Description
ATOMFAIR® EB220G-0.1MG-03 HIGH-PRECISION ANALYTICAL BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This analytical balance requires precise leveling on an anti-vibration surface and adequate pre-warming before operation. The integrated glass door transport lock must be engaged prior to any movement to prevent damage.
- Anti-Vibration Installation: The balance must be placed on a solid anti-vibration stone table to isolate parasitic low-frequency vibrations.
- Pre-Warming Requirement: The balance requires a pre-warming period to reach thermal equilibrium before conducting precision measurements.
- Leveling Procedure: The balance must be leveled using the four adjustable feet and integrated level indicator to ensure accuracy.
- Transport Lock Security: The glass door transport lock must be activated before any movement to prevent mechanical damage.
- Draft Shield Usage: The four-sided transparent glass draft shield must be closed during measurements to block cross-currents.
Follow these steps to correctly install and operate the analytical balance for accurate measurements. Proper leveling, pre-warming, and transport lock activation ensure reliable performance.
- Position on stable surface
Place the balance on a stable anti-vibration stone table to minimize external disturbances. - Level the balance
Level the balance using the four adjustable feet and built-in level indicator until the bubble is centered. - Pre-warm the device
Allow the balance to pre-warm for the manufacturer-recommended duration to achieve thermal stability. - Secure for transport
Activate the glass door transport lock before moving the balance to a different location to prevent mechanical damage.
How does the EB220G-0.1MG-03 balance its 0.1 mg readability with the risk of measurement drift caused by ambient vibrations and air currents?
The balance incorporates a solid full-aluminum base foundation and 4-level anti-shock adaptation to suppress low-frequency vibrations, combined with a four-sided transparent glass draft shield, aluminum alloy backplate, and an under-pan airflow breeze shield to block air currents. These features stabilize the measurement chamber, allowing the 0.1 mg readability to be maintained in typical laboratory environments without significant drift.
What sample size limitations apply to the EB220G-0.1MG-03’s Φ90 mm pan when performing routine micro-sample auditing?
The pan diameter is 90 mm, so samples or containers must be no larger than 90 mm in diameter to ensure stable placement and accurate weighing. Additionally, the maximum capacity is 220 g, so samples must be under that limit; the 0.1 mg readability is best suited for samples in the sub-milligram to low-gram range to maximize precision.
What mandatory preparation steps are required before operating the EB220G-0.1MG-03 to achieve its specified ±0.1 mg repeatability?
The balance must be completely leveled on an anti-vibration stone table and pre-warmed according to manufacturer specifications to stabilize internal electronics. The mechanical glass door transport lock must be engaged during relocation and only disengaged after the device is stationary. Auto zero-tracking calibration and smart fault diagnostics should be enabled to ensure baseline correction and operational reliability.
The EB220G-0.1MG-03 provides 0.1 mg readability with ±0.1 mg repeatability and a 220 g capacity, built with a vibration-dampening aluminum base and four-sided draft shield for stable micro-sample weighing, but requires a dedicated anti-vibration stone table, pre-warming before use, and strict transport lock engagement to maintain accuracy.
Positive
- Sub-milligram precision with anti-vibration design: 0.1 mg readability and ±0.1 mg repeatability are supported by a solid full-aluminum base foundation and 4-level anti-shock adaptation, effectively isolating ambient low-frequency vibrations for reliable trace sample measurements.
- Integrated draft and chamber protection: A four-sided transparent glass draft shield, aluminum alloy backplate, and under-pan breeze blocker secure the analytical chamber from cross-currents, while the mechanical glass door transport lock and dust guard ensure long-term mechanism integrity.
Trade-offs
- Mandatory leveled anti-vibration surface: The balance must be completely leveled on a dedicated anti-vibration stone table before operation; failure to do so compromises 0.1 mg repeatability and linearity.
- Pre-warm and transport lock requirements: The unit requires specified pre-warming before use, and the glass door transport lock must be engaged whenever the device is moved to prevent mechanical damage and calibration drift.