Electronic Analytical Balance 220g 0.1mg RS232 ATOMFAIR®

$897.00

Institutional Procurement & Supply Compliance: As a verified US supplier, Atomfair accepts formal institutional Purchase Orders (POs), contract billing schedules, and custom procurement loops for university and national laboratories, and corporate R&D departments globally.

EB220G-0.1MG-02 electronic analytical balance with 220 g capacity, 0.1 mg readability, ±0.1 mg repeatability, and ≤2.5 s stabilization. Order now.

SKU: AF-EI-B-ANLB-220A-ER02
Category: ,

Description

ATOMFAIR® EB220G-0.1MG-02 ELECTRONIC ANALYTICAL BALANCE

EB220G-0.1MG-02 CORE SPECIFICATION PLATFORM

Product Overview

The Atomfair® EB220G-0.1MG-02 Electronic Analytical Balance represents an advanced high-precision laboratory balancing platform integrated with high-sensitivity electromagnetic force compensation core sensors. Engineered with an optimized volumetric footprint and enhanced spatial air shielding, this analytical instrument satisfies demanding laboratory operations requiring fine mass determination down to 0.1 mg, delivering rapid baseline kinetic response stabilization within 2.5 seconds under rigorous scientific testing criteria.

EB220G-0.1MG-02 Target Model Specification Matrix

PARAMETER ITEM DETAILED MEASUREMENT PROFILE
1. Calibration & Metrology Parameters
Product Classification Electronic Analytical Balance
Readability Division Value (d) 0.1 mg
Maximum Scale Capacity (Max) 220 g
Repeatability Deviation Error ±0.1 mg
Linearity Deviation Error ±0.2 mg
Average Stabilization Response Time ≤ 2.5 Seconds
Mandatory Preheating Threshold 30 ~ 60 Minutes Following Power-on Initialization
2. Geometric Metrics & Volumetric Footprint
Weighing Pan Dimensions Φ 80 mm
Outer Structural Dimensions 470 mm × 310 mm × 330 mm
Draft Shield Internal Width 230 mm
3. Environmental Constraints & Electrical Architecture
Operating Environmental Temperature 18°C ~ 23°C
Operating Workspace Humidity 20% ~ 80% RH
Power Subsystem Profiles Global Grid Matrix Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Semi-Micro Analytical Balances Portfolio Comparison Matrix (B Series)

SPECIFICATION ITEM EB31-120G-01MG-R EB51-120G-01MG-R EB82-120G-01MG-R EB31-210G-01MG-R EB51-210G-01MG-R EB82G-01MG-R-03 EB120-120G-01MG-R
Readability Value (d) 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg 0.01 mg
Max Capacity Threshold (Max) 31/120g 51/120g 82/120g 31/210g 51/210g 82/210g 120g
Repeatability Deviation Error ±0.02 mg (Full Portfolio Standardized)
Linearity Deviation Error ±0.02 mg (Full Portfolio Standardized)
Typical Calibration Weight 10 g (External Reference Mass Threshold)
Stabilization Time (Average) ≤ 2.5 Seconds Dynamic Stabilization Response
Chassis Geometries & Sizes Pan Size: Φ 80 mm | Internal Draft Shield: 230 mm | Outer Body Structure: 470 × 310 × 330 mm
Operational Constraints Ambient Thermal Range: 18°C ~ 23°C | Workspace Moisture Matrix: 20% ~ 80% RH
Power Subsystem Architecture Global Grid Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Electronic Analytical Balances Portfolio Comparison Matrix (ES-E Series)

SPECIFICATION ITEM EB120G-0.1MG-02 EB210G-0.1MG-01 EB220G-0.1MG-02 EB320G-0.1MG-01 EB120G-0.1MG-I-01 EB210G-0.1MG-I EB220G-0.1MG-I-02
Readability Value (d) 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg 0.1 mg
Max Capacity Threshold (Max) 120g 210g 220g 120g 210g 220g 320g
Repeatability Deviation Error ±0.1 mg (Full portfolio Standardized)
Linearity Deviation Error ±0.2 mg (Full portfolio Standardized)
Stabilization Time (Average) ≤ 2.5 Seconds Optimized Processing Kinetics
Chassis Geometries & Sizes Pan Size: Φ 80 mm | Internal Draft Shield: 230 mm | Outer Body Structure: 470 × 310 × 330 mm
Operational Constraints Ambient Thermal Range: 18°C ~ 23°C | Workspace Moisture Matrix: 20% ~ 80% RH
Power Subsystem Architecture Global Grid Compliance Interface | Input: 220V AC / 50Hz | Output: 12V DC / 2A

Full Series Core Functional Advantages

  • Classic Rear-Mounted Electromagnetic Force Sensor: Delivers exceptional sensitivity, ultra-high resolution kinetics, and stable execution response times under rigorous data verification procedures.
  • Detachable Displaying Control Architecture (Split-Body Design): Isolates mechanical hand operation micro-vibrations from the foundational weighing block while facilitating multi-angle optical line-of-sight checks.
  • Extendable Angled LED Display Panel: Provides crystal-clear, high-brightness data visibility paired with an optimized UI layout to minimize user reading errors.
  • Panoramic Transparent Glass Draft Shield: Yields all-around tracking visibility of analytical specimens while utilizing advanced structural components for swift disassembly, cleaning, and decontamination.
  • Versatile Operational Weighing Modes: Supports robust native processing for standard weight measurement, trace percentage determination, and granular item piece counting.
  • Instantaneous Multi-Unit Conversions: Seamlessly transfers readouts between global scientific units including grams (g), carats (ct), ounces (oz), and pounds (lb) with zero manual math overhead.
  • Optimized Trace Micro-Addition Processing: Advanced micro-sampling digital filtering technology stabilizes data readouts against ambient drift, perfectly capturing minute powder or fluid specimen additions.
  • Integrated Bidirectional RS232 Communication Bus: Establishes standard hardware pipelines to micro-printers, lab host computer terminals, and third-party LIMS management systems.
  • Autonomous Fully Automatic Calibration Subsystem: Instantly triggers system recalibration if local temperature variations swing >1.5°C or if time elapsed exceeds 2 hours, drastically mitigating environmental error overhead.

APPLICATION SCOPE: Premium laboratory analytical target validation, analytical chemistry powder sampling, external calibration compliance workflows, and multi-series portfolio verification pipelines.
HIGH-EFFICIENCY HARNESS: Cost-effective design architectures highly optimized for analytical research institutes and institutional compliance laboratories.
IMPORTANT NOTICE: To preserve uncompromised operational resolution linearity, allow an initial warm-up threshold of 30-60 minutes following power engagement before performing operational zeroing, external calibration mass loading, or trace specimen additions.
TAILORED INDUSTRIAL LAB SOLUTIONS
Contact our elite laboratory engineering team for institutional bulk procurement quotes or interface custom integration.
EMAIL: INQUIRY@ATOMFAIR.COM
MANUFACTURER OPERATIONS: ATOMFAIR LLC INSTRUMENTS DIVISION
REGISTERED BRAND: ATOMFAIR®

This instrument requires a controlled environment with temperature between 18°C and 23°C and relative humidity between 20% and 80%. A mandatory preheating period of 30 to 60 minutes is required after power-on before any measurement operations.

  • Temperature Constraint: Operating ambient temperature must be maintained between 18°C and 23°C to ensure measurement accuracy.
  • Humidity Constraint: Relative humidity in the workspace must be kept between 20% and 80% to prevent moisture-related errors.
  • Preheating Requirement: Allow the balance to warm up for 30 to 60 minutes after power-on before performing zeroing or calibration.
  • Automatic Calibration Trigger: The balance automatically recalibrates if the ambient temperature changes by more than 1.5°C or if two hours have elapsed since the last calibration.

This procedure outlines the required steps to prepare the analytical balance for accurate measurement. Follow the sequence after power-on to ensure stable and repeatable results.

  1. Preheat
    Turn on the balance and allow it to preheat for 30 to 60 minutes without any load on the pan.
  2. Zero
    Press the tare/zero button to establish the zero reference point with the empty pan.
  3. Calibrate
    Place the appropriate external calibration mass on the pan and initiate the calibration routine per the instrument menu.
  4. Verify
    Confirm that the stabilization time is within 2.5 seconds and the displayed mass matches the calibrated value.

What is the practical significance of the ±0.1 mg repeatability deviation on the EB220G-0.1MG-02 balance for quantitative analysis?

The repeatability deviation of ±0.1 mg is identical to the readability division value (d=0.1 mg), meaning repeated measurements of the same mass will typically vary within that tolerance, which is standard for analytical balances at this precision level. This specification ensures reliable quantification in analytical chemistry powder sampling and external calibration workflows, as supported by the product's stated repeatability and linearity errors.

What specialized weighing modes are available on the EB220G-0.1MG-02 analytical balance?

The EB220G-0.1MG-02 supports standard weight measurement, trace percentage determination, and granular item piece counting. Additionally, it offers instantaneous multi-unit conversions between grams, carats, ounces, and pounds without manual calculation, as specified in the product's versatile operational weighing modes.

Why does the EB220G-0.1MG-02 balance require a 30-60 minute warm-up period and what are the consequences of skipping it?

The mandatory preheating threshold of 30-60 minutes following power-on initialization is necessary to stabilize the electromagnetic force compensation sensor and internal electronics for optimal resolution linearity. Skipping this warm-up can compromise operational resolution linearity, calibration accuracy, and trace specimen addition precision, as stated in the product's operational notice.

The EB220G-0.1MG-02 analytical balance offers 0.1 mg readability and ≤2.5 s stabilization with an automatic calibration subsystem that compensates for thermal drift, but requires a 30–60 minute warm-up and a controlled 18°C–23°C environment for reliable operation.

Positive

  • Fast stabilization ≤2.5 seconds: The balance achieves baseline kinetic response stabilization within 2.5 seconds, enabling high-throughput weighing workflows in analytical laboratories.
  • Automatic calibration drift compensation: The fully automatic calibration subsystem triggers recalibration when temperature shifts exceed 1.5°C or after 2 hours of operation, reducing environmental error and maintaining accuracy without manual intervention.

Trade-offs

  • Requires 30–60 minute preheating: A mandatory warm-up period of 30 to 60 minutes after power-on is necessary to achieve operational resolution linearity, delaying immediate use.
  • Narrow operating temperature range: The balance is specified for 18°C to 23°C ambient temperature, demanding a climate-controlled laboratory environment to avoid calibration drift and performance degradation.

Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.

To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.

Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).