Atomfair Brainwave Hub: Semiconductor Material Science and Research Primer / Semiconductor Characterization Techniques / X-ray Diffraction (XRD)
Single-crystal X-ray diffraction is a powerful technique for determining the atomic-scale structure of crystalline materials. The method relies on the interaction of X-rays with the electron density of a well-ordered crystal, producing a diffraction pattern that encodes structural information. The process involves several key steps: crystal mounting, data collection, and structure solution, each critical for obtaining accurate and reliable results.

The first step in single-crystal X-ray diffraction is the selection and mounting of a suitable crystal. The crystal must be of high quality, free from defects such as twinning or inclusions, and typically ranges in size from 0.1 to 0.5 mm. Larger crystals may absorb too much X-ray radiation, while smaller ones may not diffract sufficiently. The crystal is mounted on a thin glass fiber or a loop made of nylon or other polymer, often with the aid of an adhesive or cryoprotectant to stabilize it during data collection. For temperature-sensitive samples, the crystal may be cooled using a cryostream to reduce thermal motion and radiation damage. Proper alignment of the crystal on the diffractometer is essential to ensure that the rotation axis is perpendicular to the X-ray beam.

Data collection is performed using a diffractometer equipped with an X-ray source, typically a rotating anode or synchrotron, and a detector such as a charge-coupled device (CCD) or pixel array detector (PAD). The most common data collection strategy is the rotation method, where the crystal is rotated in small angular increments, usually 0.1 to 1.0 degrees, while the detector records the diffraction pattern at each step. This method ensures that a sufficient number of reflections are captured to reconstruct the reciprocal lattice. The exposure time per frame is optimized to balance signal-to-noise ratio and data collection duration, often ranging from a few seconds to several minutes depending on crystal quality and X-ray intensity.

During data collection, the diffractometer measures the intensity of each reflection, characterized by its Miller indices (h, k, l). The raw data consists of a series of images, each corresponding to a small rotation of the crystal. These images are processed to extract integrated intensities, which are corrected for factors such as background noise, absorption, and radiation damage. The result is a dataset of structure factor amplitudes, |F(hkl)|, which represent the scattering power of the crystal in different directions.

The next stage is structure solution, where the phase problem must be addressed. Unlike the measured intensities, the phases of the structure factors are not directly observable. Several techniques exist to overcome this challenge. Direct methods are commonly used for small molecules and involve statistical relationships between phases to iteratively reconstruct the electron density map. These methods rely on the Sayre equation and tangent formula to refine initial phase estimates. For larger or more complex structures, such as proteins, molecular replacement may be employed if a similar structure is known. This technique uses the known structure as a starting model to phase the new data.

Another approach is the use of Patterson maps, which are Fourier transforms of the squared structure factor amplitudes. Patterson maps reveal interatomic vectors and are particularly useful for locating heavy atoms in the presence of lighter elements. Once heavy atom positions are determined, their contributions can be used to phase the rest of the structure. Anomalous scattering, where atoms with significant absorption edges are incorporated into the crystal, can also provide phase information through differences in diffraction intensities at varying X-ray wavelengths.

After obtaining initial phases, an electron density map is calculated. This map represents the distribution of electrons within the unit cell and serves as the basis for model building. The atomic positions are interpreted from peaks in the electron density, and a preliminary structural model is constructed. This model is then refined using least-squares minimization to optimize the agreement between observed and calculated structure factors. Refinement adjusts atomic coordinates, displacement parameters, and occupancy factors to improve the fit. The quality of the refinement is assessed using metrics such as the R-factor and R-free, which measure the discrepancy between experimental and calculated data.

The final step involves validating the structure to ensure its correctness. This includes checking for reasonable bond lengths, angles, and torsion angles, as well as verifying that the electron density accounts for all non-hydrogen atoms. Hydrogen atoms, which scatter X-rays weakly, are often placed geometrically or located in difference Fourier maps if high-resolution data is available. The refined structure is then deposited in crystallographic databases for public access.

Single-crystal X-ray diffraction provides unparalleled detail about atomic arrangements, bonding, and intermolecular interactions. Its precision makes it indispensable in fields such as chemistry, materials science, and biology, where understanding structure-property relationships is crucial. The technique continues to evolve with advancements in X-ray sources, detectors, and computational methods, enabling the study of increasingly complex systems with higher accuracy and efficiency.
Back to X-ray Diffraction (XRD)