Description
ATOMFAIR® EB210G-0.1MG-R-03 DUAL-RANGE ELECTROMAGNETIC ANALYTICAL BALANCERESEARCH GRADE
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED SOLUTIONS FOR RESEARCH
Contact our engineering team for technical support or official institutional quotations.
EMAIL: inquiry@atomfair.com
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The balance requires a 30-minute pre-heating phase for the electromagnetic core to reach equilibrium before calibration. The three-door draft shield must be fully sealed for hundred-thousandth (0.01 mg) weighing routines to ensure ambient isolation.
- Pre-Heating Requirement: Allow a 30-minute system pre-heating phase to let the electromagnetic core reach full equilibrium prior to initializing calibration sequences.
- Draft Shield Sealing: For hundred-thousandth semi-micro weighing verification routines (0.01 mg), ensure the three-door draft shield housing is entirely sealed.
- Leveling Requirement: The balance must be leveled using the front-facing premium bubble spirit level indicator and heavy-duty micro-threaded leveling feet.
- Calibration Trigger Options: Automated internal calibration can be triggered by timed schedule intervals or active ambient temperature fluctuations.
- Ambient Drift Mitigation: Rear-mounted electromagnetic force compensation technology helps overcome subtle ambient drift during weighing.
Proper leveling, pre-heating, and draft shield sealing are critical for achieving 0.01 mg readability. The balance incorporates automated internal calibration triggered by time or temperature changes.
Required Equipment: Bubble spirit level indicator, Micro-threaded leveling feet, Three-door draft shield housing
- Level the balance
Level the balance using the front-facing bubble spirit indicator and micro-threaded leveling feet to ensure horizontal alignment. - Seal the draft shield
Close and seal the three-door draft shield housing entirely to isolate the weighing chamber from ambient air currents. - Pre-heat the balance
Allow the balance to pre-heat for 30 minutes to let the electromagnetic core reach full equilibrium before calibration or measurement.
When should I use the 0.01 mg readability range versus the 0.1 mg range on the EB210G-0.1MG-R-03, and what are the repeatability implications?
Use the 0.01 mg (hundred-thousandth) range for samples up to 120 g requiring semi-micro precision, but note that repeatability in this mode is ±0.06 mg. For samples up to 210 g, switch to the 0.1 mg range where repeatability is ±0.6 mg. The trade-off balances higher capacity against lower readability and tighter repeatability.
Can the EB210G-0.1MG-R-03 be integrated with a laboratory information management system (LIMS) via its RS232 interface, and what are the data logging capabilities?
Yes, the balance includes a standard RS232 digital output interface for automated computer logging or direct peripheral printing. While the source does not specify LIMS-native protocols, the RS232 bus supports high-fidelity data transmission for external logging loops. The balance also features fully automated internal calibration (timer- and temperature-triggered) to minimize manual intervention during integration.
What environmental and operational conditions are required to achieve the 0.01 mg semi-micro readability on the EB210G-0.1MG-R-03, and why is a 30-minute pre-heating phase necessary?
For 0.01 mg readings, the three-door glass draft shield must be entirely sealed to isolate the weighing chamber from air currents and ambient drift. A 30-minute system pre-heating phase is required to allow the electromagnetic core to reach full equilibrium before calibration. The balance also incorporates structural temperature compensation matrices to maintain stability under fluctuating lab conditions.
The EB210G-0.1MG-R-03 dual-range analytical balance offers a 210 g / 120 g capacity with 0.1 mg / 0.01 mg readability, leveraging rear-mounted EMFC technology for high-resolution weighing. Its automated internal calibration and draft shield housing support stable operation, but achieving 0.01 mg precision requires a 30-minute pre-heating phase and sealed enclosure, imposing strict environmental and procedural controls.
Positive
- Dual-range capacity with high readability: Provides 210 g / 120 g maximum capacity and 0.1 mg / 0.01 mg readability, enabling precise measurements across a wide mass range suitable for analytical and semi-micro applications.
- Automated internal calibration for drift correction: FA-series variant includes one-key fully automated internal calibration triggered by timed intervals or ambient temperature changes, reducing manual weight handling and compensating for thermal drift.
Trade-offs
- Requires pre-heating for semi-micro mode: To achieve 0.01 mg readability, the balance must undergo a 30-minute system pre-heating phase to allow the electromagnetic core to reach full equilibrium before calibration, extending setup time.
- Draft shield must be sealed for high precision: For hundred-thousandth (0.01 mg) verification routines, the three-door glass draft shield must be entirely sealed to isolate the sample from ambient air currents, limiting accessibility during weighing.
Every advanced material, component, equipment, and instrument in our catalog is backed by rigorous testing. We maintain strict internal quality management frameworks and align with CE conformity metrics to deliver transparent, reproducible performance data via our public open-science repository.
To request raw batch performance data, submit formal vendor registration paperwork, or execute a fast-turnaround R&D manufacturing loop, contact us at inquiry@atomfair.com.
Item is dispatched under the Atomfair Shipping & Delivery Framework (Free worldwide shipping on orders over $59 USD). Return is governed by the Atomfair Return & Refund Policy (7-day technical return window).