Atomfair-AFS-MA369 Atomic Fluorescence-HPLC Speciation Analysis System: Seamless Compatibility, Multi-Mode Detection for Arsenic/Mercury/Antimony Speciation & Valence Analysis

The Atomfair LC-AFS Speciation Analysis System offers seamless LC docking, multi-functional easy operation, and accurate detection compliant with international standards. It tests As, Hg, Sb totals/speciations, with two cost-effective upgrade options for labs.

Description

 

Atomfair-AFS-MA369 Atomic Fluorescence – Liquid Chromatography Speciation Analysis System

Core Product Advantages

Flexible Upgrade & Seamless Connection: Adopt ICP-MS continuous sample introduction technology, no need to change the sample introduction method, and can achieve seamless connection with liquid chromatography of multiple brands. Only one docking module is needed to complete the efficient linkage between atomic fluorescence spectrometer and existing liquid chromatograph, giving full play to the effectiveness of existing laboratory analysis equipment, and expanding speciation analysis and detection capabilities with high cost performance.

Multi-functional Compatible Design: In daily work, the atomic fluorescence host can be independently used as a detector to accurately complete the total amount detection of elements such as arsenic (As) and mercury (Hg); the liquid chromatograph can also carry out conventional detection projects independently. When elemental speciation analysis is required, rapid combination can be achieved through the docking unit with flexible and convenient operation, meeting the diverse detection needs of the laboratory.

International Standard Compliance: Fully comply with relevant international testing standards, can accurately complete the detection and analysis of elemental speciation such as inorganic arsenic and organic mercury, and provide a strong guarantee for the international recognition of test results.

Applicable Test Items

It can accurately analyze different speciation and valence states of arsenic (As), mercury (Hg), antimony (Sb) and other elements in samples. Among them, inorganic arsenic is significantly more harmful to the human body than organic arsenic. This system can effectively distinguish and quantitatively detect such key speciation, meeting the strict testing requirements in food and other fields.

Core Technical Indicators

Element Element Speciation Minimum Detectable Amount (ng) Precision Analysis Time (min) Linear Range
Arsenic (As) As(III) ≤0.03 ≤3% <10 Three orders of magnitude
DMA ≤0.05 ≤3% <10 Three orders of magnitude
MMA ≤0.05 ≤3% <10 Three orders of magnitude
As(V) ≤0.5 ≤3% <10 Three orders of magnitude
Mercury (Hg) Hg(II) ≤0.01 ≤3% <10 Three orders of magnitude
MetHg ≤0.01 ≤3% <10 Three orders of magnitude
EtHg ≤0.02 ≤3% <10 Three orders of magnitude
Antimony (Sb) Sb(III) ≤0.5 ≤3% <10 Three orders of magnitude

 

If you’re interested, have any questions, or have specific customization requirements, please feel free to contact us at inquiry@atomfair.com.