Description
ATOMFAIR® EB160G-0.1MG HIGH-PRECISION ANALYTICAL BALANCELABORATORY INSTRUMENT GRADE
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
TAILORED METROLOGY SOLUTIONS FOR RESEARCH
EMAIL: inquiry@atomfair.com
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Manufacturer: Atomfair LLC
Brand: ATOMFAIR®
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
This balance requires installation on an anti-vibration stone table with complete leveling before operation. Pre-warming the device according to manufacturer specifications is mandatory to achieve stated metrology performance.
- Leveling Requirement: The balance must be leveled using its adjustable feet and built-in level indicator to ensure accurate measurements.
- Pre-Warming Specification: Connect the power supply and allow the device to stabilize for the warm-up period defined in the user manual.
- Transport Lock Protocol: Engage the mechanical glass door transport lock before moving the balance to prevent internal damage.
- Draft Shield Integrity: Keep all draft shield doors and the under-pan breeze shield closed during weighing to secure the analytical chamber from air currents.
- Vibration Suppression: Place the balance on a solid full-aluminum base or dedicated anti-vibration table to suppress ambient low-frequency vibrations.
Follow these steps to safely initialize the balance for precise weighing. Proper environmental preparation and calibration are critical for accurate measurements.
Required Equipment:
- Level the Balance
Level the balance using the adjustable feet until the built-in level indicator confirms horizontal alignment. - Pre-Warm the Device
Connect the power supply and allow the balance to pre-warm for the time specified in the user manual before taking measurements. - Activate Transport Lock
Engage the glass door transport lock before moving the balance to prevent damage. - Calibrate Instrument
Perform zero-tracking calibration by pressing the tare button with the pan empty to ensure baseline accuracy. - Minimize Air Disturbance
Close the draft shield doors fully during weighing to isolate the chamber from air currents.
How does the 4-level anti-shock adaptation on the EB160G-0.1MG balance affect measurement repeatability for samples near 0.1 mg when environmental vibrations are present?
The 4-level anti-shock adaptation filters ambient low-frequency vibrations to maintain the ±0.1 mg repeatability specification even under moderate disturbance. Higher adaptation levels increase measurement stabilization time, trading speed for precision in noisy environments. The solid aluminum base foundation further suppresses parasitic vibrations, ensuring the 0.1 mg readability is retained for trace sample assays.
Is the EB160G-0.1MG analytical balance compatible with automated powder dispensing systems given its draft shield design and pan size?
The Φ90 mm pan and four-sided glass draft shield limit direct access for large dispensing heads, but the built-in below-balance underhook enables bottom-suspension weighing for custom automated setups. The tunable response speed can synchronize with dispensing rates to achieve the stated 0.1 mg readability. For reliable operation, the balance must be placed on a completely leveled anti-vibration stone table, as noted in the operational requirements.
What pre-operation procedures are mandatory to ensure the EB160G-0.1MG balance delivers its specified ±0.1 mg repeatability for trace chemical analysis?
The balance must be placed on a completely leveled anti-vibration stone table and pre-warmed according to manufacturer specifications before use. The glass door transport lock must be engaged when moving the unit, and the integrated dust guard protects the display during storage. These steps are essential to achieve the ±0.2 mg linearity error and ±0.1 mg repeatability stated in the technical specifications for micro-sample auditing workflows.
The Atomfair EB160G-0.1MG analytical balance achieves 0.1 mg readability with a multi-layer vibration suppression base and four-sided draft shield, enabling reliable trace sample quantification. Consistent operation requires placement on a leveled anti-vibration table and adherence to prescribed warm-up procedures.
Positive
- Multi-stage vibration suppression: A solid full-aluminum base, 4-level anti-shock adaptation, and tunable response speeds actively damp ambient low-frequency vibrations, preserving measurement stability for sub-milligram readings.
- Integrated cross-current shielding: A four-sided glass draft shield, aluminum backplate, and under-pan breeze blocker isolate the weighing chamber from airflow and thermal gradients, critical for 0.1 mg repeatability.
Trade-offs
- Requires dedicated anti-vibration table: The balance must be completely leveled on an anti-vibration stone table and pre-warmed per specifications before operation; suboptimal mounting compromises accuracy and repeatability.
- Mechanical transport lock mandatory: The glass door transport security mechanism must be activated before moving the unit; failure to do so risks damage to the draft shield and internal alignment.