Atomfair Brainwave Hub: Nanomaterial Science and Research Primer / Characterization Techniques for Nanomaterials / Dynamic light scattering for nanoparticle sizing
Dynamic light scattering (DLS) has emerged as a critical analytical tool for characterizing the hydrodynamic radii of biomolecules, including proteins, antibodies, and nucleic acids. Its non-invasive nature and ability to measure particle size distributions in solution make it indispensable for studying biomolecular behavior under various conditions. A key advantage of DLS is its sensitivity to changes in hydrodynamic size, enabling researchers to monitor aggregation, conformational shifts, and intermolecular interactions in real time. Unlike techniques requiring fixed or dry samples, DLS provides insights into biomolecular dynamics in physiologically relevant environments.

Temperature-controlled DLS measurements are particularly valuable for investigating the thermal stability of biologics. By incrementally increasing temperature while monitoring hydrodynamic radius, researchers can identify unfolding transitions and aggregation onset points. For monoclonal antibodies, such studies reveal melting temperatures (Tm) and aggregation thresholds critical for formulation development. Nucleic acids, including DNA and RNA constructs, exhibit conformational changes under thermal stress that DLS can detect through shifts in apparent size. These measurements are often corroborated with circular dichroism or differential scanning calorimetry to correlate size changes with secondary structure alterations.

In biopharmaceutical development, DLS complements size-exclusion chromatography coupled with multi-angle light scattering (SEC-MALS). While SEC-MALS provides absolute molecular weight and oligomeric state analysis, DLS offers rapid assessment of hydrodynamic size without column separation. This is particularly useful for unstable or weakly interacting systems where SEC may induce shear-induced aggregation or disrupt transient complexes. DLS also excels in analyzing high-concentration protein formulations, where SEC limitations arise from viscosity effects and non-ideal elution behavior. The combination of DLS and SEC-MALS provides orthogonal verification of protein stability and aggregation propensity throughout drug development pipelines.

The measurement of hydrodynamic radius by DLS relies on the Stokes-Einstein equation, which relates diffusion coefficient to particle size. For proteins, this enables detection of subtle conformational changes that alter hydrodynamic drag. Antibody hinge region flexibility, for example, can produce measurable differences in apparent size despite minimal molecular weight variation. DLS sensitivity to these changes makes it valuable for comparing biosimilar candidates against reference products, where even minor structural variations may impact safety or efficacy.

Nucleic acid characterization presents unique challenges that DLS addresses effectively. The technique can distinguish between single-stranded and duplex forms, detect higher-order structures like G-quadruplexes, and monitor hybridization kinetics. Temperature ramping experiments reveal melting profiles where hydrodynamic radius increases as base pairing destabilizes. Such data inform the design of nucleic acid therapeutics by identifying stability thresholds under physiological conditions.

Advanced DLS applications include studying biomolecular interactions through changes in mutual diffusion coefficients. Protein-protein or protein-nucleic acid complex formation typically increases the hydrodynamic radius proportionally to the stoichiometry of interaction. This approach has been used to characterize antibody-antigen binding, ribosome assembly, and protein-nanoparticle conjugate formation. The technique's low sample consumption makes it suitable for precious clinical or research samples where material availability is limited.

Recent instrumental advancements have improved DLS performance for biological applications. Automated temperature control systems now achieve precision better than 0.1°C, essential for reproducible thermal unfolding studies. Enhanced detector sensitivity allows analysis of dilute samples, while advanced algorithms better discriminate between small populations of aggregates in predominantly monodisperse systems. These improvements have expanded DLS utility in quality control environments where detection of trace aggregates is mandatory for regulatory compliance.

The pharmaceutical industry employs DLS at multiple development stages. Early-stage candidate screening uses DLS to identify aggregation-prone molecules before committing resources to extensive development. During formulation optimization, DLS monitors excipient effects on protein stability. Lot-release testing may include DLS to verify product consistency, particularly for biosimilars where demonstrating comparability is essential. The technique's rapid analysis time—typically minutes per measurement—makes it suitable for high-throughput screening applications.

Despite its advantages, DLS has limitations that require careful experimental design. Polydisperse samples can complicate data interpretation, as the technique's intensity weighting overemphasizes larger particles. For this reason, DLS results are often validated with number-weighted techniques like nanoparticle tracking analysis when characterizing mixed populations. Sample preparation is critical, requiring thorough clarification to remove dust or large aggregates that could dominate the scattering signal. Appropriate buffer matching is essential to prevent light scattering artifacts from refractive index mismatches.

Future directions for DLS in biomolecular analysis include integration with microfluidic platforms for continuous monitoring of bioreactor products and coupling with other characterization methods in hyphenated systems. The development of advanced correlation algorithms may improve resolution of heterogeneous mixtures, while miniaturized DLS systems could enable point-of-care diagnostic applications. As biologic therapeutics grow more complex—encompassing multi-specific antibodies, gene therapies, and viral vectors—DLS will remain a vital tool for ensuring product quality and understanding molecular behavior in solution.

The technique's versatility across biomolecular classes and experimental conditions ensures its continued relevance in both academic research and industrial applications. From fundamental studies of protein folding to quality control of next-generation therapeutics, DLS provides essential information about hydrodynamic size that complements other biophysical methods. Its non-destructive nature allows repeated measurements on valuable samples, while temperature-controlled capabilities enable detailed stability profiling. As the field of biologics advances, DLS will adapt to meet new characterization challenges through ongoing instrumental and methodological refinements.
Back to Dynamic light scattering for nanoparticle sizing