control, and mass-determination workflows in research-grade infrastructures.
STANDARD PACKAGING: High-resistance structural protective container with integrated user manual and calibrated power interface matrix.
IMPORTANT NOTICE: To prevent long-term degradation of structural resistance, avoid operating in high-vibration or extreme ambient temperature zones. Always verify stabilization metrics before capturing definitive phase or compound measurement thresholds.
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®

 

This document outlines the operational constraints and environmental requirements for the ATOMFAIR EB500G-0.01G-01 precision electronic balance. Adherence to these constraints ensures measurement accuracy and prevents instrument damage.

  • Environmental Operating Conditions: Operate the balance in a low-vibration environment with stable ambient temperature to prevent degradation of structural resistance.
  • Measurement Stabilization: Always verify that the balance has reached stabilization before recording weight measurements to ensure data reproducibility.
  • Overload and Underload Scenarios: The integrated hardware safeguards protect the transducer from damage caused by sudden mechanical overloads or underloads.
  • Metrological Diagnostic Array: Automated fault-detection alerts and zero-tracking indicators ensure data validation integrity during laboratory workflows.

How does the ±0.01 g repeatability of the EB500G-0.01G-01 balance affect measurement reliability for high-throughput quality validation workflows?

The ±0.01 g repeatability ensures cell-to-cell consistency and robust error elimination, making it suitable as a baseline verification platform for academic research and industrial quality validation. This specification, combined with the 0.01 g readability and ±0.02 g linearity error, supports uncompromised data reproducibility in high-throughput environments.

What are the data output and power supply integration requirements for the EB500G-0.01G-01 balance in a laboratory setting?

The balance features a standard integrated RS232 serial port for data output, allowing connection to external data logging systems. It supports a dual-source power configuration (AC/DC matrix compatible), enabling flexible integration with various laboratory power infrastructures.

What environmental conditions must be maintained to ensure accurate operation of the EB500G-0.01G-01 precision balance?

To prevent long-term degradation of structural resistance and ensure measurement accuracy, the balance should not be operated in high-vibration or extreme ambient temperature zones. Always verify stabilization metrics before capturing definitive phase or compound measurement thresholds, as indicated by the automated fault-detection alerts and zero-tracking indicators.

The EB500G-0.01G-01 provides 500 g capacity with 0.01 g readability, incorporating internal calibration matrices for repeatability and sensor protection against overloads, but requires stable vibration-free environments and mandatory stabilization verification before critical measurements.

Positive

  • Optimized internal calibration matrices: Cell-to-cell consistency and robust error elimination are achieved through internal calibration, ensuring uncompromised data reproducibility across analytical workflows.
  • Sensor protection and diagnostic array: Integrated hardware safeguards prevent transducer damage from mechanical overloads or underloads, while automated fault-detection alerts and zero-tracking indicators maintain measurement integrity.

Trade-offs

  • Environmental sensitivity to vibration and temperature: Operating in high-vibration or extreme ambient temperature zones can cause long-term degradation of structural resistance, requiring controlled lab conditions for reliable performance.
  • Mandatory stabilization verification before use: Users must always verify stabilization metrics before capturing definitive phase or compound measurement thresholds, adding a procedural step to ensure accuracy.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).